Instruction manual

Press the Arrow key to move the cursor or change the configurations Press the Enter key to
select or save the configurations.
IP Address/Subnet Mask/Gate Way/Port
Set IP Address , Subnet Mask , Gate Way and Port for receiving the UDP message
from Micros Workstations.
TX Baudrate
You can change Baudrate for the serial port to the DVR or PC to receive the data from
TCPIP232. There are choices1200/2400/4800/9600/14400/19200/28800/38400/57600/
115200 BPS for 8-bit non parity and 1 Stop bit.
Output Type
There is ASCII and VSI-ADD format for RS232 output that sends the data to the DVR
or PC. If you select ASCII the data output will be text and end with Carriage Return and Line
Feed. If you select VSI-ADD the data output will be leading with ESC , Address , Text and end
with Carriage Return this use for the DVR that support VSI-ADD protocol for Text Insertion.
Workstations Settings
You can use Micros Workstations up to 16 units to send UDP message to TCPIP232
by enable in front of Workstation Number and you can change the Workstation Number.
TCPIP232 Micros VSS 3700 Setups
The TCPIP232 Micros VSS 3700 is able to set the configurations by connecting the
RS-232 port to a PC or Laptop with TCPIP232-DVR/PC cable(021-037-SF). Run the serial
communications program at baudrate 19200,8,n,1 with VT100 emulation. Press ESC key
(1BH) , [ (5BH) and P (50H) to enter to the Main Menu of the TCPIP232 VSS 3700. If the
TCPIP232 starts listening to a UDP message you can not enter programming mode until
reboot the system again so disconnect all LAN cables prior to selection.
38
TCPIP232 Micros VSS 3700
* IP Address 192.168.0.233
- Subnet Mask 255.255.0.0
- Gate Way 192.168.1.1
- Port 12345
- TX Baudrate 19200
- Output Type VSI-ADD
- Workstations Settings
- Exit