M MR RM M--660022PP User Manual “Modular” Seamless Multi-Format Switch Scaler with VGA, YPbPr, DVI and HDMI solutions 6x2 MRM-602P V.2014MRM-602P.
M MR RM M--660022PP COPYRIGHT AND TRADEMARKS All rights reserved by C&C TECHNIC TAIWAN CO., LTD. No part of this document may be reproduced in any form or by any means without written permission from the product manufacturer. Changes are periodically made to the information in this document. They will be incorporated in subsequent editions. The product manufacturer may make improvements and /or changes in the product described in this document at any time.
M MR RM M--660022PP BEFORE YOU BEGIN Follow all instructions marked on the device during using. Provide proper ventilation and air circulation and do not use near water. It is better to keep it in a dry environment. Place the device on a stable surface (example cart, stand, table, etc.). The system should be installed indoor only. Install either on a sturdy rack or desk in a well-ventilated place. Make sure the rack is level and stable before extending a device from the rack.
M MR RM M--660022PP TABLE OF CONTENTS Copyright and Trademarks...................................................................................................... 1 Before You Begin ..................................................................................................................... 2 Table of Contents ..................................................................................................................... 3 Chapter 1 Switcher System Overview ..................................
M MR RM M--660022PP 7.3.1 Video Configuration ...................................................................................... 34 7.3.2 Device Status Information ............................................................................ 34 7.3.3 LAN IP Function ............................................................................................ 35 7.3.4 Other Application........................................................................................... 36 Chapter 8 Troubleshooting..
M MR RM M--660022PP CHAPTER 1 SWITCHER SYSTEM OVERVIEW 1.1 Introduction The MRM-602P Switcher is a high performance, zero-second latency switching equipment with 6x2 transmission interfaces.
M MR RM M--660022PP 1.
M MR RM M--660022PP CHAPTER 2 FEATURES Supports seamless switching with zero second latency upon different resolutions. Flexible for having any combination of the preferred video (VGA, YPbPr, DVI or HDMI) modular cards and very easy to swap via 2 screws only. Up/down/cross converter equipped with VGA, YPbPr, DVI and HDMI inputs/ HDMI, VGA and Audio outputs. - Supports interlaced video to progressive video. (like 1080i => 1080P) Supports up convert.
M MR RM M--660022PP CHAPTER 3 SPECIFICATIONS Hardware Flexible Input Modular Card 1 x VGA, 1 x YPbPr, 1 x DVI, 3 x HDMI Females Output Connector 1 x HDMI Type A Female, 1 x VGA HD15 Female RS-232 Connector 1 x DB9 Female RS-485 Connector 2 LAN Connector 1 x RJ-45 Audio Port 1 x Audio Out Port, 4 x Audio In Ports 2 pins Dip Switcher 1 8 pins Dip Switcher 1 Power 100VAC~240VAC, 50/60Hz, internal, switching LED Indicators 10 x LED indicators specified for the connection is “Selected”.
M MR RM M--660022PP CHAPTER 4 DEVICE INSTALLATION The Switcher has a black metallic housing. It can be placed on a sturdy desk directly or installed on a bracket. See Figure 4-1 below: Figure 4-1 Mount the Device on a Standard Bracket with 1U Rack-mount CHAPTER 5 FRONT/REAR PANELS 5.1 Front Panel Figure 5-1 MRM-602P Switcher Front Panel The MRM-602P Switcher supports up to 6 switching keys on the Front Panel for indicating the connection status that allows you to switch connected sources quickly.
M MR RM M--660022PP Aspect: The MRM-602P Switcher allows you to configure the Aspect ratio of the output image including Full and 1:1 Aspect. Figure 5-2 Full Aspect When the Full aspect for the output image is configured, the FULL LED indicator on the front panel will become solid green. Figure 5-3 1:1 Aspect When the 1:1 aspect for the output image is configured, the 1:1 LED indicator will become solid green. Resolution: The MRM-602P Switcher supports you 720P and 1080P output resolutions.
M MR RM M--660022PP IR: Infrared receiver for the MRM-602P Switcher. The longest distance of your IR remote controller to receive the signals is about 12 meters.
M MR RM M--660022PP 5.2 IR Remote Controller Figure 5-5 IR Remote Controller Main Channel Port selection: Press the Number#1~6 button to select the key channel on the front panel. Example: Press the “5” button on the Remote controller specified the input signal of the key on the front panel comes from the channel#5 (HDMI INPUT 5 interface on the rear panel).
M MR RM M--660022PP 5.3 Rear Panel Figure 5-6 MRM-602P Switcher Rear Panel The MRM-602P Switcher supports up to 6 input and 2 output jacks on the rear panel, each female terminal separately form the signal input and output jacks. The flexible modules cards specified as “INPUT1” (VGA+AUDIO), “INPUT2” (YPbPr+AUDIO), “INPUT3” (DVI+AUDIO) and “INPUT4~6” (HDMI interfaces) are for signals input.
M MR RM M--660022PP DIP Switcher: 8 pins DIP and 2 pins DIP switchers for connected configurations. For more information, refer to 6.5 Ports and Switchers. 8 pins DIP switchers: Pin 1~Pin5: ID Pin 6: Master/Slave Pin 7: RS-232/LAN Pin 8: IP RESET 2 pins DIP switchers (DIP Switch RS-485 Terminator): RS-485 Terminator for ON/OFF VGA OUT connector: The VGA OUT connector is connected to the Monitor, HDTVs or other output devices through a VGA cable.
M MR RM M--660022PP DVI connector host assignment: Pin # Signal Pin # Signal 1 TMSD data 2- 13 TMDS data 3+ 2 TMDS data 2+ 14 +5V 3 TMDS data 2/4 shield 15 Ground 4 TMDS data 4- 16 Hot plug detect 5 TMDS data 4+ 17 TMDS data 0- 6 DDC clock 18 TMDS data 0+ 7 DDC data 19 TMDS data 0/5 shield 8 Analog vertical sync 20 TMDS data 5- 9 TMDS data 1- 21 TMDS data 5+ 10 TMDS data 1+ 22 TMDS clock shield 11 TMDS data 1/3 shield 23 TMDS clock+ 12 TMDS data 3- 24 TMDS
M MR RM M--660022PP CHAPTER 6 CONNECTIONS Figure 6-1 MRM-602P Connections 6.1 Input/Output Connections Use the VGA/YPbPr/DVI/HDMI connecting cable to connect the Input modular card (INPUT1 ~ INPUT 6) on the rear panel to the output connector of the sources (CD/DVD player/Camera/ PS3/STB/PC). And use the HDMI or VGA connecting cable to connect the output connector (HDMI OUT/VGA OUT) on the rear panel to the input connector of the HDMI TV, displays, multiplexers and so on.
M MR RM M--660022PP Figure 6-3 Output Connection 17
M MR RM M--660022PP 6.2 Switcher System Remote Control Use the RS-232 connecting cable to connect the computer serial communication port (COM1 or COM2) to the RS-232 communication port of the MRM-602P Switcher. The computer can then be used to control the MRM-602P Switcher after installing of application software. Aside from using the front panel keys for switching operation, you are also permitted to use the RS-232 connection port for a remote operation.
M MR RM M--660022PP 6.3 IR Connection The MRM-602P Switcher provides you an IR receiver for more convenient to react to the controller. If it is difficult for you to aim at IR receiver on the front panel due to the location of Switcher, please connect it to the IR port located on the rear panel for optional position. Figure 6-6 IR Extended Aiming 6.4 Power Connection Use the included power cord to connect from the power port on the rear panel of the MRM-602P Switcher to the outlet.
M MR RM M--660022PP 6.5 Ports and Switchers The MRM-602P Switcher provides standard RS-232 serial communication port as well as LAN for remotely managing , and Dip Switch for locally setting. Besides the front panel is ideally for the local switching, managing and setting operation. 6.5.1 RS-232 The RS-232 Pin functions are described as below: Pin No.
M MR RM M--660022PP Figure 6-8 (b) Figure 6-9 The Switcher RS-232 port is defined by DCE.
M MR RM M--660022PP 6.5.2 RS-485 RS-485 is a standard defining the electrical characteristics of drivers and receivers for use in balanced digital multipoint systems. Digital communications networks implementing the RS-485 standard can be used effectively over long distances and in electrically noisy environments. The Switcher support up to two RS-485 ports allows you to control more than one relative Device.
M MR RM M--660022PP 6.5.3 LAN Port The MRM-602P Switcher supports a network RJ-45 registered jack using 8P8C modular connector, which specifies the physical male and female connectors as well as the pin assignments of the wires in a telephone cable. (A common LAN cable is available.) Figure 6-12 LAN Port 6.5.4 DIP Switcher for 8 Pins Figure 6-13 DIP Switch for 8 Pins A. DIP Switcher Pin 1 to 5: Switch to down (ON) is specified for “0”, on the other hand to up (OFF) is specified for “1”.
M MR RM M--660022PP C. DIP Switcher Pin 7: Switch between RS-232 port and LAN port connection. The default value is “OFF”. ON: RS-232 OFF: LAN D. DIP Switcher Pin 8: Reset the web server IP address to 192.168.0.3, the default value is “OFF”. The steps are as below: 1. Please adjust the pin8 to ON and re-start the Switcher. 2. After the Switcher re-starts about 10 seconds, shut down your equipment. 3. For a normal operation, please adjust the pin8 to OFF, then power on the Switcher again.
M MR RM M--660022PP 14 0E 01110 ON OFF OFF OFF ON 15 0F 01111 ON OFF OFF OFF OFF 16 10 10000 OFF ON ON ON ON 17 11 10001 OFF ON ON ON OFF 18 12 10010 OFF ON ON OFF ON 19 13 10011 OFF ON ON OFF OFF 20 14 10100 OFF ON OFF ON ON 21 15 10101 OFF ON OFF ON OFF 22 16 10110 OFF ON OFF OFF ON 23 17 10111 OFF ON OFF OFF OFF 24 18 11000 OFF OFF ON ON ON 25 19 11001 OFF OFF ON ON OFF 26 1A 11010 OFF OFF ON OFF ON 2
M MR RM M--660022PP CHAPTER 7 SWITCHER APPLICATION SOFTWARE 7.1 Software Introduction The 《AV Matrix》 matrix control software applies to different input/output matrixes. 7.1.1 Software Description The 《AV Matrix》 matrix testing software is an application tool developed for matrix testing and application. The software operation environment is as below: Window7/98/2000/NT/XP/VISTA operating systems (For more information, please refer to:/software/readme.txt before the installation.
M MR RM M--660022PP 7.1.3 Connect MRM-602P and PC You must power off the MRM-602P Switcher. Then, connect the Switcher RS-232 port to the PC RS-232 port with the bundled communication cable. And make sure the DIPs on the rear panel are set to Master and RS-232. (Refer to the previous section 6.5.1 RS-232) 7.2 Switcher Configuration After finishing installation, click to active AV Matrix Application. In the “Options” window, select the connected PC Port number and Baud rate, and then click “OK”.
M MR RM M--660022PP The Device ID is based on the DIP of switcher located on the rear panel. Slide the scrollbar on the lower left area of main window to view all contents (including ID, Name, Audio, Video, Input, Output, Memory, VI Plug, AI Plug, VO Plug, AO Plug, EDID Type, Volume, Bass, Treble, Subwoofer, Delay, Delay Unit, Max Delay and Version) as described below: ID: Specify the ID address of Switcher switching device. Name: The name of Switcher switching device.
M MR RM M--660022PP Audio Tab: Click the “Audio” tab to show the audio related configuration window. Video Tab: Click the “Video” tab to show the video related configuration window. Disconnect: To disable the connections. After you had configured the connection between input and output ports, you can click this button to disable the connections Select all: Click this button to select all output ports including HDMI OUT, VGA OUT and AUDIO OUT. Video check box: Used for video configurations.
M MR RM M--660022PP 7.2.2 Disconnect Function Key Disable all the unused output ports.
M MR RM M--660022PP 7.2.3 Options Function Activation Function: In the main configuration menu, select Options to prop-up the Options Window as shown in Figure 7-5(a) Figure 7-5 Options(a) Figure 7-5 Options(b) Function Description: Linking Methods: In “Port number” select one of the COM ports as shown in Figure 7-5(b)for a example; in “Baud rate” select 9600 for signal transmission as shown in Figure 7-5(a) 7.2.
M MR RM M--660022PP 7.3 LAN Web Configuration Open the Browser on your PC, key in the default IP address: http://192.168.0.3 to login the AV MATRIX Control configuration window. Once the default IP address is changed, please use the changed IP to login. The software controls signal connection between the corresponding input port and output port as required. The LAN main configuration window is as below: Figure 7-6 LAN Web Configuration Window MRM-602P Switcher is integrated HDMI switching equipment.
M MR RM M--660022PP Upgrade: Use for firmware upgrade. For more information, refer to Appendix B Firmware Upgrade . Options: Allow you to configure the IP address. Save: Click this button to save the connected combinations output and input ports. It also includes the present input/output switching relations and all settings. All Output: A Hot Key for you to set the same value to all output channels. Select the All Output check box, then key in example “4” value in the channel 1 output.
M MR RM M--660022PP 7.3.1 Video Configuration For video configuration, click Video button directly to pop-up “Video Settings” window. Figure 7-8 Video Operation In “Video Settings” window, you can click Change button to switch EDID Output1 and Default port. Figure 7-9 Video Configurations – Default port used The LCD will appear FIX when you switch to Default, alternately, it will appear OUT1 with Output1 selection. If the Switcher does not support video function, it will appear “Not Support”.
M MR RM M--660022PP Figure 7-12 Device Status Information 7.3.3 LAN IP Function In the main configuration menu, select Options button to pop-up the Browser ex. “Windows Internet Explorer” dialog box, click “OK” to show the IP configuration window as shown in Figure 7-13. Figure 7-13 Network Settings In the “Network Settings” window, you can set the IP information by yourself (Fix IP) or click the Enable DHCP check box to get the IP from the DHCP (Float IP).
M MR RM M--660022PP 7.3.4 Other Application The software utility will show you at least 32 units Device ID and Name. You can click the Console down list to select which device that you want to configure output /input values. The entire connected Device name will be showed on the Console List as Figure 7-14. For this model, the software utility will show at least 1 up to 32 devices. The example as below shows you an ID: 0 for the Name: MRM-602P Switcher presently.
M MR RM M--660022PP CHAPTER 8 TROUBLESHOOTING 1. What to do if LCD is fail in display? Answer: Check the connection of power cord is not loosening and the power cord is in a good status having no any damage. Check the power source is normally. 2. What to do if the Switcher front panel keys switching not responsive? Answer: The Switcher front panel keys employ scanning testing and require longer response time. Press the keys for 2 seconds and then release.
M MR RM M--660022PP 6. What to do if the Switcher panel keys and communication ports are out of order? Answer: Check if the equipment power input is in good contact and the computer communication ports are in good order. If yes, it could be some internal failure of the product, please send for repair by qualified technical engineer. 7. What to do if operation and function failure occurred? Answer: Check if the equipment and the Switcher system are in proper connection.
M MR RM M--660022PP APPENDIX A IR CONTROLLER The MRM-602P Switcher supports a remote controller allows you to remote switch which Input signal by passing through to current output with an extended connection - IR receiver/transmitter. The signal for controller is only available to the IR receiver connected to the IR hole located on the rear panel. Channel Port selection: Press the Number#1~6 button to select the channel that you want to appear on the output displayer.
M MR RM M--660022PP APPENDIX B FIRMWARE UPGRADE This Chapter will introduce you how to upgrade firmware on your web browser. For firmware upgrade, you have to upload the firmware file to your web server and then upload it to your device from web server. Follow the steps as below to upgrade the firmware: 1. Open the Browser on your PC, key in the default IP address: http://192.168.0.3 to login the AV MA TRIX Control configuration. Click “Upgrade” to begin firmware upgrade. 2.
M MR RM M--660022PP For 0: General selecting, you have to adjust the switcher ID on the real panel to “0” that means the device with ID “0” will be upgraded. 4. For 1: Switcher Device will allow you to select target device based on ID 0 to 31 for upgrading firmware. 5. Select “2: Switcher I/O Module” will allow you to upgrade I/O modules. You have to decide which device you want to configure, and then select the suitable Device ID and I/O Module from the drop-down menu. Click “Update” to upgrade.
M MR RM M--660022PP 6. After finishing firmware upgrade successfully, “Firmware Upgrade to Device Success” information will appear as below. Besides, the firmware upgrade will not stop even though the web connection is fail suddenly. Please check with the LCD screen to confirm the firmware upgrade has been finished successfully or wait at least 2 minutes then power off to restart your PC. 7. If there is a firmware already exists on the web server during firmware upgrade.
M MR RM M--660022PP APPENDIX C RS-232 COMMUNICATION PROTOCOL This AV Matrix RS-232 communication protocol uses fixed length with 5 bytes of information as define below. The default baud rate is 9600 bps, no parity, 8 data bit and 1 stop bit. Command timeout is 300 ms, and byte to byte timeout is 30ms. Use the RS-232 connecting cable to connect the computer serial port to the RS-232 communication port of the Switcher device. The computer can control the Switcher device via RS-232.
M MR RM M--660022PP D-1.2 Request Byte Request Byte (RB) Name Bit 7 Bit 6 RB 0 0 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Request Type (0 - 63) Request Type: Please refer to "Table - Host Request List". 0: Reserve, Always 0.
M MR RM M--660022PP 0x15 Request Audio Output Bass Output Memory B 0x16 Control Audio Output Treble Output Level A 0x17 Request Audio Output Treble Output Memory B 0x18 Control Audio Output Subwoofer Output Level A 0x19 Request Audio Output Subwoofer Output Memory B 0x1C Control Audio Output Delay Low Output Delay1 A 0X1D Request Audio Output Delay Low Output Memory B 0X1E Control Audio Output Delay High Output Delay2 A 0X1F Request Audio Output Delay High Output
M MR RM M--660022PP D-1.3 Index Byte Index Byte (IB) Name Bit 7 Bit 6 Bit 5 Bit 4 IB Bit 3 Bit 2 Bit 1 Bit 0 Index Index: Please refer to "Table - Host Request List" and "Table - Command Index List". Table – Command Index List Index Description Output The output that will be selected. (Port 1 = 1, Port 2 = 2… Port n = n) 0: All outputs Input The input that will be selected. (Port 1 = 1, Port 2 = 2… Port n = n) 0: All inputs Setting - The setting type that will be selected.
M MR RM M--660022PP D-1.4 Value Byte Value Byte (VB) Name Bit 7 Bit 6 Bit 5 Bit 4 VB Bit 3 Bit 2 Bit 1 Bit 0 Value Value: Please refer to "Table - Host Request List" and "Table - Command Value List". Table – Command Value List Value Description Input The input that will be connected.
M MR RM M--660022PP D-1.5 CRC Byte CRC Byte (CB) Name Bit 7 Bit 6 CB Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 CRC (cyclic redundancy check) CRC: Host must send CRC code to follow the last byte.
M MR RM M--660022PP CRC Calculation CRC 0 = 0 (initial value) CRC 1 = CRC_ TABLE [CRC 0 ^ Byte 1] = CRC_ TABLE [0x00 ^ 0x20] = 0x23 CRC 2 = CRC_ TABLE [CRC 1 ^ Byte 2] = CRC_ TABLE [0x23 ^ 0x01] = 0x9F CRC 3 = CRC_ TABLE [CRC 2 ^ Byte 3] = CRC_ TABLE [0x9F ^ 0x06] = 0x8D CRC 4 = CRC_ TABLE [CRC 3 ^ Byte 4] = CRC_ TABLE [0x8D ^ 0x03] = 0x93 D-2 Device ACK Packet When the device receives supported commands comes from the host, and then will response with following ACK: Table – ACK Type List Ack Type Byte 1
M MR RM M--660022PP D-2.2 ACK Type B ACK Byte + LB + Index1 + Value1 + Index2 + Value2 +…..+ CRC Byte Name Bit 7 Bit 6 Bit 5 AB ACC 0 0 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Device ID (0 – 31) LB Length for the total data bytes (Index + Value) IB n Index VB n Value … … CB CRC AB & CB: These are the same as the ACK Type A. LB: LB value is equal to the total data bytes (Index + Value), not include the CRC byte.
M MR RM M--660022PP D-2.3 ACK Type C ACK Byte + LB + Data 1 + Data 2 + CRC Byte (Total 5 Bytes) Name Bit 7 Bit 6 Bit 5 AB ACC 0 0 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Device ID (0 – 31) LB Length for the total data bytes (This byte is always 2) DB 1 Data 1 DB 2 Data 2 CB CRC AB & CB: These are the same as the ACK Type A. LB: LB value is always 2 (Data 1 + Data 2). Not include the CRC byte. DB: Data Bytes as define below.
M MR RM M--660022PP D-2.4 ACK Type D ACK Byte + LB + INF + OP + IP + Name 1 + Name 2 + Name 3 +.....+ CRC Byte Name Bit 7 Bit 6 Bit 5 AB ACC 0 0 LB Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Device ID (0 - 31) Length for the total data bytes (INFO +.....+ Name n) INFO Audio Video Extend 0 Total Memory Location (0 - 15) OP Total Output Port IP Total Input Port NB 1 Device Name (ASCII code) … … NB n Device Name (ASCII code) CB CRC AB & CB: These are the same as the ACK Type A.
M MR RM M--660022PP D-2.5 ACK Type E ACK Byte + LB + EXTI + VIDI + AUDI + PLUG +.....+ CRC Byte Name Bit 7 Bit 6 Bit 5 AB ACC 0 0 LB Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Device ID (0 - 31) Length for the total data bytes (EXINF +.....+ DTMAX) LBMAX EXINF 0 0 0 0 0 FWVER VEINF EDID 0 0 0 0 0 0 0 AEINF DTUF DELAY 0 0 SW TRE BASS VOL PLUG 0 0 0 0 AOPD VOPD AIPD VIPD DTMAX Delay Time Maximum (unit: 100 ms) CB CRC AB & CB: These are the same as the ACK Type A.
M MR RM M--660022PP BASS - Bass command flag. (Request 0x14 and 0x15) 1 - Support Bass command. 0 - Not support Bass command. TRE - Treble command flag. (Request 0x16 and 0x17) 1 - Support Treble command. 0 - Not support Treble command. SW - Subwoofer command flag. (Request 0x18 and 0x19) 1 - Support Subwoofer command. 0 - Not support Subwoofer command. DELAY – Audio delay command flag. (Request from 0x1C to 0x1F) 1 - Support audio delay command. 0 - Not support audio delay command.