The projector is equipped with a built-in protection circuit to prevent re and breakdown due to faults.
When the LAMP/COVER LED lights in red
Measurestobetaken
1. Disconnect the power plug from the outlet.
2.Properlyinstallthelampunitcover.See"ReplacementoftheLampUnit"onPageE-46.
When the TEMP LED flashes or lights steadily
Measurestobetaken
1. Disconnect the power plug from the outlet.
2. Check the following matters and perform the countermeasure properly.
Fault Protection
Is the ambient temperature
inexcessof35°C(95°F)?
Please use the projector in an operation ambient temperature
of0°C(32°F)to35°C(95°F).
Are the ventilation vents
blocked?
Rearrange the setup location of the projector and separate the
projector fromsurrounding objects. See"DoNotBlock the air
vents"onPageE-4.
Breakdown of an internal cir-
cuit could be the problem.
Please request repair at your dealer of purchase.
* The projector is running properly when the TEMP LED turn off.
* When the LAMP/COVER LED is lit red at the same time, please replace the lamp. See Page E-46 for information about
the replacement method.
* TheashingoftheTEMPLEDisawarningofahightemperature.
Whenthe usagecircumstanceshavenot changedafter 10secondshaveelapsedsince thestart ofthe ashing,the
TEMP LED changes to be lit steady and the lamp goes off.