User Manual

Preserving HD Closed Captioning and Ancillary Data
1102
n
The slot 3 default has changed from DTV to AFD, which is different from previous releases.
To set options for ancillary data preservation for a single slot:
1. Select Tools > Console.
2. Type the following command with the appropriate options:
Embeddnxccoptions <slot> <on/off> <optional DID & SDID>
The following table describes the options you can set in the command:
For example:
- To turn off data slot 1, type
Embeddnxccoptions 1 0
- To set data slot 2 to hold CEA 708 data, type
Embeddnxccoptions 2 1 0x61 0x01
- To set data slot 4 to hold a custom data type, type
Embeddnxccoptions 4 1 0xaa 0xbb
where
aa
and
bb
are the DID and SDID of the custom data type
To view the current status of each slot:
1. Select Tools > Console.
2. Type the following command:
Embeddnxccoptions
Data Packet DID SDID
CEA 708 61 01
CEA 608 61 02
AFD 41 05
AT C 6 0 60
Option Description
Slot A value from 1 to 4 that specifies a data slot
On/Off A value of 1 or 0
DID A hex number (for example, 0x61)
SDID A hex number (for example, 0x60)