Specifications
Appendix A: Card Removal and Replacement 19
appendix a
Card Removal and Replacement
Removing an I/O Card
In the event of a problem with either of the dig-
ital I/O cards in your 192 Digital I/O, you can re-
move the card and send it to Digidesign for re-
pair. 
The modular nature of the HD system allows 
you to simply return the specific card, instead of 
the entire 192 Digital I/O. Your HD system will 
continue to function while missing a single 
card. It will not function if more than one of the 
factory-installed cards is removed.
To remove an I/O card from the 192 Digital I/O:
1 Power off and disconnect the 192 Digital I/O 
from your HD system.
2 Make sure that the equipment is properly 
grounded.
3 Remove the top cover of the 192 Digital I/O 
by extracting the 16 small Phillips-head screws 
around the edges of the top cover, and lift it off. 
Put the screws in a safe place.
4 Remove the five screws on the front plate of 
the card to be removed.
5 Gently pull the 50-pin connector off of the 
edge of the card.
6 Pull the card out by gripping the edges be-
tween your thumb and forefinger on each side. 
Pull straight back, lifting very slightly to avoid 
contact between components on the underside 
of the card and the 192 Digital I/O back panel 
faceplate.
7 Place the card immediately in an anti-static 
bag and send it to Digidesign according to in-
structions from the Customer Support dept.
Before handling any of the cards or internal 
components of 192 Digital I/O, discharge 
any static electricity by touching the outer 
casing of the power supply.
When you pull a card out, pay particular at-
tention to keeping components on the sur-
faces of the card from bumping into any of 
the internal components or the back panel 
faceplate on the 192 Digital I/O.
Pulling the card out
When you pull a card out, pay particular at-
tention to keeping components on the sur-
faces of the card from bumping into any of 
the internal components or the back panel 
faceplate on the 192 Digital I/O.