User Manual

MDR5800 User Manual
862-01881 Issue 6
Object ID Group Object Type Access Description
probably in terms of the equipment
connected to it.
1.3.6.1.4.1.1316.1.1.1.5.1.2 mdrmteRelay1OpenStateLabel DisplayString read-write A short, descriptive name indicating
the primary function of the relay in the
open state, most probably in terms of
the equipment connected to it.
1.3.6.1.4.1.1316.1.1.1.5.1.3 mdrmteRelay1ClosedStateLabel DisplayString read-write A short, descriptive name indicating
the primary function of the relay in the
closed state, most probably in terms
of the equipment connected to it.
1.3.6.1.4.1.1316.1.1.1.5.1.4 mdrmteRelay1Reserved INTEGER
1.3.6.1.4.1.1316.1.1.1.5.1.5 mdrmteRelay1CurrentState INTEGER read-write The current state of the relay. Used to
activate/deactivate a relay.
1.3.6.1.4.1.1316.1.1.1.5.1.6 mdrmteRelay1ScriptTable SEQUENCE
1.3.6.1.4.1.1316.1.1.1.5.1.6.1 mdrmteRelay1ScriptEntry SYNTAX
1.3.6.1.4.1.1316.1.1.1.5.1.6.1.1
mdrmteRelay1ScriptIndex
6
INTEGER
1.3.6.1.4.1.1316.1.1.1.5.1.6.1.2 mdrmteRelay1ScriptID INTEGER read-write Defines which of the listed alarms can
cause a relay to activate.
1.3.6.1.4.1.1316.1.1.1.5.1.6.1.3 mdrmteRelay1ScriptActiveLocal INTEGER read-write Defines if the script is active or not for
local relay activation.
1.3.6.1.4.1.1316.1.1.1.5.1.6.1.4 mdrmteRelay1ScriptActiveRemote INTEGER read-write Defines if the script is active or not for
remote relay activation.
1.3.6.1.4.1.1316.1.1.1.5.2 mdrmteRelay2
1.3.6.1.4.1.1316.1.1.1.5.2.1 mdrmteRelay2Label DisplayString read-write A short, descriptive name indicating
the primary function of the relay, most
probably in terms of the equipment
connected to it.
1.3.6.1.4.1.1316.1.1.1.5.2.2 mdrmteRelay2OpenStateLabel DisplayString read-write A short, descriptive name indicating
the primary function of the relay in the
open state, most probably in terms of
the equipment connected to it.
1.3.6.1.4.1.1316.1.1.1.5.2.3 mdrmteRelay2ClosedStateLabel DisplayString read-write A short, descriptive name indicating
the primary function of the relay in the
closed state, most probably in terms
of the equipment connected to it.
1.3.6.1.4.1.1316.1.1.1.5.2.4 mdrmteRelay2Reserved INTEGER
1.3.6.1.4.1.1316.1.1.1.5.2.5 mdrmteRelay2CurrentState INTEGER read-write The current state of the relay. Used to
activate/deactivate a relay.
1.3.6.1.4.1.1316.1.1.1.5.2.6 mdrmteRelay2ScriptTable SEQUENCE
1.3.6.1.4.1.1316.1.1.1.5.2.6.1 mdrmteRelay2ScriptEntry SYNTAX
1.3.6.1.4.1.1316.1.1.1.5.2.6.1.1 mdrmteRelay2ScriptIndex INTEGER
1.3.6.1.4.1.1316.1.1.1.5.2.6.1.2 mdrmteRelay2ScriptID INTEGER read-write Defines which of the listed alarms can
cause a relay to activate.
1.3.6.1.4.1.1316.1.1.1.5.2.6.1.3 mdrmteRelay2ScriptActiveLocal INTEGER read-write Defines if the script is active or not for
6
Relay scripting is not activated in Versions 1.0 & 2.0 of the IU firmware release.