User manual

Setup
ADPRO FastTrace, Issue 5 2 - 9
2.2.1.1.5 Setting the Operational Parameters:
The ADPRO FastTrace is factory configured with typical operating values, but to use the ADPRO FastTrace in an
operational environment, its configuration must be modified to use the site names, phone numbers or network
addresses that match the real network. Once the ADPRO FastTrace settings have been configured, ADPRO Video
Central Lite settings must be updated to match.
2.2.1.1.6 Setting the ADPRO Video Central Lite Telephone (Dial-up) Connection
The basic information needed to use a telephone (dial-up) connection is entered via the Database / Administration /
Configure Sites menu:
Site ID 9 characters (max)
CMS Password 8 characters (max)
Modem Type Select from the list (Note different modem types must be installed via the Windows
Control Panel)
Once the basic connection details have been configured and saved, the ADPRO FastTrace is ready to connect via the
operational network.
2.2.1.1.7 Video Central Lite Settings for a Network Connection
The ADPRO Video Central Lite software will require some basic information in order to connect to any ADPRO
FastTrace site via a network connection. The minimum information that must be configured in each ADPRO FastTrace
is shown below.
To enter the information, go to Database / Administration / Configure Sites then select the Edit option.
Site ID 9 characters (max)
CMS Password 8 characters (max)
Transmitter Type FastTrace
Communications Network
IP Address The TCP/IP network address assigned to each ADPRO FastTrace (this address is
normally assigned by the network manager)
NOTE
The setup program will not allow invalid parameters to be saved. For example, should
you receive a message asking for a correct Ethernet Gateway address to be entered,
either enter the correct value or delete the invalid entry.