User manual

Setup
ADPRO FastTrace, Issue 5 2 - 19
2.3.2.2.9 Enable PAP
Factory Default: No
Set this checkbox to enable Password Authentication Protocol. PAP will authenticate the remote system during the
PPP negotiations. The valid username and password are defined by the fields of PPP Username and PPP Password.
2.3.2.2.10 PPP Username
Option: 20 characters maximum.
The Username (or Site Name) that will be provided by PPP when negotiating a serial IP connection. It is only required
when PAP is enabled.
2.3.2.2.11 PPP Password
Option: 20 characters maximum.
The Password that will be provided by PPP when negotiating a serial IP connection. It is only required when PAP is
enabled.
2.3.2.2.12 Nominal Data Rate (bits/sec)
Options: 8Kbps, 16Kbps, 32Kbps, 64Kbps, 128Kbps, Auto Detect.
Factory Default: Auto Detect
The Nominal Data Rate option is used by the ADPRO FastTrace to maximise the data rate on the communication
link. It is different from the β€˜Data Rate’ setting for the Modem /TA, in that ADPRO FastTrace attempts to send data
at the specified nominal data rate at all times. This option helps to provide consistency in the image transmission time
of the system, especially when the line quality of a communications link is unknown.
The Nominal Data Rate should be set to either auto detect or to the known speed of the communications network. For
example, use the β€˜128 kbps’ option when connected via a Basic Rate ISDN line.
NOTE
The PPP Username is a function of the modem or TA and will need also to be set in
the device.
NOTE
The PPP Password is a function of the modem or TA and will need also to be set in
the device.