You can change the properties of the scan engine under Basic Configuration - Utility
Settings - AntiVir Engine - Properties.
The name of the Avira antivirus interface DLL must be entered in the Avira AV
Interface field. This DLL file represents the link between Avira AntiVir Exchange
and the virus scanner. This entry is pre-configured for all scan engines and must not
be changed! In the Parameter field, enter the parameter to be used by the virus
scanner for scanning.
To configure the virus scanner so that e-mails or attachments are cleaned when a
virus is detected, enable the Different clean parameter option and enter the
appropriate parameter in the Clean parameter field underneath.
Note: If you wish to use the scan engine for virus checking only, use the AntiVir job
Scanning with AntiVir Engine and disable the Remove malware option in the
Actions tab. If the virus scanner is to clean any infected files found, use the AntiVir
job Scanning and disinfection with AntiVir Engine. In this case, the option
Remove malware needs to be enabled and the actions to be performed for infected
mails must have been set.
Avira AntiVir Exchange 7