6X16 DVI Matrix Switch User’s Guide Model SW-DVI-16X16 © 2008 Avenview Inc. All rights reserved. The contents of this document are provided in connection with Avenview Inc. (“Avenview”) products. Avenview makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice.
Table of Contents Section 1: Getting Started ...................................................................................................................... 4 1.1 Important Safeguards ............................................................................................................ 4 1.2 Safety Instructions ................................................................................................................. 4 1.3 Regulatory Notices Federal Communications Commission (FCC) ....
www.avenview.
Section 1: Getting Started 1.1 Important Safeguards Please read all of these instructions carefully before you use the device. Save this manual for future reference. What the warranty does not cover Any product, on which the serial number has been defaced, modified or removed. Damage, deterioration or malfunction resulting from: Accident, misuse, neglect, fire, water, lightning, or other acts of nature, unauthorized product modification, or failure to follow instructions supplied with the product.
1.4 Introduction Avenview SW-DVI-16X16 Matrix Switch is specially designed for switching 16 DVI input signals to 16 DVI outputs. It is ideal for applications that need DVI operation, such as big screen TV, TV education, TV and Telephone conference, multimedia meeting room etc. - 1.
Section 2: Installation Follow these instructions for installation of SW-DVI-16X16: 1. 2. 3. 4. Mount or fix the SW-DVI-16X15 safely Connect the SW-DVI-16X16 to included external power supply (50Hz 200V) through the power cable If controlling the SW-DVI-16X16 through RS232 port then connect the included RS232 serial cable Connect RJ45 cable to SW-DVI-16X16 This equipment should be used in a main power system with a grounded (neutral) conductor.
2.1.3 Lock or Unlock the Panel If the panel is locked, press the LOCK button will unlock the panel or if panel is locked then press the LOCK button to unlock it. The LED display will show lock or unlock status as shown in the figure below. 2.1.4 Switch Input Channel to Output Channel If the panel is locked, the device will have a bell warning when I/O button is pressed. Or if the panel is unlocked, the LED displays the I/O menu as shown in the figure below.
LOCK the panel when finished setting the channel. Example 2: Turn OFF Output Channel 15 1. 2. 3. 4. Unlock the panel if the panel locked Select operation format Select output channel Set input channel to be “OFF” in the same way as selecting input channel. Then finish to off output channel 15,and the LED displays as shown in figure below. LOCK the panel when finished setting the channel. 2.1.
Example: Load Macro 3 1. 2. 3. 4. Unlock the panel if it is locked Move cursor to ① to select operation format Move cursor to ② to select Macro number. Move cursor to ③ to load Macro 3 content to the device, the LED display is as the following figure 9. LOCK the panel if finished setting the Macro Example: Load Macro 3 1. 2. Unlock the panel if it is locked Select Macro Number: Move cursor to ① to select the macro number to be viewed through the MACRO and Enter button. 3.
2.1.6 1. Test Signal Board The output resolution is up to the two bits of DIPs on the test signal board. DIPS OFF OFF ON ON BIT 1 OFF ON OFF ON BIT2 Output Resolution: 1600x1200x60Hz Output Resolution: 1280x1024x60Hz Output Resolution: 1280x960x60Hz Output Resolution: 1152x864x75Hz 2. Signal type Button: There are four kinds of signal saved in the test signal board, namely color vertical bar, white-black vertical bar, chessboard-grid and white-black vertical line.
2.1.7 Other Functions If the panel locked, the device will have a bell warning when press the MENU button, or if the panel unlocked, the LED will display the MENU menu as the following figure 14 when press the MENU button. ① Check device information about input signal and output load. ② Check device information about temperature and voltage. ③ Set cable length of input channel. ④ Copy output channel EDID to input channel.
Section 3: System Management 3.1 Description SW-DVI-16X16 can be managed by two different ways: RS232 or through Network (IP) 3.1.1 1. 2. Control by RS232 Male 9-Pin D Connector: Pin 2: RXD Pin 3: TXD (Send) (Receive) Pin 5: GND Other Pins: N/A (Ground) Baud Rate: 9600 bit/s, 8 bit, one stop bit, no parity bit 3. Protocol Format: SW-DVI-16X16 supports both the LIGUO hex protocol format (the A communication format) and the B communication format. 4.
b. c. d. e. According to the DOS direction, input the command: telnet 192.168.0.104 9999 (192.168.0.104 9999 is the current device’s IP address) then the information shows as follows. The serial code of produce: XXXXXXX MAC address: XX:XX:XX:XX:XX:XX Vision number of Software: XX.X (XXXXXX) Press “Enter” to come into the mode of setting parameter.
b. c. d. According to DOS direction, Input the command: arp -s 192.168.0.123 XX-XX-XX-XX-XX-XX (192.168.0.123 is temporary address; XX-XX-XX-XX-XX-XX is the MAC address of equipment) and press, “enter”. Input “telnet 192.168.0.123 1” Input “telnet 192.168.0.123 9999”. After that set up and save a new IP address based on your existing IP schema Since the IP address assigned is temporary, if unit is restarted without saving the IP address, it will be lost. To save IP address input command “telnet 192.168.
5. 6. 7. 8. 9. Output data 1~N It symbolized codes of output ports; the range is from 0x00 to the maximum number that the device supports. Input data 1~N It symbolized codes of input ports; the range is from 0x00 to the maximum input number that the device supports. 00x0 means input No.1; 0x01 means input No.2. Please caution that the maximum input port number’s code plus ONE symbolized closing this port. For example, the device supports eight input ports, then 0x07 symbolizes No.
For example:Get the information of equipment’s type Commands: 0xeb, 0x90, 0x00, 0x01, 0x49 Response: 0xeb, 0x90, 0x00, 0x03, 0x80, 0x10, 0x10, Redundancy 2. Command 0x01 Function Tie the input channel to output channel 0xeb, 0x90, 0x01, N, Input Number of output channel Format 1…Input Number of output channel N. Response 0xeb, 0x90, 0x01, 0x01, 0xfa, Redundancy Note: The range of N is from 0x01 to 0x11. Note: The range of Input Number is from 0x00 to 0x11.
Note: Mark 1 expresses in binary as this mode “ 0,0,0,0,bit3,bit2,bit1,bit0 ”,bit0 to bit3 means the marks of signals at input channel 1 to 4 respectively,if the bit value is 1,then the corresponding input channel has signal, or if the bit value is 0, the corresponding input channel has not signal. So to the Mark 2,its value expresses the signals of the input channel 5 to 8. So to the Mark 3,its value expresses the signals of the input channel 9 to 12.
0xeb, 0x90, 0x04, N, Output Number 1 , … , Output Number N,Redundancy Note: The range of Input Number is as same as the note 2 of command 0x01 Note: The range of Output Number is as same as the note 2 of command 0x02 For example:Get the tied status of an appointed input channel Commands: 0xeb, 0x90, 0x04, 0x02, 0x01, 0x04 Response: 0xeb, 0x90, 0x04, 0x02, 0x01, 0x05, Redundancy Explanation: The input channel 5 has been tied to output channels 2 and 6.
Note: The range of Output Number is as same as the Note 2 of command 0x02 For example: Tie an appointed output channel to the Preset Input Channel Commands: 0xeb, 0x90, 0x06, 0x01, 0x04 Response: 0xeb, 0x90, 0x06, 0x01, 0xfa, Redundancy Explanation: The output channel 5 has been tied to the Preset Input Channel. 8.
channel 1,……,the EDID mark of the input channel 16, Redundancy Note: 0x10 is the num of input channels. If the EDID mark of the input channel 1 is 0x01, it means the EDID of the output channel 2 is copied to the input channel 1, and so to the mark of other input channels. If the mark is 0x11, it means the default EDID is copied to the input.
Response: 0xeb, 0x90, 0xfa, 0x11, 0x00, 0x00, 0x00, 0x00, 0x01, 0x01, 0x01, 0x01, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, Redundancy Explanation: The output channels 5 to 8 have loads; other output channels have no loads.
equipment has not been initialized; If the mark value is 0x01, then the equipment has been initialized, but the module is still without power: If the mark value is 0x02, then the equipment already power on and work well. Note: The Baud Value of serial port is fixed 0x00, it stands for 9600bit/s,8bit,1 stop bit, no parity. Note: The type of equipment value is 0x80, and it stands for DVI type.
2. ASCII Character Table ASCII Val ASCII Val ASCII Val ASCII Val ASCII Val Char. Esc DEC 27 HEX 1B Char. 1 DEC 49 HEX 31 Char. E DEC 69 HEX 45 Char. Y DEC 89 HEX 59 Char.
Commands sent by PC: 1*3& Response by the device: Out03·In01·DVI↵ Tie multiple input channels to multiple output channels Function Format Response Tie multiply input channels to multiply output channels [ESC] Q [X3]*[X2]! … [X3]*[X2]! ← Out·Multi·In·Multi·All↵ For example: Tie the output channels 4,5,7 to the input channels 3,3,6 respectively Commands sent by PC: [ESC]Q3*4&3*5&6*7&← Response by the device: Out·Multi·In·Multi·All↵ Tie all output channels to the appointed input Function Format Response Ti
Function Format Response View the status of single output channel V[X2]& or v[X2]& Out[X2]·In[X3]·DVI↵ For example: View the switch status of the output channel 7 Commands sent by PC: V7& Response by the device: Out07·In02·DVI↵ Explanation: The output channel 7 is tied to the input channel 2. Get the Software Version Function Get the software version. Format Q or q Response Ver[X].[X]↵ Note:”*X+.*X+” stands for software version。 For example :Get the software version.
Function Get the load mark of output channels Format [X4]*04S Response Xf·Xf·…·Xf·Xf·Load↵ If Xf is 0, it means no load. If Xf is 1, it means there is load For example : Get the load mark of output channels Commands sent by PC: 1*4S Response by the device: 00·01·01·01·00·00·00·00·Load↵ Explanation: The output channels 2,3 and 4 have loads.
Section 4: Maintenance 4.1 Replace the Fuse There is a spare fuse hidden in the power socket. Pull out the power cord and open the place showed on the picture, then pull out the fuse socket and put in a new fuse. For safety consideration, please cut off the power supply before replacing the new fusee. 4.
Section 5: Specifications Description Input Connector Output Connector Network Connector RS232 Connector Input Resolution Supported Input Signal Supported Output Signal DVI-D x 16 DVI-D x16 RJ45 DB9 Male 1600x1200x60Hz DVI 1.0 Same as Input Standard 24MHz – 165MHz RS232 or TCP/IP – 10M AC 180V ~ 250V 50Hz 100mA < 40W Pixel Clock Frequency Control Options Power Supply Max Output Current of Each Channel Power Consumption Dimension (mm) 483x133x305 (3U Rack) 6Kg Weight www.avenview.
Disclaimer While every precaution has been taken in the preparation of this document, Avenview Inc.