Shizuku USB Multimeter PC Software UI Manual V1.00.44 0.1 Version & Update Due to the complexity of the features, software/firmware/hardware can vary frequently, this manual might not be applicable for the latest software/firmware/hardware release. 0.2 Revision History V1.00.44 20200815 1. Added manual for the load module. 1.0 Connect the meter Connect the meter and PC with a micro USB cable.
Double-click the device, the following should be shown: Now we will introduce the features one by one: 2.
2.0.0 Create New Click "Create New" to create a new record. 2.0.1 Sample Rate Drag to adjust the sample rate of the record, range 0.2-1000sps. 2.0.2 Auto Start/Stop Behavior After clicking the start button, the record will not start immediately. The program waits for the current to go above Start Current , then it starts record. If you want the record to start immediately, you should set Start Current to 0.
You can specify a current, below which the record stops automatically. If this value is specified as 0, the record will never stop automatically. To prevent instantaneous low current triggered stop condition unexpectedly, you can set "Stop Delay" parameter, only the current is below the stop threshold for a certain amount of time(Stop Delay t), the record will be stopped. 2.0.3 Record Items To change the color of a record item, click the color combo box.
Click and hold some point on the graph, to view detailed value at that point. Right click and drag to move the graph horizontally. Use the wheel to zoom in/out. 2.
2.1.1 Sample Rate Drag to adjust the sample rate, range 0.1-3.2Msps. 2.1.2 Sample Depth Drag to adjust the sample depth (How many points are contained per sample). 2.1.3 Trigger Edge Click to select the trigger edge. 2.1.4 Trigger Mode Click to select the trigger mode. 2.1.
Drag to specify the edge voltage. 2.1.6 Graph Area Graph area is on the right side of the screen. Click and hold a point on the graph to see precise value on that point. Right click and drag to move the graph horizontally. Use the wheel to zoom in/out. 2.2 Lua Script This article only describes lua related features on the software, for more information, please visit: TODO TODO TODO 2.2.1 Memory Status Real-time memory status is shown here. 2.2.
2.3.1 Select the protocol Select the protocol being triggered here. 2.3.2 Protocol Properties Here properties of the protocol you've selected are shown. 2.3.
2.4 PD Listener To use listener, please follow the following procedure strictly: 1. Make sure PD communication switch is on the "ON" position. 2. Connect the charger and the meter with a C-C cable. 3. Click green start button. 4. Use another C-C cable to connect the other Type-C port to your being tested device. 5. If you expected some message to appear but it didn't, you might need to flip one of the Type-C plug connected on the meter. 2.4.
2.4.2 File Operations You can save and open PD listener stream: 2.
The module panel contains the expansion modules accessible from the software. 2.5.1 Load Controller You can operate load modules mounted on the meter here.
Capabilities and the status of the module is shown above. To start the load, you select the load mode here first. Usages for different modes are stated below: CC Mode : Constant current mode, usually used for aging or capacity tests. CP Mode : Constant power mode, usually used for aging or capacity tests.
Ramp-Up Mode : In this mode, the load is increased gradually, from Start Current , to Stop Current , with specified slope Slope . This is usually used to determine the maximum load capability of a power source. Apply this combined with graphing yields a V-I graph of the power source. Then, you set the parameters for your mode (Different modes have different parameters). You can either drag the scrollbar or edit the value in the textbox directly. Finally, you click the start button. 2.6 System 2.6.
Click refresh button to capture new screenshot, click save button to save the screen shit. Notice that some UI might not be able to be captured (Mostly graphing like VBUS oscilloscope, VBUS & IBUS graph), as they utilizes different graphic mode.