User Manual

MDR5800 User Manual
862-01881 Issue 6 Page 47
6.4 NMS Menus
6.4.1 Main Screen Menus
The following pull-down menus are available from the Main menu:
Menu Sub-item Result
File Exit Exit from NMS.
Communications Allows setup of which communications port is
used on the PC or Laptop for communication
with the Indoor Unit via the front panel Element
Manager Serial Port.
Local Trib Code
It is possible to purchase upgrades for E1/T1
Indoor Units (upgrades to 2E1/T1 or 4E1/T1).
The user contacts the factory and provides the
Indoor Unit Bar Code number details. The
factory then supplies a “Tributary Code”, unique
to the Indoor Unit, which is entered using the
MIB (Version 1 & 2 products) or using the NMS
(Version 2 product).
Remote Trib Code See above.
Local User
Configuration
Allows the user to set the access control
settings for the local station equipment to allow
the user to log on as an ‘Administrator’ with full
read/write configuration access or with ‘Read-
only’ access. (Note: This option is only
available if the IU firmware has been supplied
with secure-features activated – the default is
NOT to have this feature activated).
Options
Remote User
Configuration
Allows the user to set the access control
settings for the remote station equipment to
allow the user to log on as an ‘Administrator’
with full read/write configuration access or with
‘Read-only’ access. (Note: This option is only
available if the IU firmware has been supplied
with secure-features activated – the default is
NOT to have this feature activated).
Spectrum
Analyzer
Allows the user to examine the RF spectrum
using a RSSI (received signal strength
indicator) value measured in the Outdoor Unit.
If interference exists, this feature allows the
user to examine the spectrum and decide
where to set the transmit and receive
frequencies for the local and remote stations.