3.0

Table Of Contents
Configuring the Thunder
173
3. In the Protocol Setup dialog box, do the following:
- Select a channel (1-8) in the Channel area.
- Set Protocol to ThunderNET.
- If you intend to use a different database for the channel, enter it in the Database
(Blank = default DB) field.
4. Leave the rest of the settings as is.
5. Repeat step 3 for all physical channels, plus an extra channel that is used by Command
to send inventory and transport commands. Normally, there are two hardware channels
and one software channel.
6. Click OK.
7. Select File > Preferences > Channel Configuration.
The Channel Configuration dialog box opens.
8. Set the Hdw Channel to correspond to the channels you set protocols for in step 3. The
physical channels should be set to Hdwr; the extra channel should be set to Soft.
9. Uncheck the channels in the MiniMon column that you will not be using.
10. Click OK.
11. In the Thunder directory, right-click on the database that you intend to use and set it as
the default database.