User's Manual

862-01545 ยตLink System Manual
Issue 1 Page 29
Indoor Unit
Installation
Follow these steps to install the IU. See Figure 8.
Step Action
5. Install the Data Interface module into the IU
by sliding it in until the male connector on the
module mates firmly with the female connector
inside the IU.
6. Secure the Data Interface module to the IU
with the two (2) x M4 screws provided.
7. Slide the IU into the 19" rack and secure to the
rack using four (4) x M3 screws. Note that if
the unit is to be table mounted, first fit the four
(4) x rubber feet to each corner on the base of
the IU.
8. Earth the IU by connecting the earth cable or
strap between the station earth and the earth
stud on the IU rear panel.
9. Observing the polarity of the supply, wire up
the supplied power connector cable plug and
connect it to the facility DC supply (21 to
56 V) through a minimum 10 A circuit
breaker. Secure the connector screws to the
unit. Check the supply voltage using the
Multimeter.
OR
Connect the AC power cable from the station
power source to the AC power connector on
the rear panel of the IU.