User manual

Installation
ADPRO FastTrace, Issue 5 1 - 19
Figure 1-9 - External Relay - Typical output circuit
1.15 Mode Select Input
The way an ADPRO FastTrace operates its recording and alarm handling features can be changed by using up to four
(4) different operating ‘modes’. The parameters that define a particular mode of operation, such as recording rate and
alarm responses, are configured by using the FastTrace User Settings Menu.
From the FastTrace User Settings Menu, any two (of the four) operating modes can be assigned to activate depending
on the open/closed state of the Mode Select input pin.
When the Mode Select pin is ‘open’ (or ‘high’), the ADPRO FastTrace operates by using the mode parameters
assigned to that pin state. Placing a ‘closed contact’ on the pin switches the unit into an alternate mode.
Please refer to Section 2.3.4.4.2 for more information on operating modes.
1.16 Access/Secure Input
ADPRO FastTrace operation by default is in the Secure state and will respond to an Alarm Input by dialling/
connecting a remote user. The Access/Secure input allows the ADPRO FastTrace to be independently set into the
Access state of operation. This input is usually connected to an alarm panel or access control system. In the Access
state, trigger conditions on an Alarm Input may not cause a dial out depending on the programmed event response
behaviour. For example, during business hours a remote site may be placed into the Access state when its local security
system is deactivated, but will revert to the Secure state after hours.
When the Access/Secure input pin is ‘open’ (or ‘high’), the ADPRO FastTrace operates in the Secure state. Placing a
‘closed contact’ on the pin (i.e. shorting to Ground) switches the unit into the Access state.
NOTE
An ADPRO FastTrace may be (remotely) placed into the Access or Secure state by
the ADPRO Video Central User Interface. This action is independent of the signal level on
the Access/Secure pin. After such a ADPRO Video Central over-ride, the access/secure
input on the ADPRO FastTrace is ignored until the ADPRO Video Central disconnects.
Subsequent changes of state in teh Access/Secure input will be recognised by the
ADPRO FastTrace.