Pr o 64 us e r In t e r f a c e
Slots and Sample Rate
The current system‑wide sample rate will determine the number of A‑Net Slots that are available.
Sample Rate A-Net Slots Yamaha Compatibility
44.1kHz 64 Yes
48kHz 64 Yes
88.2kHz 32 Yes
96kHz 32 Yes
176.4kHz 16 No
192kHz 16 No
Even though the network sample rate may change the available number of A‑Net Slots, the I/O capacity of a
hardware device does not change. That is, a 16channel input module in a 96kHz network can still have all of its
channels activated.
The current network sample rate will also affect the display of available A‑Net Slot ranges. Slot ranges will always
have the same maximum number as seen in the sample rate chart. At 96kHz, for example, only Slots 1 through 32
are available; the Slot range from 33 to 64 is inactive and unavailable at 96kHz.
Slot ranges outside the maximum for the current sample rate can be selected, but attempting to activate a
channel in an unavailable range will result in an error message on hardware I/O modules (the selected channel
button, A‑Net Slot range, and sample rate LEDs will all flash). Note that console interfaces such as the 6416Y2 card
have no A‑Net Slot displays and cannot display these error messages. When using Pro64 Network Manager, Slots
outside the limits of the current sample rate cannot be activated.
P No t e : Yamaha devices do not support sample rates above 96kHz.