Owner manual

Card 2 of 3
The second card in the 48 x 16 digital snake receives Slots 17‑32 from the network. It has the same Transmit Slot
settings as card #1, but note that all 16 activation switches in blocks SW1 and SW2 are in the off (down) position.
ON
ON
ON
ON
ON
ON
SW7
SW8
SW3
SW9
SW4
SW1
SW2
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
49-56 OFF
57-64 OFF
Receive 17-32
Transmit 49-64
MY16
The second 6416Y2 card in the 48 x 16 digital snake receives Slots 17-32 and transmits nothing into the network.
Since the Transmit Slot range in SW9 is set to Slots 49‑64 but has no active channels (as seen in SW1 and SW2) this
parameter could be set to any other range with no impact on the digital snake’s operation.
44
co n f I G u r I n G t h e 6416Y2 ca r d