Instruction Manual

13Fr o N t PA N e l Fe A t u r e s
In an all‑analog network, the sample rate can be set at the Control Master to
the following:
44.1kHz•
48• kHz
88.2• kHz
96• kHz
176.4• kHz
192• kHz
When an external clock is used with a Pro64 digital I/O device, the system
can lock to any sample rate within one of the three ranges shown in the table
below.
Pro64 Series Supported Sample Rates
Sample Rate Minimum Maximum
44.1/48kHz 39.7kHz 52kHz
88.2/96kHz 79.4kHz 104kHz
176.4/192kHz 158.8kHz 208kHz
Pro16 Outputs
The current Pro64 sample rate has a direct effect on the number of Pro16
channels that can be output from the A‑Net Systems Interface. The Pro16
outputs are in banks of sixteen channels.
Pro64 Sample Rate Pro16 Outputs Available
44.1kHz 116, 17‑32, 3348, 4964
48kHz 116, 17‑32, 3348, 4964
88.2kHz 116, 17‑32
96kHz 116, 17‑32
176.4kHz 116
192kHz 116
The Pro16 Output LEDs on the front panel of the ASI will display the available
Pro16 outputs, based on the current Pro64 network sample rate.
Pro64/Pro16 Channel Mapping
At 44.1/48kHz, all four Pro16 outputs on the ASI can be used. Each is mapped
in a one‑toone relationship to its Pro64 channel counterpart (Pro64 channel
1 is output as Pro16 channel 1; Pro64 channel 23 is output as Pro16 channel
23, etc.). No channel remapping is possible between the two data formats.