Cyclades-PR1000 Access Router Installation Manual

Cyclades-PR1000
25Chapter 4 - Step-by-Step Instructions
Please read the entire example and follow the instructions before turning the router on. The router is
programmed to log the super user off after 10 minutes of inactivity. All data not explicitly saved to
memory is then lost. Collecting the data
while
configuring the router will likely cause delays and
frustration.
STEP ONE
The first step is to determine the parameters needed to configure the Ethernet interface (ETH0). The parameters
in the Network Protocol Menu (IP) are shown in Figure 4.2. Fill in the blanks for your application in the right-most
column. These parameters will be entered into the router later, after all parameters have been chosen. Each
parameter in this menu is explained in more detail in chapter 5 of the Installation Manual.
Menu
CONFIG=>INTERFACE=>ETHERNET=>NETWORK PROTOCOL=>IP
Parameter Example Your Application
Active or Inactive Active enables IP communication (IPX
and Transparent Bridge are not used in
this example).
Interface Numbered
/Unnumbered
Numbered
Primary IP Address 192.168.0.1
Subnet Mask 255.255.255.0
Secondary IP
Address
0.0.0.0 for none.
IP MTU Use the preset value, 1500. This
determines whether or not a given IP
datagram is fragmented.
this table continued
FIGURE 4.2 ETHERNET NETWORK PROTOCOL MENU PARAMETERS