Setup
2 - 20 ADPRO FastTrace, Issue 5
2.3.2.3 Advanced Communication Properties
Base Port Number:
Options: <value> Range is 2049 to 65536
Factory Default 15000
The Advanced Communication Properties option defines the Base Port Number used for communications with the
PC running ADPRO Video Central Lite software.
The default value = 15000 and should not be changed unless a conflict occurs due to a network connection of other
third-party equipment.
2.3.2.3.1 Call List
The Call List options are used to configure a list of (ADPRO Video Central Lite) sites that the unit will attempt to
contact when an alarm is triggered. Selecting Call List displays the menu shown in Figure 2-7.
Figure 2-7 - Call List menu
WARNING
If the Base Port Number is changed, then all ADPRO FastTrace units and
ADPRO Video Central Lite must be changed to the same value. Failure to do this on all
communicating systems will result in communications failure.