IP Power 9258xx User Manual Release Date: 11/09/2012 Manual Version: 1.0 Firmware: Ver. 4.
Warning: Any changes made to this equipment without permission may cause damages to the device! IMPORTANT NOTICE 1. IP Power 9258xx is designed to be used with a protective covering, the user is responsible for any damages caused from misuse, use under inappropriate conditions or from wrong power adaptor. 2. Please use the power adapter provided by the dealer, the manufacturer is not responsible for any damage caused from using power adapters not. 3. Do not shake the IP Power 9258xx in any fashion 4.
Table of Contents 1.) WELCOME.........................................................................................................................5 INTRODUCTION ..........................................................................................................................5 MINIMUM SYSTEM REQUIREMENTS ...............................................................................................5 2.) PRODUCT OVERVIEW .............................................................................
CGI HTTP COMMANDS ............................................................................................................. 30 A.) SET POWER COMMAND ................................................................................................................. 31 B.) READ POWER COMMAND ............................................................................................................... 31 C.) POWER DELAY ........................................................................................
1.) Welcome Introduction The 9258xx is an industrial grade 4 ports output remote power management through an Ethernet connection. This device can easily cooperate integrate with other devices and allow power control with your integrated system. And also control each output through each button locally.
2.) Product Overview Features 1. Embedded web server - No PC is required for it to work 2. 4 ports Industrial Dual Cut Relay design network controller. 3. Accessible with web browsers - IE , Google Chrome & Firefox. and also with the browser of smart phone - like iPhone and Android system. 4. Network protocols supported: Http, DDNS, DHCP, Virtual and Dynamic IP. 5. Detect " total Current " and " internal Temperature " 6. Power leakage protection- turn off as leakage over 3mA 7.
Package Contents 1.) 9258xx Unit x 1 2.) Installation CD CD contain manual, software, and documentation 3.) Power Cable (Optional) Standard PC power cable. Specification: 10AMP 18AWG 0.75 x 3C Spare Fuse in the socket. 4.
* 9258GE * 9258UK * 9258USA * 9258DK & 9258SW - 8- Ref#92550806002
3.) Interface Description Hardware Interface Power Output Simply plug & play in the device that you would like to power control. (Comes in different plug standards) 4 Buttons Control * ON/OFF Control : User can control each output ON/OFF by keep pressing each button for few seconds. The button light is RED as turn off or Blue as turn ON . Reset To revert to manufacturer default, please turn off the power input switch then keep hold button #1 & #2 .
Fix Ears ( Option ) User can fix 9258xx on with screws and ear.Notice: The fixed screws SPEC is type M3 and the length of the screw do not over 5mm. 4.) Setting up your Device Before we Start *Before setting up the device make sure of the following: 1.) All the package contents are all included if anything is missing please contact the dealer where the device was purchased from. 2.) Check that the power input cable is working correctly. 3.
9258xx Quick Installation 1.) Connect the Ethernet cable (RJ45) to the 9258xx to your local area network. 2.) Then connect the power cable into the power cable input of the 9258xx. 3.) Connect the device that you would like to control to the output plug on the top of the 9258xx. 4.) Open the IP Edit device search tool from the CD. 5.) The device will automatically be set to DHCP and will show on IP Edit. (Refer to Using IP Edit for more details) a.
Using IP Edit IP Edit is a search tool designed to search, configure, or access the IP Power 9258xx from a local networked computer. IP Power 9258xx Default Login / Password Default IP: 192.168.1.100 (When no DHCP is apparent) Default Login: admin Default Password: 12345678 1.) Insert the CD provided with the product 2.) Install the software IP Edit to the desktop of your computer. 3.) Open IP Edit by clicking on the icon 4.
For example: If you have the following information regarding the 9258xx and your network Your PC Network : Computer IP Address: 192.168.1.122 Gateway: 192.168.1.1 Sub Net mask: 255.255.255.0 Port: 80 Your 9258xx in IPEDIT : 9258xx IP Address: 192.168.100.34 Gateway: 192.168.100.1 Sub Net mask: 255.255.0.0 Port: 80 Since the IP Address of the 9258xx is : 192.168.100.34 You will need to make sure that the first 3 segments of your 9258xx IP Address must match the first 3 segments of your gateway IP.
Default Login : admin Default : 12345678 Notice : * User can click " REF " in IEPDIT to auto search proper IP setting for 9258xx .It will take few minutes to show the suggest wizard. Please click Apply as see the suggest wizard , click " yes " to ignore the remind message of IP in used and then type the username and password to change the IP setting.
* IP Power 9258xx must be port forwarded for IP Service to work correctly. 1.) Open IP Edit and Select the server that your 9258xx is designated to. 2.) Hit the green connect button on the top of IPEdit. 3.) Then type in the 9258xx Name that you have selected for the device and press the search button. 4.) Find your device and double click on the screen and a IE window will pop up connecting to your device. *Your device must be Port forwarded for the login screen to appear. 5.
5.) Web Interface The web interface on the IP Power 9258xx consists of 5 main sections. Power Controls, Scheduler, Ping , Setup and log out . * Power Controls: Turn off or Turn on the socket to provide power to the device. and also the current setting & illustration and temperature value * Scheduler: Schedule specific dates or time to active the IP Power 9258xx. * Ping Settings: Watchdog function to make sure your devices are responding normally.
Power Controls The Power Controls page include power control and current limit setup Current & Temp. value : show the consume current ampere and internal temperature at Celsius. Power control It is the panel where the user can directly turn off / on power to the attached device, set timers and name the outlet.
Name In the name section the device name can be set. Simply type in a name you would like for the deice and hit the apply button. Name does not support special characters (eg. ! *%) Control The control section allows the user to directly turn on or turn off the device. Select the control that you would like to execute and hit apply to apply the settings. This will turn the device on or off. Timer The timer allows the user to set an amount of time before a control is activated.
Current Value : Show the consume ampere of the device connected with 9258xx . The tolerance of the current measurement is plus or minus at 10% degree. Notice : For safety concern, the way of current detection is Non - Contact design , so the value at low current ( under 0.5amp) will be less accurate than at high current. Temperature Value : Show the internal temperature value at Celsius ( C ) .
Scheduler The power schedule offers flexibility so the user can easily schedule events to control the power of the device. Date: Enter the date in which the action will occur needs to be set. Time: Enter the time of the action will occur. Repeat: Select the frequency of this action. Just Once (Just one time) Everyday (Sunday thru Saturday) Workdays (Monday thru Friday) Weekend (Saturday, Sunday) Mon. & Thu. (Monday, Thursday) Tue. & Fri. (Tuesday, Friday) Wed. & Sat.
How to use: If you would like to turn on the device at 8:00AM and turn off the device at 8:00PM, the device may be set in this fashion. Ping Settings The Auto-ping functionality allows the 9258xx to check if the device have malfunctioned or needs to be restarted.
Some uses of this function would be for systems or computers that require a shut down time Delay after action (Seconds): The number of seconds it takes the attached devices to startup. Once those devices start, the Startup Action will be activated to continue pinging or stop pinging. Continue Ping: After start up Delay has been reached the start up action will either Continue Pinging or Stop Pinging Action: When the number of Ping Failures have been reached.
6.) When action delay has been reached the Action will be set off. Here we have set the 9258xx to Reset the device. 7.) Once the device has been reset the 9258xx will go into Startup Delay mode. In this case it is 3 seconds. 8.) After the startup delay mode has been reached the 9258xx will check the Startup Action whether to continue or stop pinging the device. Here we have it set to Continue. 9.) Then the process starts all over. 10.
System The system section allows you to make changes to the network information of the 9258xx. This includes changes to the IP Address, Gateway, Subnet Mast, and DNS. In additional under the system section you will also find other features including SNMP, Telnet, DHCP, Beeper configuration and more. IP Address: IP Address of the 9258xx device. Subnet Mask: The subnet mask information can be populated here. Default Gateway: Enter the gateway for the router. DNS: Enter the DNS information here.
Beeper: This will enable or disable the beep on the device as setting or receive any command. Leakage: Set as " Ignore " : 9258xx ignore if there is leakage in the power circuit and thi sis our default setting. Set as " Shutdown " : All the 4 power outputs will turn off if leakage over 3mA in this power circuit environment. This function also help user to check if leakage in this environment . User can disable this function by select " ignore" .
DDNS The DDNS Setup allows the user to setup the 9258xx with a DDNS server. This way instead of having to remember long IP Addresses, the user now can easily use a WWW link to connect to the device. This also is a good solution for users to have a dynamic IP Address where the IP continually changes and is not constant. Note: We recommend using free services like www.dyndns.com for this portion. The device may react differently to other ddns services.
E-mail This section is where email settings are inputted. After the information is populated the 9258xx will send notifications regarding the device when activated. Note: Not all email servers may be compatible with the 9258xx. Please see the FAQ section of the manual for a list of compatible Email providers with correct DNS information .
Change Password The change password function, will allow the user to change the current password of the device. Changing the password of the device: 1.) Type in the old password for the device 2.) Then type in the new password maximum of 8 characters 3.) Repeat the new password again 4.) Then hit the submit button. The login required option allows the user to choose whether they would like to disable login capabilities for the device.
IP Server Configuration The IP Server Configuration page is where the 9258xx can be configured to connect to IP service. IP service allows you to easily find your device of the web or of the google cloud server without the need to remember long IP Addresses. Instead you can find your device easily just by searching with the name of your device. Time The date and time settings allow the user to synchronize the 9258xx with their local time or a NTP server.
* For NTP to work correctly the DNS server must be configured correctly on your System configuration page Local Time: The local time gets the time of the PC that is currently being used. Logout Click on the Logout link after you finish each session of using the IP Power 9258xx. This will ensure that any other person that uses the device next will not be able to control the devices without logging in. 6.) Controlling the Device CGI HTTP Commands Http commands allow you to control the device with commands.
a.) Set Power Command The Set Power command allows you to control the devices on/off through the http commands. With this command you can integrate can integrate the 9258xx with any other system. Command format: http://ip:port/set.cmd?cmd=setpower+p61=1+p62=0+p63=1+p64=1 Outlet Output 1 Output 2 Output 3 Output 4 Power On 61 = 1 62 = 1 63 = 1 64 = 1 Power Off 61 = 0 62 = 0 63 = 0 64 = 0 Ex. For 4 Ports Control On / Off http://192.168.1.3/set.
p6xn means 2nd action of output x t6x=aa means delay aa seconds between the 2 actions ( aa range = 1 - 9999 seconds ) Ex. Turn ON Output #1 for 30 Seconds then turn Off http://192.168.1.3/set.cmd?cmd=setpower+p61=1+p61n=0+t61=30 Ex. Turn ON all 4 ports for 15 Seconds then turn Off http://192.168.1.3/set.cmd?cmd=setpower+p61=1+p61n=0+t61=15+ p62=1+p62n=0+t62=15+ p63=1+p63n=0+t63=15+ p64=1+p64n=0+t64=15 ( there is no space between command) d.
xx means Schedule item number : 1a, 1b, 2a, 2b, 3a, 3b, 4a, 4b yy=2006 ( Year 2006) mm=02 ( Month as February ) dd=16 ( Date as 16 ) hh=06 ( Hour as 06:00am) mn=02 ( Minute ) ss=16 (Second ) param=000 disable param=128 just once param=255 every days param=159 work day param=224 weekend param=137 mon&thu param=146 tue&fri param=164 wed&sat onoff=0 off onoff=1 on f.) Read current value - http://ip:port/set.
Help: The help command will provide all the commands available on the 9258xx. To get the commands in help type: help in the telnet protocol. Set power: The set power command allows the device to turn on and turn off ports on the device. To set power on the device type setpower p61=1: Port On setpower p61=0: Port Off Get power: The get power command gives you the current status of the device. To get power on the device type: 1 mean power on , 0 mean power off.
7.) Frequently Asked Questions (F.A.Q) Please visit our FAQ section on our website for the latest and most updated information on this product. You can visit our site at: www.Aviosys.com Q1: Which email providers are compatible with the 9258xx? Ans: If you are having problems getting your email address to work, we recommend try using the following email providers for the 9258xx . lavabit.com POP3: lavabit.com port: 110 SMTP: lavabit.com port: 25 inbox.com POP3: my.inbox.com port: 110 SMTP: my.inbox.
b.) Then make sure to power off the device within 60 seconds, by unplugging the device and then plugging it back in. c.) Then login to the device with the default login and password Default Login: admin Default Password: 12345678 Q4: How to I revert back to Manufacturers default settings? Ans: Hold the reset button for at least 5-7 seconds and you will hear two long beeping sound. Then use IP Edit to re-setup the device. Default IP: 192.168.1.