2.3.3.5.7.3 Hold Time
Options: When active, 2 sec, 5 sec, 10 sec, 30 sec, 60 sec.
Factory Default: 10 seconds
When there is a requirement that two (related) alarm inputs must be active before an alarm is activated (known a double
knock alarm activation), the Hold Time option sets the time ‘window’ for the second alarm input to occur.
If the second alarm input is not activated within the Hold Time period, no alarm event will be generated. Choose the
value most suited to the alarm activation requirement.
2.3.3.5.7.4 Camera View Style for the Triggered Alarm
Options: Live, Quad.
Factory Default: Quad
When an alarm is triggered by these contacts, the style of display configuration shown on ADPRO Video Central Lite
can be preset.
2.3.3.5.8 Control Outputs
The Control Outputs option defines a number of parameters about the type and operation of the output circuits
connected to the ADPRO FastTrace. The outputs are ‘open drain’ transistor circuits used to generate a control signal
(upon activation of an alarm) to activate third-party equipment at the remote site, for example a boom gate controller
or a floodlight control device. Refer to Section 1.14 for details of the hardware connector.
Select the Control Output number from the displayed list. The number of Control Outputs available will depend on the
ADPRO FastTrace Model number. The status of a Control Output is shown by a small icon to the left.
A Control Output is free when the ‘empty’ icon is shown next to the number
•The Connect button is used to enable a Control Output. A green tick is shown and details can be modified
To temporarily disable the use of a Control Output, the Disconnect button is used and a red cross is shown.
For example, set Disconnect if maintenance is being performed on the unit under control
NOTE
If the alarm input activates multiple times within the hold time period, only one
alarm will be reported.