User manual
Installation
1 - 6 ADPRO FastTrace, Issue 5
INPUT-OUTPUT
• GP SERIAL 1 - (9-pin D - Male) - RS-232 serial port with maximum 38,400 bps data rate
• GP SERIAL 2 - (9-pin D - Male) - RS-232 serial port with maximum 38,400 bps data rate
• PTZ - (9-pin D - Male) - RS485, for connection to camera stations. Protocol is dependent on the camera
station type and model
• DATA - (9-pin D - Male) - RS-232 data port with a maximum 57,600 bps.
• IN/OUT - (15-pin screw)
• EE - Export Evidence (not used in current version)
• A/S - Access / Secure input to control the remote dialling capability
• CLK - (not used in current version)
• SPARE - Spare
• MOD SEL - Mode Select input to switch operational mode via hardware
• FLT - Fault Relay output - COM, N/O and N/C contacts
• ALM - General Alarm Relay output - COM, N/O and N/C contacts
AUDIO
The AUDIO connector - (9-pin screw) is used to connect to local audio equipment.
• OUT - Line Output with 600Ω impedence
• IN - Line Input with 6KΩ impedence
• SPKR +/- - Local connection for 8Ω speaker
• MIC +/- - Local connection for 600Ω microphone
AUDIO SWITCHER connector - (15-pin D - Male) - Channel select outputs for control of the ADPRO VM22A Audio
Switcher unit.
ALARM and CONTROL
The ALARM INPUT - (15-pin screw) connectors supports direct alarm device connections.
• Up to thirty (30) external Alarm Inputs can be connected (20 only on Model 5010 and Model 5005). Inputs
can be programmed (via a setup menu) to trigger an alarm on either open or closed contacts
The CONTROL OUTPUT - (15-pin screw) connectors supports direct alarm device connections:
• Twenty (20) Control Outputs (10 only on Model 5010 and Model 5005) low power open drain transistor
outputs. For high power/voltage equipment, suitable interface circuitry must be used
POWER
IEC 3-pin connector for use with 115 V - 230 V AC, 47 - 63 Hz input power. Maximum input current is 5 amps.
Typical unit power consumption when fully optioned is 100 W.