User Manual-MADI

HD OMNI Guide26
Curv Attenuates the incoming analog signal us-
ing a soft knee limiter circuit. This guarantees
super soft limiting without becoming hard, even
with large overloads on input.
Analog Out
The Analog Out page of the Hardware Setup di-
alog lets you set the Output Level for the physi-
cal analog outputs on HD OMNI. You can also
select which channels are mirrored on the back
panel TRS Outputs.
Output Level
Select the appropriate Output Level for each of
the eight analog output channels. HD OMNI
provides two options for output levels:
Speaker (+10 dBu) Select this option for output
channels connected directly to powered moni-
tors.
Line (+24 dBu) Select this option for output
channels connected to line-level devices (such
as an analog mixing console).
TRS Mirrors
The TRS OUT 1 and 2 jacks on the back panel of
HD OMNI can mirror the analog signal output
of channels 1–2 or 7–8. Select the appropriate
option depending on your monitoring configu-
ration:
Analog 1–2 Select this option if you want to
monitor analog output channels 1–2 though
TRS OUT 1 and 2.
Analog 7–8 Select this option if you want to
monitor analog output channels 7–8 through
TRS OUT 1 and 2.
None Select this option if you do not intend to
use TRS OUT 1 and 2 for monitoring.
Monitor
The Monitor page of the Hardware Setup dialog
is a virtual patchbay where you can define
which physical outputs are used for the MAIN
and ALT monitoring paths. You can assign ded-
icated monitoring paths to any of the available
Analog 1–8, AES/EBU 1–8, or stereo digital out-
puts.
Hardware Setup, Analog Out page
Hardware Setup, Monitor page