4.2.5 Connecting Auxiliary In/Out (Optional)
The auxiliary in/out port is used to:
Monitor switch-closure events using two isolated inputs.
Control line connections using normally-open and normally-closed relay
outputs.
Connect the port:
1. Assemble an auxiliary in/out cable using a High density 15 way D-type male
connector according to connector pin assignments shown in Table 4.
2. Connect to the cable Indoor Unit auxiliary in/out connector.
3. Secure the connector using locking screws.
Table 4. Auxiliary In/Out Connector Pin Outs
Indoor unit connector Pin
No
Signal
1 OUTPUT 1 COMMON
2 OUTPUT 1 NORMALLY-OPEN
3 OUTPUT 1 NORMALLY-OPEN
4 OUTPUT 1 NORMALLY-CLOSED
5 OUTPUT 1 NORMALLY-CLOSED
6 OUTPUT 1 COMMON
7 OUTPUT 2 COMMON
8 OUTPUT 2 COMMON
9 OUTPUT 2 NORMALLY-OPEN
10 OUTPUT 2 NORMALLY-OPEN
11 OUTPUT 2 NORMALLY-CLOSED
12 INPUT 1
13 INPUT 1 RETURN
14 INPUT 2
15-pin High density D-type female
15
11
15
6
10
15 INPUT 2 RETURN