User Manual-MADI

HD OMNI Guide48
To enter SPL Display Calibration mode:
1 Enter SETUP mode. The SETUP LED lights
green.
2 Turn the MONITOR encoder until the display
shows “SPLCAL.”
3 Press the MONITOR encoder button to select
SPLCAL. The SETUP LED blinks on and off.
4 Turn MONITOR encoder until the display
shows one of the following options:
CalMn (calibrate SPL for MAIN)
– or –
CalAlt (calibrate SPL for ALT)
5 Press the MONITOR encoder button to select
the displayed option.
6 For the selected Monitor Path option (MAIN
or ALT), turn the MONITOR encoder until the
display shows SET.
7 Press the MONITOR encoder button to select
the SET. The display changes to show 85SPL.
8 Turn the MONITOR encoder to until the SPL
reading is displayed.
9 Press the MONITOR encoder button to con-
firm the setting.
10 Press SETUP button to exit SPLCAL and re-
turn to top level of SETUP Options menu. The
SETUP LED stops blinking and lights solid green.
11 Exit SETUP mode.
To cancel the SPL value:
1 Enter SETUP mode. The SETUP LED lights
green.
2 Turn the MONITOR encoder until the display
shows “SPLCAL.”
3 Press the MONITOR encoder button to select
SPLCAL. The SETUP LED blinks on and off.
4 Turn MONITOR encoder until the display
shows one of the following options:
CalMn (calibrate SPL for MAIN)
– or –
CalAlt (calibrate SPL for ALT)
5 Press the MONITOR encoder button to select
the displayed option.
6 For the selected Monitor Path option (MAIN
or ALT), turn the MONITOR encoder until the
display shows NO SPL.
7 Press the MONITOR encoder button to con-
firm the setting.
8 Press SETUP button to exit SPLCAL and return
to top level of SETUP Options menu. The SETUP
LED stops blinking and lights solid green.
9 Exit SETUP mode.