56 DSView Installer/User Guide
Rebooting and Changing Power States
If you have Administrator privileges, you may perform a warm reboot on a DS appliance at a
remote location.
To reboot a remote DS appliance:
1. Select the DS appliance in the DSView management software window.
2. Select Tools - Reboot.
- or -
Right-click and select Reboot from the shortcut menu.
- or -
Click the Reboot toolbar icon.
A confirmation dialog box will appear.
3. Click OK to reboot the remote DS appliance.
Changing the SPC device power state
NOTE: To change the power state of a target device powered by an SPC device, the SPC device must be
connected to a CPS810 appliance or CPS1610 appliance. For more information on connecting an SPC device to
a CPS appliance, see the SPC Installer/User Guide.
The power state of any device powered by an SPC device outlet may be turned on or off. The SPC
device outlet may also be used to reboot a server.
To change the SPC device power state:
1. Load the DSView management software. This will activate the Node Manager and display a
list of DS appliances with ports linked to SPC devices that you may access.
2. From the DSView management software window, select a port or channel associated with an
SPC device outlet or an unassociated SPC device outlet, then right-click on the item and select
Power State from the shortcut menu. This will open the Power State dialog box with the cur-
rent power state of the SPC device outlet selected.
The following items appear in the dialog box when the corresponding conditions occur:
If the selected port or channel has an associated link to an SPC device outlet or if an unassoci-
ated SPC device outlet was selected, its current power state will appear in the dialog box.
If there is an associated link for the selected port or channel, the name of the outlet(s) will
appear in the dialog box.
If there is an associated server for a selected outlet, the name of the server will appear in the
dialog box.