Product data

6.7 Tares 55
XM and XT Operator Instructions
6
Tare interlock (label mode only)
In label mode, if the tare interlock has been enabled, you can only print
a label if you have selected a tare. It operates in one of two ways:
Enabled
Note: This only applies
to manually selected
tares. If a PLU with a
stored tare is displayed
and another PLU with a
stored tare is selected,
the interlock does not
operate.
The manually selected tare can be overridden by a PLU with a stored
tare. The stored tare overrides the manually selected tare.
Enab. & Fix Tare
A manually selected tare cannot be overridden by a stored tare. You
will see a message and the new tare will be cancelled.
6.7.5 Pre-pack tares
In pre-pack mode, the PLU and tare are not cancelled when the filled
container is removed from the weigh plate. This enables you to pack
several containers of the same weight and use the same PLU without
having to select the PLU and set up the tare each time.
There are three types of tare available when pre-packing:
O Stored tare
O Free tare
O Keyboard entered tare
Tare values (container weights) are stored against a reference number
that can be programmed in the PLU.
Free and keyboard entered tares are described in 6.7, Tares, page 52.