User's Manual

Table Of Contents
VOLUME II, CHAPTER 1, SYSTEM OVERVIEW
EZF-03: Secure Management (NMS)
Secure Management applies to Eclipse NMS access over the network, and to local
access via the Portal craft tool.
l Provides secure management access to Eclipse over an unsecured network.
l Protects Eclipse configurations from accidental or intentional modification by
unauthorized personnel.
l Keeps track of all events for accountability.
l Based on FIPS 140-2 validated algorithms.
EZF-04: Payload Encryption (RAC 60E)
Payload Encryption encrypts payload and management data on the wireless link to
prevent eavesdropping.
l Checks integrity of each data frame in the wireless link to ensure that received
data has been sent by the intended transmitter.
l Provides the same level of security as Wi-Fi and WiMAX.
l FIPS-197 compliant.
l Can be enabled/disabled independently for each wireless link.
l Meets US federal and commercial requirements.
EZF-05: Ethernet over TDM (DS3, DS1)
Enables mapping of Ethernet data to DS3, DS1 PDH interfaces using the DAC
3xDS3M or DAC 16xV2. Applies where a customer wishes to transport Ethernet data
over existing DS3 or NxDS1 radio or leased-line circuits.
l Ethernet data from the Eclipse backplane is mapped into a DS3 frame as DS1
(1.544 Mbps) multiples to a maximum 28xDS1, to support a maximum data
rate (available bandwidth for Ethernet) of 43 (43.232) Mbps per DS3. The DS3
connection must support unframed/transparent DS3.
l Ethernet data is mapped into NxDS1 frames at 1.544 Mbps per DS1 to a
maximum 16xDS1 on the DAC 16xV2, to support a maximum data rate
(available bandwidth for Ethernet) of 24 (24.7) Mbps.
EZF-06: RADIUS Client
Enables connection validation to a RADIUS server for centralized account man-
agement.
EZF-09: Synchronous Ethernet
Enables Synchronous Ethernet operation on DAC GE3 cards.
EZF-10: Ethernet OAM/ERP
Enables access to DAC GE3 Ethernet OAM and ERP capabilities.
EZF-51 to EZF-56: ODU 600 High Tx Power.
Unlocks an additional 3dB of transmit power over standard power. Applies, on all
modulations. It also increases the manual and ATPC transmit power control range
by 3dB.
34 AVIAT NETWORKS