ACT-828 Wideband Dual-Channel Digital Receiver ACT-818 Wideband Single-Channel Digital Receiver User Guide MIPRO Electronics Co., Ltd. Headquarters: 814 Pei-Kang Road, Chiayi, 60096, Taiwan. Web: www.mipro.com.tw E-mail: mipro@mipro.com.
! IMPORTANT SAFETY INSTRUCTIONS ! 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9.
Wideband Digital Receivers Wideband Digital Receivers Contents Product Overview 1 Product Overview 3 Key Features 4 Receiver Controls and Indicators - Front Panel MIPRO's industry-leading digital wireless microphone system features compander-free technology ensures crystal-clear, natural vocal reproduction. The handheld transmitter microphone is equipped with a premium true condenser microphone capsule and provides warm and accurate transient detail.
Wideband Digital Receivers Wideband Digital Receivers Accessories Key Features The following accessories are included: ! ACT-828 is an EIA standard 1U dual channel and ACT-818 is a 1/2U single channel rack-mountable receiver with metal chassis. ! Full-color VFD (vacuum fluorescent display) for clear viewing all parameters. All controls are intuitive and easily accessible, allowing for quick and easy system setup via a single rotary control.
Wideband Digital Receivers Wideband Digital Receivers Receiver Controls and Indicators Receiver Controls and Indicators Front Panel Rear Panel ACT-818 ACT-818 PUSH FOR MODE SPDIF OUT ANTENNA B L REMOTE +8V DC BIAS OUT IN DC INPUT ANTENNA A (12~15V) +8V DC BIAS BA SQ BAND ADD GRP CH ACT-818 MHz ACT DIGITAL 1 ANT 2 RF AF WIRELESS RECEIVER ACT 3 4 1 PUSH FOR MODE 6 7 8 9 This connector can not be connected to telecommunication networks.
Wideband Digital Receivers Wideband Digital Receivers SQ: Squelch Setting Function Selection Rotary Controller: To set parameter values 8 parameters can be selected and programmed. See instructions below: SQ cursor starts flashing BA SQ BAND SQ GRP CH ANT EQ ADD GRP CH ADD ANT MHz ACT RF AF 8 EQ L Rotate clockwise to increase the setting by one bar Rotate counterclockwise to decrease by one bar Parameter Setting Procedures Operating Procedure: To Activate Parameters 1.
Wideband Digital Receivers Wideband Digital Receivers GRP: Group Setting CH: Channel Setting Refer to the supplied channel plan for your band to select a specific frequency.
Wideband Digital Receivers Wideband Digital Receivers ANT: Antenna A/B Setting EQ: Capsule Equaliser Setting Used for setup only. The EQ parameter is used to select from a range of simulated microphone capsule EQ's.
Wideband Digital Receivers Wideband Digital Receivers Encryption ( ADD: Address Setting for PC Remote Control For normal “stand-alone” use, this parameter does not need to be set. However when multiple receivers are to be used and controlled remotely using the MIPRO optional control software each receiver must be given a unique address. Always ensure that you set this address before adding the receiver to the remote control network.
Wideband Digital Receivers Wideband Digital Receivers Parameter Lock ( Decryption Instructions: 1. Press the rotary controller to activate and move the cursor to the icon. When the icon starts to flash and the word “YES” appears, the Encryption function is ready to be set. 2. Press and hold the rotary controller for approximately 3 seconds until the word changes from “YES” to “NO”. 3. Press the rotary controller once to confirm and save the selected “NO” to turn off the Encryption.
Wideband Digital Receivers Wideband Digital Receivers MIPRO'S Proprietary "ACT" Function and Operation Setting ACT Transmitter Frequency What is ACT? Press ACT button “ACT” stands for “Automatic Channel Targeting”. MIPRO developed and patented this innovative InfraRed (IR) technology in 2001. MIPRO was the first manufacturer in the industry to automatically synchronise the frequency selected on the receiver to any ACT handheld or bodypack transmitter in the same frequency band.
Wideband Digital Receivers Wideband Digital Receivers Computer Network Interface Operation BA: Transmitter Battery Meter (receiver display) 1. MIPRO ACT receivers are fitted with an ACT-BUS interface to enable remote control and monitoring via a PC-based control system. To enable this to communicate, an optional MIPRO interface adapter and software package is required. 2.
Wideband Digital Receivers Wideband Digital Receivers Troubleshooting General Tips for Improving System Performance ! Since the installation of the antenna influences the operating efficiency of the receiver, the most important rule is to minimise the distance as much as possible between the receiving antenna and the microphone for the best reception and performance. Symptom Solutions No Sound ! Power-on receiver & transmitter. ! Use MIPRO supplied antennas to ensure proper receiver sensitivity.
Wideband Digital Receivers Wideband Digital Receivers Troubleshooting Symptom Solutions RF Interference ! Press AutoScan button to locate a clear, interference-free channel. ! Use preset compatible channels in the same group when operating multiple systems. ! Place receivers away or remove the sources of RF interference like solid metal objects, electronic equipment & digital devices, dimmers, effect equipment, motors. ! Avoid operating a frequency on a local TV channel.