Instruction Manual

14Fr o N t PA N e l Fe A t u r e s
At 96kHz, only 32 channels are output to the rear‑panel Pro16 A‑Net outputs.
Channels 33‑64 will have no data available. Pro16 devices connected to the
33‑48 and 4964 ports on the ASI will not output any data.
When a Pro64 network is running at the 2x (88.2/96kHz) rate, Pro16 devices
should be connected to only the first two Pro16 output ports.
At 192kHz, only Pro64 channels 1‑16 are sent to the Pro16 outputs. Channels
1764 will have no Pro16 data available. Pro16 devices connected to the 17‑32,
33‑48, and 4964 ports will not output any data.
When a Pro64 network is running at the 4x (176.4/192kHz) sample rate, Pro16
devices should be connected to only the first Pro16 output port.
This diagram shows a Pro64 network operating at the 1x (44.1/48kHz)
sample rate. Its 64 audio channels are available as Pro16 data in four banks
of 16 at the rear-panel Pro16 outputs on the ASI. All four Pro16 Available
Output LEDs are lit.
A-Net LED
The blue LED found within the A‑Net logo functions as the network activity
indicator. When a module is powered up, its A‑Net LED will flash while a
request to enter the network is sent to and then processed by the Control
Master.