User Manual

MDR5800 User Manual
862-01881 Issue 6 Page 25
4 INSTALLATION
This chapter describes a recommended installation procedure for the MDR5800.
Recommended installation procedure:
1. Install the Indoor Unit.
2. Prepare and connect the cables to the Indoor Unit.
3. Install the Outdoor Unit and antenna.
4. Install the Indoor-to-Outdoor Unit interconnection cables (the power and data
cables).
5. Turn the Indoor Unit power on.
6. Perform the initial software setup using the supplied NMS application
7. Repeat item 1-5 for the remote site.
8. Align the antennas (use the RSSI voltage on the OU or the RSSI value from
the MIB or the NMS Graphic User Interface to assist with the setup).
9. Perform a functional test and commission the link.
10. Connect to user data.
11. Start the system.
Installation of the MDR5800 elements is described in the following sections:
Installing the Indoor Unit.
Installing the Outdoor Unit and Antenna.
Installing the interconnection cables.