5.6 COMMUNICATION
This was discussed briefly in the section under “REGISTER SELECT” and will be fully explained here. When you choose
your register type under the REGISTER SELECT menu, this automatically formats the VSI-Pro Max to the appropriate
settings needed to communicate with your register. There may be times when you will need to amend these settings for
a specific register.
To access the Communication menu, press the “Up” or “Down” button to move the cursor to “COMMUNICATION” and
press “Set”. The following menu will appear:
INTERFACE TYPE
Choices: RS-232, PASSIVE TAP, RS-485
To set the interface type for your particular device, press the “Up” or “Down” button to move the cursor to “INTERFACE
TYPE” and press and release “Set”. The cursor will start flashing. You can now use the “Up” or “Down” button to make
your selection. When your selection appears, press “Set” again. The cursor will stop flashing and you can proceed to the
next menu item for programming. RS-232 and RS-485 are defined by IEEE standards, however, the Passive Tap is a high
impedance (100K) input with full diode protection. Refer to Table 1&2 Pg. 12, for respective pin-outs of RS-232 or RS-485.
RX BAUD RATE
Choices: AUTO, 1200, 2400, 4800, 9600, 14.4K, 19.2K, 28.8K, 38.4K, 57.6K, 115.2K
To set the baud rate for your particular device, press the “Up” or “Down” button to move the cursor to “RX Baud Rate” and
press “Set”. The cursor will start flashing. You can now use the “Up” or “Down” button to make your selection. When your
selection appears, press “Set” again. The cursor will stop flashing and you can proceed to the next menu item for
programming.
Figure 150: Register Settings Sub-Menu
VSI-Pro Max POS / Cash Register Interface
INTERFACE TYPE RS-232
RX BAUD RATE AUTO
TX BAUD RATE AUTO
TX PROTOCOL ASCII
PARITY NONE
DATA BITS 8
HW HANDSHAKING OFF
SW HANDSHAKING NONE
AUTO LINEFEED ON
EXIT
Figure 149: COMMUNICATION Sub-Menu
The “Register Settings” selects and allows you to program the communication and protocol parameters used to commu-
nicate with the POS or Cash Register using the DB9 connector. The “Network Settings” selects and allows you to
program the communication and protocol parameters used to network the VSI-Pro Max to other units using the AVE RS-
485 Network via the RJ45 connectors.
5. PROGRAMMING
REGISTER SETTING
To access the Register Setting menu, press the “Up” or “Down” button to move the cursor to “REGISTER SETTING” and
press “Set”. The following menu will appear:
REGISTER SETTINGS
NETWORK SETTINGS
NETWORK PROGRAM
NETWORK MASTER RESET
EXIT