User manual

Installation
ADPRO FastTrace, Issue 5 1 - 7
CONFIGURATION SWITCH
Figure 1-2 - Configuration Switch Settings
1.5 System Wiring Considerations
1.5.1 Electromagnetic Compatibility (EMC) Issues and Instructions
When an ADPRO FastTrace system is installed in accordance with the recommendations and procedures in this
manual, it will meet the EMC requirements of:
EN 55022 / AS3548 Class A, and FCC Part 15 Class A digital devices in respect to emissions, and
EN 50130-4 Alarm Systems Immunity.
To ensure EMC compliance for your system installation, make sure of the following:
CAT-5 Unshielded Twisted Pair (UTP) Data Cable is used for the Network port connection,
RG-59 coaxial 75ohm Video cable is used for all composite video connections and the cables are
terminated with 75 ohm BNC connectors, and
Where possible, all cables should be shielded (single or dual) twisted pair and the shield itself, along with
the associated drain wire, terminated at the ADPRO FastTrace with a connection to the chassis.
Note that the foil used in some shielded cable is only insulated on one side. Always check the foil shield with an ohm-
meter and make sure that the conductive side is in contact with shield termination recommendations in this manual.
P73 config switch.cdr
(8) PTZ PORT TERMINATION
ON = 120 ohm terminationRS485 with
OFF = RS485 without termination
(5) PTZ PORT ELECTRICAL INTERFACE
ON = RS422
OFF = RS485
(7) COMMS 2 PORT OPERATION
ON = DIRECT CONNECT
OFF = NORMAL
(10) VIDEO STANDARD
ON = RS170 (NTSC)
OFF = CCIR (PAL)
(12-11) Factory Set
ON, ON
(4) Factory Set
OFF
(1-3) Factory Set
OFF, ON, OFF
1234 56789101112
ON
***
*
NOTE - Factory setting - DO NOT change
(9) GP Serial 2
ON=ATM
OFF = Debug
(6) Factory Set
OFF
* *