User`s guide

www.avenview.com
15
5. Output data 1~N
It symbolized codes of output ports; the range is from 0x00 to the maximum number that the device
supports.
6. Input data 1~N
It symbolized codes of input ports; the range is from 0x00 to the maximum input number that the
device supports. 00x0 means input No.1; 0x01 means input No.2. Please caution that the maximum
           
eight input ports, then 0x07 symbolizes No.8 port, 0x08 symbolizes close.
7. Pre-select input through long-distance control
Similar with input by keyboard
8. Address
0x90
9. Response
a. The equipment correctly receives and executes the command. Then execute the command and
response as follows. 0xebAddressCommand0x010xfaRedundancy.
b. The equipment receives the address correctly but data out of the ra
the command and response as follows. 0xeb Address Command 0x01 0xf2
Redundancy.
c. 
command and response as follows. 0xebAddressCommand0x010xf3Redundancy.
d.            
the command and response as follows. 0xeb Address Command 0x01 0xf7
Redundancy.
e. The equipment receives the address correctly but the command i    
execute the command and response as follows. 0xebAddressCommand0x010xf1
Redundancy.
f. The equipment receives the address wrongly. No response.
3.1.6 Commands
1. Command 0x00(two functions)
Function 1
Get the equipment address and software version
Format
0xeb, 0x00, 0x00, 0x01, 0x01
Response
0xeb, Address, 0x00, 0x02, Version, 0xfa, Redundancy
For exampleGet the equipment address and software version
Commands: 0xeb, 0x00, 0x00, 0x01, 0x01
Response: 0xeb, 0x90, 0x00, 0x02, 0x10, 0xfa, Redundancy
Function 2

Format
0xeb, 0x90, 0x00, 0x01, 0x49
Response
0xeb, 0x90, 0x00, 0x03, Input Signal TypeMaximal Input
Channel QuantityMaximal Output Channel Quantity
Note: The value of Input Signal Type is 0x80,it means DVI type