User manual

Setup
ADPRO FastTrace, Issue 5 2 - 3
2.1 Power Up
The green Power and the red Status LED’s on the front panel are lit as soon as power is applied to the unit. The
ADPRO FastTrace immediately starts to perform internal tests to ensure both software and hardware integrity. While
the internal tests are executing, the Fault Relay is de-energised and the red Status LED is lit, or flashing. The Status
LED will be ON during the initial stages of bootup then start flashing when the system is being initialized. This will
allow the user to ascertain if the unit is in system initialization stage or if a fault is present that will prevent the system
from correct operation.
A successful self-test ensures all diagnostic tests have been passed and to confirm this, the red Status LED goes off
and the Fault Relay is energised.
If the self-test fails, the red Status LED remains ON
If the power fails, the green Power LED will be OFF
If the diagnostic tests fail repeatedly, please contact your ADPRO supplier.
2.2 Access to the User Settings Menu
User Settings menus are provided to quickly and easily configure the ADPRO FastTrace for operation. The menus and
any associated stored parameters are held within non-volatile memory.
There are two ways of accessing and viewing the User Settings Menus.
1) Locally, by direct connection to a PC running ADPRO Video Central Lite software.
2) Remotely, by using a communications link to connect on-line to a PC running the Video Central Lite
software.
NOTE
The self-test function may take a few minutes to complete. During this period, any display
on the local monitor screen is not meaningful and should be ignored.
NOTE
After a local or remote connection has been established, to ensure that the latest version
of the User Settings program is used, the Video Central Lite software will negotiate with the
ADPRO FastTrace to check the Setup software revision level. If the ADPRO FastTrace has
a later version (than that of Video Central Lite), then Video Central Lite will download the
later version from the ADPRO FastTrace.