User's Manual

Table Of Contents
ECLIPSE INSTALLATION MANUAL
NCC (Node Controller Card) provides Node management and DC-DC converter func-
tions. NCC is a mandatory card.
l It manages Node operation and event collection and management.
l It incorporates a router function for local and remote network management
interconnection.
l Node configuration and licensing data is held in flash-memory.
l Power supply: -48 Vdc (SELV -40.5 to -60 Vdc).
FAN (Fan card) provides forced-air cooling. FAN is a mandatory card.
NPC (Node Protection Card) provides 1+1 protection functions for the NCC power
supply and backplane management.
PCC (Power Conversion Card) supports operation from a +24 Vdc power supply.
Plug-in Cards Overview
For detail ed information on the pl ug-ins refer to the
Ecli pse Pl atfor m Product Descripti on.
RAC 60E
RAC 60E supports DPP (Data Packet Plane) operation, ACM (Adaptive Coding and
Modulation), and airlink recovered timing (ART) for high accuracy radio transport of
a SyncE clock.
There are four dynamically switched modulation rates; QPSK, 16 QAM, 64 QAM,
256 QAM. Coding options additionally apply on each of these modulations, one for
maximum throughput, one for maximum gain, to provide an effective total of eight
modulation states.
l Maximum throughput delivers maximum data throughput - at the expense of
some system gain.
l Maximum gain delivers best system gain - at the expense of some throughput.
l Up to four of the eight modulation states offered with ACM can be selected for
use.
l Modulation switching (state change) is errorless for priority traffic.
A DPP port enables direct routing of Ethernet traffic to a DAC GE3.
Individual ACM modulations can be set as fixed rates.
Channel bandwidths for ISM band operation range from 5 to 40 MHz.
ART operation is designed to meet G.8262 synchronization mask requirements for
SyncE clock transport.
Figure 1-4. RAC 60E
260-668066-004 AUGUST 2013 19