User guide
15 
4.  I/O Control Instruction 
I/O terminal connector – used in application, for e.g., motion detection, event triggering, alarm 
notifications. It provides the interface to: 
  Digital Input (GND+Alarm) : An alarm input for connecting devices that can toggle between an 
open and closed circuit, for   
1. GND (Ground) : Initial state is LOW 
2. Alarm : Max. 50mA, DC 3.3V 
Example: PIRs, door/window contacts, glass break detectors, etc. When a signal is 
received the state changes and the input becomes active. 
  Relay output (COM +N.O.) / (COM+N.C.) : An output to Relay switch, for example: LEDs, 
Sirens, etc 
1. N.C. (Normally Close): Max. 1A, DC24V or 0.5A, AC125V 
2. COM: (Common) 
3. N.O. (Normally Open): Max. 1A, DC24V or 0.5A, AC125V 
[Example] 
RELAY INSTALLATION EXAMPLE 1 
Trigger a “Normal OFF” (Normal Open) alarm siren on when event/motion occur: 
ALARM IN 
RELAY OUT 