VOLUME III, CHAPTER 3, INU AND INUE INSTALLATION
INU/INUe Cable Assemblies
CAUTION:Eclipse tributary, auxiliary and NMS cables are not to be
routed with any AC mains power lines. They are also to be kept away
from any power lines which cross them.
For safety reasons tributary, auxiliary and NMS cables should not be
connected to outside plant.
Use approved surge suppression equipment when connecting to un-
protected external inputs and outputs.
Refer to:
l DAC Trib Connectors and Cables on page 86
l NMS Connectors and Cables on page 97
l Auxiliary and Alarm Connectors and Cables on page 99
DAC Trib Connectors and Cables
This section provides cable and connection data for:
l DAC 16xV2 Cable and Connector Data on page 86
l DAC 4x Cable and Connector Data on page 92
l DAC GE3 Ethernet RJ-45 Cables on page 94
l DAC Optical Cable and Connector Data on page 95
l DAC 155eM Cables on page 97
DAC 16xV2 Cable and Connector Data
Refer to:
l DAC 16xV2 HDR-E50 To 24 AWG Free End Cable Assembly on page 86
l DAC 16xV2 HDR-E50 To BNC Cable Assembly on page 87
l DAC 16xV2 HDR-E50 To RJ-45 Cable Assembly on page 88
l DAC 16xV2 HDR-E50 To Free End Y-Cable Assembly on page 89
l DAC 16xV2 HDR-E50 To BNC Y-Cable Assembly on page 90
DAC 16xV2 HDR-E50 To 24 AWG Free End Cable Assembly
The assemblies provide balanced 120 ohm connections on cable lengths of 3m, 10m,
15m or 32m. The wire is intended for use with wire-wrap or insulation displacement
termination blocks.
86 AVIAT NETWORKS