User's Manual
Table Of Contents
- Eclipse ODU 600 5.8 GHz ISM Band Installation Manual Rev.001
- Copyright & Terms of Use
- Aviat Networks Support
- Eclipse Product Compliance Notes
- Contents
- Volume I: Introduction and Safety
- Volume II: System Overview
- Volume III: Installation
- Chapter 1. Introduction to Installation
- Chapter 2. ODU Installation
- Chapter 3. INU and INUe Installation
- INU/INUe Overview
- Installation Requirements
- Installation Procedure
- Plug-in Installation
- INU/INUe Cable Assemblies
- DAC Trib Connectors and Cables
- NMS Connectors and Cables
- NMS 10/100Base-T Connector
- Maintenance V.24 Connector
- Auxiliary and Alarm Connectors and Cables
- AUX Data Cable: Async, HD26 to Wirewrap, 2 m
- AUX Data Cable: Sync, HD26 to Wirewrap, 2 m
- AUX Data Cable: Async, HD26 to 3 X DB9, 1 m
- AUX Data Cable: Sync, HD26 to 3 X DB9, 1 m
- AUX Data Cable: Async, AUX HD26 to AUX HD26, 1 m
- AUX Data Cable: Sync, AUX HD26 to AUX HD26, 1 m
- AUX Alarm I/O Cable: HD15 to Wirewrap, 2 m or 5 m
ECLIPSE INSTALLATION MANUAL
Weatherproofing
Weatherproofing kits are included with the ODU cable and lightning surge arrestors.
Two types of weatherproofing media are supplied. Refer to:
l Mastic Tape on page 69
l Self Amalgamating Tape on page 70
Mastic Tape
The ODU cable ground kits include rolls of vinyl and butyl mastic tape. A two-layer
wrap process is recommended:
l An initial layer of mastic. It is this tape that provides the weatherproofing.
l A top layer or layers of vinyl tape to support good amalgamation and
adhesion of the mastic tape and to provide UV protection.
Where mastic tape is used to weatherproof connector s a
three-layer process is recommended, where a center layer of
vinyl tape is applied before the mastic to facilitate easy strip-
back when connector disconnecti on is required. Special atten-
tion must be given to ensuring the masti c tape seals cleanly
to the primary surfaces, such as the cable jacket.
Wrapping Guidelines, Mastic (Butyl) Tape
To weatherproof connectors start at 1. To weatherproof a cable ground start at 3.
1. Ensure connectors are firmly hand-tightened, dry, and free from all grease and
dirt. If necessary, clean with rag lightly moistened with alcohol-based cleaner.
2. Using vinyl tape, pre-wrap just the center section of the connector barrel - the sec-
tion to which access will be needed if the connector ever needs to be undone. Use a
25% overlay when wrapping. To avoid curl-back do not stretch the tape too tightly at
the end point.
On an ODU connector, leave at least two-thirds of the smooth
length of the barrel clear of pre-wrap vinyl tape, to ensure
the masti c tape has sufficient area of di rect grip.
3. Wrap with mastic tape using a half to 2/3rds width overly, and ensure there is at
least a 25 mm (1”) attachment onto the primary surfaces to either side (cable jacket,
ground wire, connector).
For a cable ground, ensure there is no possibility of water penetrating between the
ODU cable and its ground wire by first applying and forming mastic tape around the
260-668066-004 AUGUST 2013 69