User manual

Setup
ADPRO FastTrace, Issue 5 2 - 37
Figure 2-12 - Control Output Settings Menu
When the Configure button is used, the following settings can be made.
2.3.3.5.8.1 Control Output Name
Option: 16 characters maximum.
Enter the 16 character name to associate with this output. The name can be displayed when viewing video from a
camera input associated with this control output.
2.3.3.5.8.2 Default State
Option: Normally Open, Normally Closed
Default: Normally Open
Defines the operational state of the Control Output when not asserted.
When set for ‘normally closed’, the Control Output is shorted to ground via the output transistor.
2.3.3.5.8.3 Manual Operation
Select the Manual Operation Check Box to configure the Control Output for manual (remote user) use only. When
selected, the ability for the ADPRO FastTrace to automatically initiate a Control Output from an event condition is
disabled.
Note that this option must be set to allow remote users access to the Control Output function.