94 DSView Installer/User Guide
You may easily adjust your video parameters by clicking on the Auto Adjust Video button in the
Manual Video Adjust dialog box, which instructs the DS appliance/DSR switch to optimize the
video to ideal settings.
NOTE: A green screen with yellow lettering may appear during auto-adjustment.
Refresh Image
NOTE: You may also select View - Refresh from the Video Viewer window menu to refresh the image.
Clicking the Refresh Image button in the Manual Video Adjust dialog box will completely
regenerate the digitized video image.
Video Test Pattern
Clicking the Video Test Pattern button in the Manual Video Adjust dialog box will toggle a display
a video test pattern. Click the Video Test Pattern button again to toggle back to a normal
video image.
Adjusting Mouse Options
The Video Viewer window mouse options affect cursor type, cursor mode, scaling, alignment and
resetting. Mouse settings are device-specific; that is, they may be set differently for each device.
NOTE: If the device does not support the ability to disconnect and reconnect the mouse (almost all newer PCs
do), then the mouse will become disabled and the device will have to be rebooted.
Cursor type
The Video Viewer window offers five appearance choices for the local mouse cursor. You may
also choose no cursor or the default cursor.
NOTE: You may define the default cursor type that will appear when a Video Viewer window is opened. See
Changing the System Settings on page 58 for more information.
Single Cursor mode (Windows operating system only)
In Single Cursor mode, the display of the local (second) cursor in the Video Viewer window is
turned off and only the target device’s mouse pointer will be visible. The only mouse movements
that will appear are those of the target device’s remote cursor. When Single Cursor mode is active,
relative mouse movements are sent to the target device instead of the absolute mouse cursor
locations sent in regular desktop (two-cursor) mode.