40 Cyclades® CS Console Server Installation, Administration and User Guide
Figure 6.6: Expert - New/Mod SNMP v3 Configuration Dialog Box
To configure SNMP:
1. Go to Networks - SNMP. The SNMP form appears.
2. To enable any version of SNMP, perform the following:
a. To add an SNMPv1/SNMPv2 entry, press the Add button under the SNMPv1/SNMPv2
Configuration table.
b. To add an SNMPv3 entry, press the Add button at the bottom of the SNMPv3
Configuration table. The New/Modify SNMP Daemon Configuration dialog box appears.
3. For SNMP v1 or v2 configuration, enter or change the following information:
a. Enter the community name in the Community field.
b. Enter the source IP address or range of IP addresses in the Source field.
4. For SNMP v3 configuration, enter or change the following information:
a. Enter the user name in the User name field.
b. Enter the password in the Password field.
NOTE: The SNMPv3 password must be fewer than 31 characters.
5. For any version of SNMP, perform the following:
a. Enter the unique object identifier for the object in the OID field.
b. Choose Read Only or Read/Write from the Permission field.
6. Click OK.
7. Click apply changes.
NOTE: In addition to SNMP configuration described in this section, you need to make sure SNMP service is
enabled and configured for one or more serial ports in order to send SNMP traps.