User's Manual

RMON 127
Reference for the Business Policy Switch 2000 Management Software
Figure 64 RMONControl, Insert History dialog box
3 Select the port from the port list or type the port number.
4 Set the number of buckets.
The default is 50.
5 Set the interval.
The default is 1800 seconds.
6 Type the owner, the network management system that created this entry.
7 Click Insert.
Table 48 History tab fields
Field Description
Index A unique value assigned to each interface. An index identifies an
entry in a table.
Port Any Ethernet interface on the device.
BucketsRequested The requested number of discrete time intervals over which data is to
be saved in the part of the media-specific table associated with this
entry.
BucketsGranted The number of discrete sampling intervals over which data is saved
in the part of the media-specific table associated with this entry.
There are instances when the actual number of buckets associated
with this entry is less than the value of this object. In this case, at the
end of each sampling interval, a new bucket is added to the
media-specific table.