Keyboard is inoperable after switching channels
  Try changing the keyboard scan set for that channel by using the keyboard command 
sequence <Kn>. For more information, see Operations.
  If you are operating in secure mode, verify your keyboard and mouse privileges. If  
the problem persists, call Avocent Technical Support.
Characters on screen do not match keyboard input
  Try changing the keyboard scan set for that channel by using the keyboard 
command sequence <Kn>. For more information, see Operations. If the problem 
persists, call Avocent Technical Support.
No keyboard, video or mouse 
  Verify that the cable connecting the two units together on the expansion unit 
is functioning properly; verify that the base unit is correctly connected on both 
ends. For additional is information, see Installation. If the problem persists, 
contact Avocent Technical Support.
OSD menu does not “pop-up”
  Verify that you are pressing the Control key twice within one second. If the 
problem persists, contact Avocent Technical Support. 
Unable to change channels using OSD
  Verify that the channel is powered. Check the address confi gured in OSD. If the 
computer is powered and the address is correct, call Avocent Technical Support.
Administrator password is forgotten
  Call Technical Support.
User password is forgotten
  Contact your system administrator.
General Keyboard/Video Problems
  If the building has 3-phase AC power, ensure that the computer, the AutoView 
and the monitor are on the same phase. Best results are obtained when they 
are on the same circuit.
  Use only Avocent-supplied cable. Avocent warranties do not apply to damage 
resulting from user-supplied cable. Do not use a 2-wire extension cord in any 
Avocent product confi guration.
  Test AC outlets at computer, AutoView and monitor for proper polarity and 
grounding. Use only with grounded outlets at the computer, AutoView and 
monitor. When using a backup power supply (UPS), power the computer, 
AutoView and the monitor off the supply.
System lockup during paired operation
  If there is no keyboard, mouse or push-button channel selection function, try to 
bring up the OSD menu. If it activates, reselect your channel and verify that the 
channel functions normally. If the problem persists, contact Technical Support.
  If the OSD menu does not activate, verify that the serial cable and video cables 
are securely attached to both boxes. If not, reattach and try the OSD menu again. 
If the problem persists, contact Technical Support.