Chapter 5: DSWebview Browser-Based Software 81
You may override this value within the DSView management software window. If you specify a
new time-out value, it will be used the next time the DSView management software is started. See
Sharing a Device Session on page 80 for more information.
Rebooting and Changing Power States
If you have Administrator privileges, you may perform a warm reboot on a DS appliance at a
remote location.
To reboot a remote DS appliance:
1. Place your cursor over the DS appliance in the DSWebview software window and then select
Reboot from the floating option menu.
A confirmation dialog box will appear.
2. Click OK to reboot the remote DS appliance.
Changing the SPC device power state
NOTE: To change the power state of a target device powered by an SPC device, the SPC device must be
connected to a CPS810 appliance or CPS1610 appliance. For more information on connecting an SPC device to
a CPS appliance, see the SPC Installer/User Guide.
The power state of either a particular server, SPC device, CPS appliance, EVR1500 environmental
monitor or generic appliance powered by an SPC device may be turned on or off. The SPC device
may also be used to reboot a server.
To change the SPC device power state:
1. Load the DSWebview software. This will activate the Node Manager and display a list of DS
appliances with ports linked to SPC devices that you may access.
2. From the DSWebview software window, place your cursor over an SPC device, then select
Power State from the floating option menu. This will open up the Status: <current power state>
dialog box.
3. Do one of the following:
•Click On to turn the SPC device on.
•Click Off to turn the SPC device off.
•Click Reboot to reboot the SPC device and any attached servers. The SPC device On or
Off state will remain the same as the last time the Power State dialog box was accessed.
4. A confirmation dialog box displays. Click Yes to perform the selected action.
NOTE: One DS port may have multiple SPC device ports associated with it. Any on, off or reboot operation you
choose to perform to one SPC device port associated to a specific DS port and target server occurs to every
SPC device port associated to the DS port and target server.