Supported by: ® Technology Corporation www.RackitTechnology.com Supported by: ® DS R® Switch Technology Corporation www.RackitTechnology.com Installer/User Guide For Technical Support: www.avocent.
INSTRUCTIONS This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. DANGEROUS VOLTAGE This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
DSR® Switch Installer/User Guide For models: DSR2035 and DSR8035 Avocent, the Avocent logo, The Power of Being There, DSR, DSView, Dambrackas Video Compression, AVWorks and OSCAR are registered trademarks of Avocent Corporation or its affiliates. All other marks are the property of their respective owners. © 2005 Avocent Corporation. All rights reserved. 590-535-616A.
USA Notification Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
iii TABL E OF CONTEN TS Table of Contents List of Figures ................................................................................................................ vii List of Tables ................................................................................................................... ix Chapter 1: Product Overview.......................................................................................... 1 Features and Benefits ...........................................................
iv DSR2035/8035 Switch Installer/User Guide Chapter 3: Local Port Operation................................................................................... 21 Controlling Your System at the Local Port...................................................................................... 21 Viewing and selecting ports and servers .................................................................................. 21 Viewing the status of your DSR2035/8035 switching system ..................................
Table of Contents v Chapter 6: Terminal Operations ................................................................................... 75 The Console Menu ........................................................................................................................... 75 Network Configuration .................................................................................................................... 75 Other Console Main Menu Options.......................................................
vi DSR2035/8035 Switch Installer/User Guide
vii L IS T O F F IG URE S List of Figures Figure 1.1: Example DSR2035/8035 Switch Configuration ............................................................. 3 Figure 2.1: Basic DSR2035/8035 Switch Configuration (Showing the DSR8035 Model)................ 7 Figure 3.1: OSCAR Interface Main Dialog Box.............................................................................. 22 Figure 3.2: OSCAR Interface Setup Dialog Box .............................................................................
viii DSR2035/8035 Switch Installer/User Guide
ix L I ST OF T A B L ES List of Tables Table 3.1: Main Dialog Box Functions ........................................................................................... 22 Table 3.2: OSCAR Interface Status Symbols ................................................................................... 23 Table 3.3: OSCAR Interface Navigation Basics .............................................................................. 25 Table 3.4: Setup Features to Configure the OSCAR Interface.........................
x DSR2035/8035 Switch Installer/User Guide
1 CHA PTER 1 Product Overview Features and Benefits Avocent DSR® switches combine analog and digital technology to provide flexible, centralized control of data center servers and virtual media, and to facilitate the OA&M (operations, activation and maintenance) of remote branch offices where trained operators may be unavailable. They provide enterprise customers with a significant reduction of cable volume, secure remote access and flexible server management from anywhere at anytime.
2 DSR2035/8035 Switch Installer/User Guide Reduce cable bulk With server densities continually increasing, cable bulk remains a major concern for network administrators.The DSR2035/8035 switches significantly reduce KVM cable volume in the rack by utilizing the innovative DSRIQ module and single, industry-standard Unshielded Twisted Pair (UTP) CAT 5 cabling. This allows a higher server density while providing greater airflow and cooling capacity.
Chapter 1: Product Overview 3 DSR2035/8035 Switch Ethernet DSView Software Server Modem Telephone Network Analog User (OSCAR® Graphical User Interface) Figure 1.
4 DSR2035/8035 Switch Installer/User Guide Safety Precautions To avoid potential video and/or keyboard problems when using Avocent products: • If the building has 3-phase AC power, ensure that the computer and monitor are on the same phase. For best results, they should be on the same circuit. To avoid potentially fatal shock hazard and possible damage to equipment, please observe the following precautions: • Do not use a 2-wire power cord in any Avocent product configuration.
5 CHA PTER 2 Installation DSR Switch Connectivity The DSR2035/8035 switching system requires connectivity to a server running the DSView 3 software. DSView 3 software allows a user to view and control target devices (one at a time) attached to the DSR2035/8035 switching system. For more information on the DSView 3 software, see the DSView Installer/User Guide.
6 DSR2035/8035 Switch Installer/User Guide information on how the DSR switch uses TCP/IP, see the DSView Installer/User Guide or DSView 3 Software Online Help. Installing the DSR switch The general procedure for setting up and installing the DSR2035/8035 switch is as follows: • Unpack the DSR2035/8035 switch and verify that all components are present and in good condition. See the Getting started section in this chapter.
Chapter 2: Installation Telephone Network Modem Analog User External Network Virtual Media Digital User DSR8035 Switch Power Cord SPC Port Connection Ports 1-32 SPC Port Connections SPC Power Control Device SPC Power Control Device Local USB Connections Servers 1-32 * To open a virtual media session with a server, the server must first be connected to the switch using a virtual media-capable DSRIQ module (USB2 or USB2L). DSRIQ Modules PS/2, USB*, Sun and serial adaptors are available.
8 DSR2035/8035 Switch Installer/User Guide Setting up your network The DSR2035/8035 switching system uses IP addresses to uniquely identify the switch and the target devices. The DSR2035/8035 switch supports both Dynamic Host Configuration Protocol (DHCP) and static IP addressing. Avocent recommends that IP addresses be reserved for each switch and that they remain static while the DSR2035/8035 switches are connected to the network.
Chapter 2: Installation 9 Connecting the DSR2035/8035 switch hardware NOTE: The DSR2035/8035 switch may be rack mounted in a 1U configuration. The DSR2035/8035 switch does not support a 0U configuration. To connect and power up your DSR2035/8035 switch: 1. Power down the target device(s) that will be part of your DSR2035/8035 switching system. Locate the power cord that came with the DSR2035/8035 switch. Plug one end into the power socket on the rear of the DSR2035/8035 switch.
10 DSR2035/8035 Switch Installer/User Guide 8. (Optional) To configure the DSR2035/8035 switch using the console menu interface, use the second supplied ribbon cable and RJ-45 to DB9 (female) adaptor to connect a terminal or a PC that is running terminal emulation software (such as HyperTerminal®) to the SETUP port on the back panel of the DSR2035/8035 switch. The terminal should be set to 9600 bits per second (bps), 8 bits, 1 stop bit, no parity and no flow control. Otherwise, proceed to the next step.
Chapter 2: Installation 11 Verifying the Connections DSR2035/8035 switch The front panel of the DSR2035/8035 switch features LEDs indicating the Ethernet connection for both LAN1 and LAN2: • The green LED, labeled Link, illuminates when a valid connection to the network is established at a rate of 1000 Mbps and blinks when there is activity on the port. • The amber LED illuminates when you are communicating at a rate of 100 Mbps when using an Ethernet connection.
12 DSR2035/8035 Switch Installer/User Guide through the SETUP port on the back panel of the switch. See Chapter 6 for detailed instructions on how to use the SETUP port and web server to configure the switch. Setting up the DSView 3 software See the DSView Installer/User Guide that ships with your software, or refer to the DSView 3 Software Online Help.
Chapter 2: Installation 3. Click the Motion tab. 4. Set the Pointer speed slider to Slow (the leftmost tick mark). 5. Make sure the Snap to default checkbox is cleared. 13 6. Click OK to save your settings and to close the Mouse Properties dialog box. 7. Resynchronize the mouse in the software remote session window for the Avocent management software you are using: • • • If you are using DSView software version 2.x or earlier, click Mouse Align. If you are using DSView software version 3.
14 DSR2035/8035 Switch Installer/User Guide 7. Click OK to save your settings and to close the Mouse Properties dialog box. 8. Resynchronize the mouse in the software remote session window for the Avocent management software you are using: • • • If you are using DSView software version 2.x or earlier, click Mouse Align. If you are using DSView software version 3.0 or later, click Align Local Cursor. If you are using the AVWorks software, click Screen Refresh.
Chapter 2: Installation 15 3. Set the Acceleration slider to the center position. 4. (Optional) Select the desired Mouse buttons option and set the Threshold slider to the desired position. 5. Click OK to save your settings and to close the Control Center dialog box. 6. Resynchronize the mouse in the software remote session window for the Avocent management software you are using. • • • If you are using DSView software version 2.x or earlier, click Mouse Align.
16 DSR2035/8035 Switch Installer/User Guide 4. Click the Start Here icon to open the Start Here dialog box. 5. Click the Preferences icon to open the Control Center dialog box. 6. Click the Peripherals icon to open the Peripherals dialog box. 7. Click the Mouse icon to open the Mouse dialog box. 8. Set the Acceleration slider to the middle position. 9. (Optional) Select the desired Mouse buttons option and set the Threshold slider to the desired position. 10.
Chapter 2: Installation 17 UNIX To adjust the mouse speed and pointer settings for Sun Solaris v9 drivers: NOTE: To use a Sun Solaris driver with the DSView software and DSR switch, you must have the following versions of DSView software on your host system and DSR switch firmware: • DSView software version 2.x and earlier - DS Management Software suite version 1.0.9.202 or later • DSR switch with DSView software version 2.x and earlier - Firmware version 1.0.0.106 to 2.
18 DSR2035/8035 Switch Installer/User Guide To adjust the mouse speed and pointer settings for Sun Solaris v10 drivers: NOTE: To use a Sun Solaris driver with the DSView software and DSR switch, you must have the following versions of DSView software on your host system and DSR switch firmware: • DSView software version 2.x and earlier - DS Management Software suite version 1.0.9.202 or later • DSR switch with DSView software version 2.x and earlier - Firmware version 1.0.0.106 to 2.
Chapter 2: Installation 19 Novell NetWare To adjust the mouse speed and pointer settings for NetWare v5 and v6 drivers: Novell NetWare versions 5 and 6 are not delivered with a method for changing the mouse acceleration. An NLM (NetWare Loadable Module) jointly developed by Avocent and Novell is available from the Avocent web site which may be used to properly align the mouse. 1. In a web browser, enter http://www.avocent.com to visit the Avocent web site home page. 2.
20 DSR2035/8035 Switch Installer/User Guide Apple Mac OS To adjust the mouse speed and pointer settings for Versions 10.3 and later (using default drivers): NOTE: Apple Mac OS Versions 10.3 and later have no option to disable mouse acceleration with the provided drivers. The instructions below only slow down mouse acceleration rather than disabling it. However, if you are running a later version of the DSView management software, you can activate Single Cursor Mode to make the mouse pointer “invisible.
21 CHA PTER 3 Local Port Operation Controlling Your System at the Local Port The DSR2035/8035 switch includes a local port on the back. This port enables you to connect a keyboard, monitor and mouse to the switch for direct access. The DSR2035/8035 switch uses the OSCAR® graphical user interface, which has intuitive menus to configure your system and select target devices. Targets can be identified by customizable names.
22 DSR2035/8035 Switch Installer/User Guide Figure 3.1: OSCAR Interface Main Dialog Box Table 3.1: Main Dialog Box Functions Button Function VMedia Set virtual media options and make virtual media connections. This option is only available when a KVM session is in progress. Log Out Disconnect the KVM and user sessions. Clear Clear all offline DSRIQ modules. Disconnect Disconnect the KVM session. Setup Access the Setup dialog box and configure the OSCAR interface.
Chapter 3: Local Port Operation 23 Viewing the status of your DSR2035/8035 switching system The status of target devices in your system is indicated in the far right columns of the Main dialog box. The following table describes the status symbols. Table 3.2: OSCAR Interface Status Symbols Symbol Description (green circle) Server connected, powered up and the DSRIQ module is online. Connected target device is powered down or is not operating properly and the DSRIQ module is offline.
24 DSR2035/8035 Switch Installer/User Guide To select the previous target device: Press Print Screen and then Backspace. This key combination toggles you between the previous and current connections. To disconnect from a target device: Press Print Screen and then Alt+0 (zero). This leaves the user in a free state, with no target device selected. The status flag on your desktop displays Free. Soft switching Soft switching is the ability to switch target devices using a hotkey sequence.
Chapter 3: Local Port Operation 25 Navigating the OSCAR Interface This table describes how to navigate the OSCAR interface using the keyboard and mouse. Table 3.3: OSCAR Interface Navigation Basics Keystroke Function Print Screen Opens the OSCAR interface. Press Print Screen twice to send the Print Screen keystroke to the currently selected DSRIQ module. F1 Opens the Help screen for the current dialog box. Escape Closes the current dialog box without saving changes and returns to the previous one.
26 DSR2035/8035 Switch Installer/User Guide Table 3.3: OSCAR Interface Navigation Basics (Continued) Keystroke Function Shift-Del Deletes from the current selection to the end of the list when editing a Scan list. Numbers Type from the keyboard or keypad. Caps Lock Disabled. Use the Shift key to change case. Backspace Erases characters in a text box. Configuring OSCAR Interface Menus You can configure your DSR2035/8035 switching system from the Setup dialog box within the OSCAR interface.
Chapter 3: Local Port Operation 27 Figure 3.2: OSCAR Interface Setup Dialog Box Assigning target device names Use the Names dialog box to identify target devices by name rather than by port number. The Names list is always sorted by port order. You can toggle between displaying the name or the EID number of each DSRIQ module, so even if you move the target device to another port, the name and configuration will be recognized by the switch.
28 DSR2035/8035 Switch Installer/User Guide Figure 3.3: OSCAR Interface Names Dialog Box NOTE: If new DSRIQ modules are discovered by the DSR2035/8035 switch, the on-screen list will be automatically updated. The mouse cursor will change into an hourglass during the update. No mouse or keyboard input will be accepted until the list update is complete. To assign names to target devices: 1.
Chapter 3: Local Port Operation 29 Figure 3.4: OSCAR Interface Name Modify Dialog Box 2. Type a name in the New Name box. Names of target devices may contain all printable characters. 3. Click OK to transfer the new name to the Names dialog box. Your selection is not saved until you click OK in the Names dialog box. 4. Repeat steps 1-3 for each target device in the system. 5. Click OK in the Names dialog box to save your changes.
30 DSR2035/8035 Switch Installer/User Guide Figure 3.5: OSCAR Interface Devices Dialog Box When the DSR2035/8035 switch discovers a cascade switch, the numbering format changes from a DSR port only to [DSR port]-[switch port] to accommodate each target device under that switch. For example, if a switch is connected to DSR port 6, each target device connected to it would be numbered sequentially.
Chapter 3: Local Port Operation 31 To assign a device type: 1. In the Devices dialog box, select the desired port number. 2. Click Modify to open the Device Modify dialog box. Figure 3.6: OSCAR Interface Device Modify Dialog Box 3. Choose the number of ports supported by your switch and click OK. 4. Repeat steps 1-3 for each port requiring a device type to be assigned. 5. Click OK in the Devices dialog box to save settings.
32 DSR2035/8035 Switch Installer/User Guide Figure 3.7: OSCAR Interface Menu Dialog Box To choose the display order of target devices: 1. Select Name to display target devices alphabetically by name. -orSelect EID to display target devices numerically by EID number. -orSelect Port to display target devices numerically by port number. 2. Click OK. Depending on the display method selected, the corresponding button will be depressed in the Main dialog box.
Chapter 3: Local Port Operation 33 Controlling the status flag The status flag displays on your desktop and shows the name or EID number of the selected target device or the status of the selected port. Use the Flag dialog box to configure the flag to display by target device name or EID number, or to change the flag color, opacity, display time and location on the desktop. Table 3.5 desctibes each status flag. Table 3.
34 DSR2035/8035 Switch Installer/User Guide To determine how the status flag is displayed: 1. Select Name or EID to determine what information will be displayed. 2. Select Displayed to show the flag all the time or select Timed to display the flag for only five seconds after switching. 3. Select a flag color under Display Color.
Chapter 3: Local Port Operation 35 Figure 3.10: OSCAR Interface Broadcast Dialog Box NOTE: Broadcasting Keystrokes - The keyboard state must be identical for all target devices receiving a broadcast to interpret keystrokes identically. Specifically, the Caps Lock and Num Lock modes must be the same on all keyboards. While the switch attempts to send keystrokes to the selected target devices simultaneously, some target devices may inhibit and thereby delay the transmission.
36 DSR2035/8035 Switch Installer/User Guide To turn Broadcasting off: From the Commands dialog box, clear the Broadcast Enable checkbox. Using Scan mode In Scan mode, the DSR2035/8035 switch automatically scans from port to port (target device to target device). You can scan up to eight target devices, specifying which ones to scan and the number of seconds that each will display. The scanning order is determined by placement of the target device in the list. The list is always shown in scanning order.
Chapter 3: Local Port Operation 4. 37 Type the first few characters of a target device name or port number to scan. The first matching target device will appear in the line. -orPress the following keyboard commands in the Name, Port or Time column to move through the list of target devices available to scan. a. b. c. d. Press Alt+Down Arrow to move the cursor down through the list of target devices. Press Alt+Up Arrow to move the cursor up through the list of target devices.
38 DSR2035/8035 Switch Installer/User Guide 3. Select Scan Enable in the Commands dialog box. 4. Click X to close the Commands dialog box. NOTE: Scanning will begin as soon as the Scan Enable button is selected. To cancel Scan mode: Select a target device if the OSCAR interface is open. -orMove the mouse or press any key on the keyboard if the OSCAR interface is not open. Scanning will stop at the currently selected target device. -orIf the OSCAR interface is not open, press Print Screen.
Chapter 3: Local Port Operation 39 To set the Screen Saver options: NOTE: The Screen Saver password is set within the DSView software. For more information, see the DSView Installer/User Guide. 1. Type the number of minutes for Inactivity Time (from 1-99) to delay activation of password protection and the screen saver feature. 2. For Mode, select Energy if your monitor is ENERGY STAR® compliant; otherwise select Screen.
40 DSR2035/8035 Switch Installer/User Guide The Keyboard dialog box enables you to send a different keyboard country code than the default US setting. The specified country code is sent to all target devices attached to the DSR2035/8035 switches when they are powered up or rebooted and the new code is stored in the DSRIQ module. NOTE: If a DSRIQ module is moved to a different target device, the keyboard country code will need to be reset.
Chapter 3: Local Port Operation 41 Setting virtual media options You can determine the behavior of the DSR2035/8035 switch during a virtual media session using the options provided in the Virtual Media dialog box. Table 3.6 outlines the options that can be set for virtual media sessions. Table 3.
42 DSR2035/8035 Switch Installer/User Guide Figure 3.15: OSCAR Interface Virtual Media Dialog Box 3. Click to enable or disable each of the options. For information about individual settings, see Table 3.6 on page 41. 4. Click OK to accept the options you have selected and return to the Setup dialog box.
Chapter 3: Local Port Operation 43 To access the OSCAR interface Commands dialog box: 1. If the OSCAR interface is not open, press Print Screen to open the Main dialog box. 2. Click Commands to open the Commands dialog box as shown in Figure 3.16. Figure 3.16: OSCAR Interface Commands Dialog Box Viewing and disconnecting user connections You can view and disconnect users through the User Status dialog box.
44 DSR2035/8035 Switch Installer/User Guide Figure 3.17: OSCAR Interface User Status Dialog Box To disconnect a user: 1. If the OSCAR interface is not open, press Print Screen to open the Main dialog box. 2. Click Commands - User Status to open the User Status dialog box shown in Figure 3.17. 3. Click the letter corresponding to the user to disconnect. The Disconnect dialog box will appear as shown in Figure 3.18. Figure 3.
Chapter 3: Local Port Operation 4. 45 Click OK to disconnect the user and return to the User Status dialog box. -orClick X or press Escape to exit the dialog box without disconnecting a user. NOTE: If the User Status list has changed since it was last displayed, the mouse cursor will turn into an hourglass as the list is automatically updated. No mouse or keyboard input will be accepted until the list update is complete.
46 DSR2035/8035 Switch Installer/User Guide Figure 3.19: OSCAR Interface Version Dialog Box 3. To view individual DSRIQ module version information, click DSRIQ to open the DSRIQ Selection dialog box shown in Figure 3.20. Figure 3.20: DSRIQ Selection Dialog Box 4. Select a DSRIQ module to view and click the Version button. The DSRIQ Version dialog box appears. An example is shown in Figure 3.21 on page 47. For more information on loading firmware, refer to Appendix A.
Chapter 3: Local Port Operation Figure 3.21: DSRIQ Version Dialog Box 5. Click X to close the DSRIQ Version dialog box.
48 DSR2035/8035 Switch Installer/User Guide
49 CHA PTER 4 Web Server Operations Overview of the DSR2035/8035 Web Server In addition to the OSCAR on-screen interface, the DSR2035/8035 switch provides a built in web server to handle all basic KVM switching needs. For enhanced functionality and control of multiple devices, users can upgrade to the DSView 3 software package. The DSR web server provides secure “point-and-click” web browser-based access to control any device attached to your DSR2035/8035 switch.
50 DSR2035/8035 Switch Installer/User Guide About the DSR Explorer Window When a user has been logged in and authenticated, the Avocent DSR Explorer window appears. From the DSR Explorer window, users may view, access and manage their DSR2035/8035 switch. The window may also be used to specify system settings and change profile settings. Figure 4.1 shows the DSView Explorer window areas for the DSR2035/8035 switch. A B C Figure 4.1: Avocent DSR Explorer Window Table 4.
Chapter 4: Web Server Operations 51 Table 4.1: DSR Explorer Window Area Descriptions Letter Description A Top option bar - Use the top option bar to bookmark a DSR web server window, refresh the display of a DSR web server window, print a web page, log out of a software session or access the Avocent Technical Support help page. The name of the logged in user appears on the left side of the top option bar.
52 DSR2035/8035 Switch Installer/User Guide Using the top option bar Bookmarking a window (Internet Explorer only) The DSR Explorer window contains a bookmark icon and text in the top option bar. Bookmarking a window will add a link to the window in the Favorites drop-down menu. You may select the link at any time to quickly access the bookmarked window.
Chapter 4: Web Server Operations 53 Launching a KVM session To launch a KVM session from the DSR Explorer: 1. From the DSR Explorer, select Target Devices in the side navigation bar. A list of available devices will appear. 2. Click the KVM session link to the right of the target device that you wish to access. The Video Viewer will launch. For more information on the Video Viewer, see Chapter 5.
54 DSR2035/8035 Switch Installer/User Guide DSRIQ modules may also be force upgraded should the need arise. To force upgrade the DSRIQ module firmware using the DSR web server: 1. 2. From the side navigation bar, select Appliance - Appliance Settings - Ports - IQ modules. Select the IQ modules that you wish to upgrade and click the Upgrade button.
Chapter 4: Web Server Operations 4. 5. Select the preemption and access levels for the new user. Click the Save button to complete the process. To delete a user account (Administrator only): 1. 2. On the side menu bar, select Local Accounts. The current user list will be displayed. Click the box to the left of each account that you wish to delete, then click the delete button. To edit a user account (Administrator or active user only): 1. 2. 3. On the side menu bar, select local accounts.
56 DSR2035/8035 Switch Installer/User Guide Table 4.
Chapter 4: Web Server Operations 57 To power cycle a target device: 1. Select Appliance - Appliance Settings - Ports - SPC - Sockets from the DSR Explorer window. The SPC sockets window will appear. 2. Select the checkbox to the left of the device that you wish to cycle. 3. Click the Cycle button. To change the minimum on time, off time or wake up state: 1. 2. 3. 4. Select Appliance - Appliance Settings - Ports - SPC - Sockets from the DSR Explorer window.
58 DSR2035/8035 Switch Installer/User Guide
59 CHA PTER 5 The Video Viewer About the Video Viewer Window The Video Viewer is used to conduct a KVM session with the target devices attached to the DSR switch. When you connect to a device using the Video Viewer, the target device desktop appears in a separate window containing both the local and the target device cursor. The Video Viewer window supports either a 3- or 5-button mouse. The DSR web server software uses a Java-based program to display the Video Viewer window.
60 DSR2035/8035 Switch Installer/User Guide The Video Viewer client requires Java version 1.4.2_04 or later when opened from Internet Explorer, Mozilla, Netscape or Firefox browsers. The DSR web server automatically downloads and installs the Video Viewer the first time it is opened. NOTE: The DSR web server does not install the Java Resource Engine (JRE). The JRE is available from http:\\www.sun.com as a free download.
Chapter 5: The Video Viewer 61 Video Viewer Window Features Figure 5.1 shows the Video Viewer window areas, and descriptions follow in Table 5.1 on page 62. B C A H I Figure 5.
62 DSR2035/8035 Switch Installer/User Guide Table 5.1: Video Viewer Window Description Letter Description A Title Bar: Displays the name of the server being viewed. When in Full Screen mode, the title bar disappears and the server name appears between the menu and toolbar. B Thumbtack: Locks the display of the menu and toolbar so that it is visible at all times. C Menu and toolbar: Enables you to access many of the features in the Video Viewer window.
Chapter 5: The Video Viewer 63 Changing the toolbar You can choose the amount of elapsed time before the toolbar hides in the Video Viewer window when it is in show/hide state (that is, not locked in place by the thumbtack). To specify a toolbar hide time: 1. Select Tools - Session Options from the Video Viewer window menu. -orClick the Session Options button. The Session Options dialog box appears. 2. Click the Toolbar tab. 3.
64 DSR2035/8035 Switch Installer/User Guide Adjusting the view Using menus or Task buttons in the Video Viewer window, you can do the following: • Align the mouse cursors. • Refresh the screen. • Enable or disable Full Screen mode. When Full Screen mode is enabled, the image adjusts to fit the desktop up to a size of 1024 x 768.
Chapter 5: The Video Viewer 65 To enable or disable full screen mode: 1. To enable Full Screen mode, click the Maximize button. -orSelect View - Full Screen from the Video Viewer window menu. The desktop window disappears and only the accessed device desktop is visible. The screen resizes up to a maximum of 1024 x 768. If the desktop has a higher resolution, then a black background surrounds the full screen image. The floating toolbar appears. -or- 2.
66 DSR2035/8035 Switch Installer/User Guide Additional video adjustment Generally, the Video Viewer window automatic adjustment features optimizes the video for the best possible view. However, users can fine-tune the video with the help of Avocent Technical Support by selecting the Tools - Manual Video Adjust command in the Video Viewer window menu or clicking the Manual Video Adjust button. This displays the Manual Video Adjust dialog box. Video adjustment is a per target setting.
Chapter 5: The Video Viewer 67 Table 5.2: Manual Video Adjust Dialog Box Descriptions Letter Description Letter Description A Image Capture Width H Pixel Noise Threshold B Pixel Sampling/Fine Adjust I Automatic Video Adjustment C Image Capture Horizontal Position J Refresh Image D Image Capture Vertical Position K Adjustment bar E Contrast L Video Test Pattern F Brightness M Performance Monitor G Block Noise Threshold N Close button 2.
68 DSR2035/8035 Switch Installer/User Guide You can modify Noise Threshold and Priority Threshold values if you are using standard video compression. You can also modify Block Noise Threshold and Pixel Noise Threshold values. You can restore default threshold values by clicking Auto Adjust Video. Block noise threshold and pixel noise threshold The Block Noise Threshold and Pixel Noise Threshold values set the minimum color levels in terms of changed video blocks and pixels per thousand that are allowed.
Chapter 5: The Video Viewer 69 NOTE: If the device does not support the ability to disconnect and reconnect the mouse (almost all newer PCs do), then the mouse will become disabled and the device will have to be rebooted. Cursor Type The Video Viewer window offers five appearance choices for the local mouse cursor. You can also choose no cursor or the default cursor.
70 DSR2035/8035 Switch Installer/User Guide To select a key for exiting single cursor mode: 1. Select Tools - Session Options from the Video Viewer window menu. -orClick the Session Options button. The Session Options dialog box appears. 2. Click the Mouse tab. 3. Select a terminating keystroke from the drop-down menu in the Single Cursor mode area. 4. Click OK to save settings. When you enable Single Cursor mode, you can press the specified key to return to Regular Desktop mode.
Chapter 5: The Video Viewer 71 The Session Options dialog box appears. 2. Click the Mouse tab. 3. To use one of the preconfigured settings, check the appropriate radio button. -orTo set custom scaling: a. Click the Custom radio button to enable the X and Y fields. b. Type a mouse scaling value in the X and Y fields. For every mouse input, the mouse movements are multiplied by the respective X and Y scaling factors. Valid input range is 0.25-3.00.
72 DSR2035/8035 Switch Installer/User Guide NOTE: The Japanese keyboard ALT-Han/Zen keystroke combination is always sent to a remote server regardless of the screen mode or keyboard pass-through setting. To specify keyboard pass-through: 1. Select Tools - Session Options from the Video Viewer window menu. -orClick the Session Options button. The Session Options dialog box appears. 2. Click the General tab. 3. Select Pass-through all keystrokes in regular window mode. 4. Click OK to save setting.
Chapter 5: The Video Viewer To capture the Video Viewer window to your clipboard: Select File - Capture to Clipboard from the Video Viewer window menu. -orClick the Capture to Clipboard button. The image data is saved to the clipboard. Closing a Video Viewer Window Session To close a Video Viewer window session: Select File - Exit from the Video Viewer window.
74 DSR2035/8035 Switch Installer/User Guide
75 CHA PTER 6 Terminal Operations The Console Menu Each DSR2035/8035 switch may be configured at the appliance level through the Console menu interface accessed through the SETUP port on the back of the switch. All terminal commands are accessed through a terminal or PC running terminal emulation software. NOTE: This is NOT the recommended method for setting options for the DSR2035/8035 switch. The preferred method is to make all configuration settings in the DSView Server software.
76 DSR2035/8035 Switch Installer/User Guide Figure 6.1: Console Main Menu 2. Once the Console Main menu displays, type 1 and press Enter to access the Network Configuration menu shown in Figure 6.2. Figure 6.
Chapter 6: Terminal Operations 77 3. Type 1 and press Enter to set your network speed. When possible, you should set your connection manually without relying on the auto negotiate feature. After you press Enter, you will be returned to the Network Configuration menu. 4. Type 2 and press Enter to specify whether you are using a static or Dynamic Host Configuration Protocol (DHCP) address.
78 DSR2035/8035 Switch Installer/User Guide Local user accounts NOTE: When you use the options to add, edit or delete a user, a list of existing users will appear. You may enter N to display the next page of users in the database or enter P to go back to the previous page of users. To add a user to the DSR2035/8035 switch database: 1. Type 2 and press Enter to access the Security Configuration menu option. 2. Type 1 and press Enter to access the Local User Accounts menu option.
Chapter 6: Terminal Operations 79 Console password If this is enabled, access to the switch’s Console Main menu will require the user to log in. Reset certificates This menu option enables you to clear the certificate sent by the DSView software to the DSR2035/8035 switch. When a DSR2035/8035 switch is added to a server running DSView software, a certificate is downloaded from that server to the DSR2035/8035 switch automatically.
80 DSR2035/8035 Switch Installer/User Guide Restore factory defaults This menu option will restore all switch options to the default settings. Reset appliance This menu option allows you to execute a soft reset of the DSR2035/8035 switch. Exit This menu selection will return you to the ready prompt. If the Console menu interface password is enabled, you must exit the Console Main menu so that the next user will be prompted with the Username and Password login screen.
81 A P P EN D IC ES Appendices Appendix A: FLASH Upgrades The DSR2035/8035 switch FLASH upgrade feature allows you to update your appliance with the latest firmware available. This update can be performed using the DSView software or using a Trivial File Transfer Protocol (TFTP) server. After the FLASH memory is reprogrammed with the upgrade, the DSR2035/8035 switch performs a soft reset, which terminates all DSRIQ module sessions.
82 DSR2035/8035 Switch Installer/User Guide 8. Enter the name of the file that you downloaded from the Avocent web site. 9. Confirm the TFTP download by typing a y or yes and pressing Enter. 10. The DSR2035/8035 switch will begin the FLASH upgrade process. On-screen indicators will display the upgrade progress. When the upload is complete, the DSR2035/8035 switch will reset and upgrade the internal subsystems. 11. Once the upgrade is complete, the login screen will appear.
Appendices 83 Appendix B: Using DSView Software Over a Modem Connection An external modem may be attached to the DSR2035/8035 switch. This modem may be used to access the switch when an Ethernet connection is not available. A modem/PPP dial-up connection must be established before the remote operation is enabled. The dial-up connection options should be set to 115,200 bps, 8 bits, 1 stop bit, no parity and enabled hardware flow control.
84 DSR2035/8035 Switch Installer/User Guide Appendix C: Using DSRIQ-SRL Modules The DSRIQ-SRL module is a serial-to-VGA converter which permits VT100-capable devices to be viewed from the DSR2035/8035 switch local port or by using the DSView software. The actual serial data is not accessed, but is merely displayed. All serial data coming from the target device is displayed in a VT100 window, placed into a video buffer and sent to the DSR2035/8035 switch as though it came from a VGA target.
Appendices 85 • Enter Sends: This option enables you to specify the keys that are transmitted when Enter is pressed. Available options are (Enter), which moves the cursor to the left side of the screen, or (Enter-Linefeed), which moves the cursor to the left side of the screen and down one line. • Received: This option enables you to specify how the module translates a received Enter character. Available options are (Enter) or (Enter-Linefeed).
86 DSR2035/8035 Switch Installer/User Guide To configure a DSRIQ-SRL module: 1. Press Ctrl-F8. The Configuration Screen will appear. 2. Select a parameter to change. You can navigate the Configuration Screen using the Up Arrow and Down Arrow keys. 3. Modify the selected value using the Left Arrow and Right Arrow keys. 4. Repeat steps 2 and 3 to modify additional values. 5. Press Enter to save your changes and exit the Configuration Screen.
Appendices 87 To use History mode: 1. 2. Press Ctrl-F9. The mode will display as History. Press one of the following key combinations to perform the indicated action: • Home: Move to the top of the buffer. • End: Move to the bottom of the buffer. • Page Up: Move up one buffer page. • Page Down: Move down one buffer page. • Up Arrow: Move up one buffer line. • Down Arrow: Move down one buffer line. • Ctrl-F8: Enters Configuration mode. The Configuration screen will appear.
88 DSR2035/8035 Switch Installer/User Guide Appendix D: UTP Cabling This appendix discusses various aspects of connection media. The performance of a DSR2035/8035 switching system depends on high quality connections. Poor quality or poorly installed or maintained cabling can diminish DSR system performance. NOTE: This appendix is for information purposes only. Please consult with your local code officials and/or cabling consultants prior to any installation.
Appendices 89 Cabling installation, maintenance and safety tips The following is a list of important safety considerations that should be reviewed prior to installing or maintaining your cables: • Keep all CAT 5 runs to a maximum of 10 meters each. • Maintain the twists of the pairs all the way to the point of termination, or no more that one-half inch untwisted. Do not skin off more than one inch of jacket while terminating.
90 DSR2035/8035 Switch Installer/User Guide Appendix E: Technical Specifications Table E.1 lists the technical specifications for the DSR2035/8035 switch. Table E.
Appendices 91 Table E.1: DSR2035/8035 Switch Product Specifications (Continued) USB Device Port Number 5 Type USB 2.0 Height x Width x Depth 1.72 x 17.00 x 14.08 in; 1U form factor (4.37 x 43.18 x 35.75 cm) Weight 10 lbs (4.5 kg) without cables Dimensions Power Supply AC-input Power 40 W maximum AC-input Range 100 - 240 VAC AC-input Current Rating 1.
92 DSR2035/8035 Switch Installer/User Guide Appendix F: Sun Advanced Key Emulation Certain keys on a standard Type 5 (US) Sun keyboard can be emulated by key press sequences on a PS/2 keyboard. To enable Sun Advanced Key Emulation mode and use these keys, press and hold Ctrl+Shift+Alt and then press the Scroll Lock key. The Scroll Lock LED blinks. Use the indicated keys in Table F.1 as you would use the advanced keys on a Sun keyboard. Table F.
Appendices 93 For example: For Stop + A, press and hold Ctrl+Shift+Alt and press Scroll Lock, then F1 + A. These key combinations will work with the DSRIQ-USB module (if your Sun system comes with a USB port) as well as the Sun DSRIQ-VSN and DSRIQ-WSN modules. With the exception of F12, these key combinations are not recognized by Microsoft Windows. Using F12 performs a Windows key press.
94 DSR2035/8035 Switch Installer/User Guide Appendix G: Technical Support Our Technical Support staff is ready to assist you with any installation or operating issues you encounter with your Avocent product. If an issue should develop, follow the steps below for the fastest possible service. To resolve an issue: 1. Check the pertinent section of the manual to see if the issue can be resolved by following the procedures outlined. 2. Check our web site at www.avocent.
95 INDEX Index Numerics Broadcast 1000BaseT Ethernet 1, 5, 90 dialog box 35 100BaseT Ethernet 5, 90 Enable 42 10BaseT Ethernet 5, 90 OSCAR interface 26 C A cascade switch 26, 30 access direct 21 CAT 5 patch cable 2, 8, 9, 10, 88, 89, 90 DSRIQ module 23 Changing the Display Behavior 31 OSCAR interface Commands Broadcast 35 Broadcast dialog box 34 Broadcast Enable 35, 42 Commands dialog box 43 dialog box 37, 43 Devices dialog box 29 Display Versions 42, 45 Flag dialog box 33 Reset PS
96 DSR2035/8035 Installer/User Guide DSRIQ modules 23 flag 33 DSView software 2, 5, 6, 8, 10, 38, 39, 75, 77, 79, 81, 83, 84 target device 24 database 79 user 44 illustrated 3 user connections 43 Screen Saver password 39 users 42, 43, 44, 45 Secure mode 77 Display Versions 42 security 79 DSR switch 1 system 77 comes with 8 Features 1 Installation 5 Network Configuration 3 port 30 Product Specifications 90 DSR switch database E Enable Debug Messages 79 Escape 25, 29, 35, 45 Example DSR Switc
Index J Names dialog box 26, 28 Japanese Notice ii Japanese Sun USB Keyboards 93 K keyboard dialog box 40 OSCAR interface 26 network speed 77 null modem cable 10, 81 O OSCAR interface Alt 25 Korean Sun USB Keyboards 93 Broadcast dialog box 34, 35 KVM 5 change the display order 31 cable volume 2 Commands dialog box 37, 43 illustrated 7 Commands menu 43 switch 1 Device Modify dialog box 31 KVM session.
98 DSR2035/8035 Installer/User Guide P To connect a DSRIQ module to a server 10 To connect and power up your DSR switch 9 Point-to-Point Protocol 5 To create a DSRIQ-SRL module macro 86 Position Flag 34 To determine how the Status flag is displayed 34 PPP 5 To disconnect a user 44 Print Screen 25 To disconnect from a target device 24 OSCAR interface 26 To display version information 45 procedure To exit screen saver mode and log in to the local port 39 To access the OSCAR interface Broadcast
Index remove a user from the DSR switch database 78 rename a user in the DSR switch database 78 Requirements U upgrade the DSR switch firmware 81 User Connections Video Viewer 59 Reset Appliance 80 Reset Certificates 79 Reset PS/2 42 Viewing and Disconnecting 43 User Status 42 User Status Dialog Box 44 Using Scan Mode 36 Restore Factory Defaults 80 V S Verifying the Connections 11 Safety Precautions 4 Version Dialog Box 46 Scan Video Viewer dialog box 36, 37 Enable 38, 42 mode 36, 37 OSCAR inte
100 DSR2035/8035 Installer/User Guide setting options 41
Commutateur DSR® Guide d’installation et d’utilisation Pour les modèles DSR2035 et DSR8035 Avocent, le logo Avocent, The Power of Being There, DSR, DSView, Dambrackas Video Compression, AVWorks et OSCAR sont des marques de commerce ou des marques déposées d’Avocent Corporation ou de ses filiales. Toutes les autres marques sont la propriété exclusive de leurs détenteurs respectifs. © 2005 Avocent Corporation. Tous droits réservés. 590-535-616A.
Notification pour les États-Unis Avertissement : Les modifications apportées à ce produit sans l’accord exprès de la partie responsable de la conformité peuvent annuler l’autorisation dont vous bénéficiez pour utiliser cet équipement. Nota : L’équipement a été testé et déclaré conforme aux limites définies pour les appareils numériques de classe A, suivant l’article 15 du règlement de la FCC.
iii TA BLE DE S M ATI ÈR ES Liste des Figures ........................................................................................................... vii Liste des Tableaux ......................................................................................................... ix Chapitre 1 : Présentation du produit ............................................................................. 1 Caractéristiques et avantages .............................................................................
iv Guide d’installation et d’utilisation du commutateur DSR2035/8035 Chapitre 3 : Fonctionnement de la voie locale ........................................................... 23 Contrôle du système par la voie locale .......................................................................................... 23 Visualisation et sélection des voies et des serveurs ................................................................ 23 Visualisation de l’état du système de commutation DSR2035/8035 ...............
Table des Matières Utilisation de la voie terminal ...................................................................................... 77 Menu de la console ......................................................................................................................... 77 Configuration réseau ...................................................................................................................... 77 Autres options du menu principal de la console ....................................
vi Guide d’installation et d’utilisation du commutateur DSR2035/8035
vii L I S T E D E S F IG U R E S Figure 1.1 : Exemple de configuration du commutateur DSR2035/8035 ........................................ 3 Figure 2.1 : Configuration de base du commutateur DSR2035/8035 (Commutateur DSR8035 illustré) ................................................................................. 7 Figure 3.1 : Boîte de dialogue Principal de l’interface OSCAR .................................................... 24 Figure 3.2 : Boîte de dialogue Configuration de l’interface OSCAR ......
viii Guide d’installation et d’utilisation du commutateur DSR2035/8035
ix LISTE DES T ABLEAUX Tableau 3.1 : Fonctions de la boîte de dialogue Principal ............................................................ 24 Tableau 3.2 : Symboles d’état utilisés dans l’interface OSCAR ..................................................... 25 Tableau 3.3 : Concepts de base de la navigation dans OSCAR ..................................................... 27 Tableau 3.4 : Fonctions de configuration de l’interface OSCAR ................................................... 28 Tableau 3.
x Guide d’installation et d’utilisation du commutateur DSR2035/8035
1 CHAPITRE 1 Présentation du produit Caractéristiques et avantages Les commutateurs Avocent DSR® allient les technologies numérique et analogique afin de permettre un contrôle flexible et centralisé des serveurs de centres de données ainsi que des équipements Virtual Media, et de faciliter le fonctionnement, l’activation et la maintenance des succursales éloignées ne disposant pas d’opérateurs formés.
2 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Réduction de l’encombrement dû aux câbles La densité des serveurs augmente sans cesse et l’encombrement des câbles reste l’un des principaux problèmes des administrateurs de réseau. Le commutateur DSR2035/8035 réduit considérablement le volume de câbles KVM dans le rack grâce au module DSRIQ innovant et au câblage UTP (à paires torsadées non blindées) CAT 5 unique.
Chapitre 1 : Présentation du produit 3 Accès simple à tout équipement cible Lorsque vous accédez au logiciel DSView Server, une liste de tous les équipements que vous êtes autorisé à visualiser et à gérer s’affiche. Lorsque vous sélectionnez un équipement cible dans la liste, son bureau s’affiche dans le visualiseur vidéo.
4 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Mesures de sécurité Afin d’éviter d’éventuels problèmes de vidéo ou de clavier lors de l’utilisation des produits Avocent, prenez les précautions suivantes : • Si le bâtiment est alimenté en courant alternatif triphasé, assurez-vous que l’ordinateur et le moniteur sont sur la même phase. Pour des résultats optimaux, ils doivent se trouver sur le même circuit.
5 CHAPITRE Installation 2 Connectivité du commutateur DSR Le système de commutateur DSR2035/8035 nécessite une connexion à un serveur doté du logiciel DSView 3. Le logiciel DSView 3 vous permet de visualiser et de contrôler les équipements cibles (un par un) reliés au système de commutation DSR2035/8035. Pour de plus amples informations sur le logiciel DSView 3, reportez-vous au guide d’installation et d’utilisation du DSView.
6 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Installation du commutateur DSR Procédez comme suit pour configurer et installer le commutateur DSR2035/8035 : • Retirez le commutateur DSR2035/8035 de l’emballage et assurez-vous que tous les éléments sont présents et en bon état. Consultez la section Démarrage de ce chapitre.
Chapitre 2 : Installation Modem Utilisateur analogique Réseau téléphonique Virtual Media externe Réseau Utilisateur numérique Commutateur DSR8035 Alimentation Cordon Connexion Voies 1-32 Connexions voie SPC Dispositif de contrôle de l’alimentation SPC Dispositif de contrôle de l’alimentation SPC Connexions USB locales Serveurs 1 à 32 * Pour ouvrir une session Virtual Media à partir d’un serveur, celui-ci doit tout d’abord être connecté au commutateur à l’aide d’un module DSRIQ compatible Virtu
8 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Configuration de votre réseau Le système de commutation DSR2035/8035 utilise des adresses IP pour identifier de manière unique le commutateur et chaque équipement cible. Il prend en charge le protocole DHCP (Dynamic Host Configuration Protocol) ainsi que l’adressage IP statique.
Chapitre 2 : Installation 9 Connexion du commutateur DSR2035/8035 NOTA : Le commutateur DSR2035/8035 peut être monté en rack en configuration 1 U. Le commutateur DSR2035/8035 n’est pas compatible avec une configuration 0 U. Connexion et mise sous tension du commutateur DSR2035/8035 : 1. Mettez hors tension l’équipement (ou les équipements) faisant partie de votre système de commutation DSR2035/8035.
10 Guide d’installation et d’utilisation du commutateur DSR2035/8035 8.
Chapitre 2 : Installation 11 Vérification des connexions Commutateur DSR2035/8035 Le panneau avant du commutateur DSR2035/8035 est doté de deux voyants se rapportant aux connexions Ethernet pour les LAN1 et LAN2 : • Le voyant vert, portant la mention Link, s’allume lorsque la connexion au réseau est correctement établie à une vitesse de 1 000 Mbits/s et clignote lorsque la voie est active.
12 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Configuration du serveur Web intégré Vous pouvez accéder au commutateur DSR2035/8035 par l’intermédiaire d’un serveur Web intégré capable de gérer la plupart des tâches de commutation de routine. Avant d’accéder au commutateur via le serveur Web, veuillez spécifier une adresse IP à l’aide de la voie SETUP située sur le panneau arrière du commutateur.
Chapitre 2 : Installation 13 Microsoft Windows NOTA : Avocent recommande fortement que tous les systèmes Microsoft® Windows reliés au commutateur numérique DS1800, aux commutateurs DSR, aux équipements d’administration de consoles CCM et aux équipements d’accès à distance SwitchView IP soient dotés du pilote de souris PS/2 Windows. Réglage de la vitesse de la souris et des paramètres du pointeur sous NT 4.0 (à l’aide des pilotes par défaut) : 1.
14 Guide d’installation et d’utilisation du commutateur DSR2035/8035 8. Resynchronisez la souris dans la fenêtre du visualiseur de session vidéo en fonction du logiciel d’administration Avocent que vous utilisez : • • • Si vous utilisez une version 2.x ou antérieure du logiciel DSView, cliquez sur Mouse Align. Si vous utilisez la version 3.0 ou ultérieure du logiciel DSView, cliquez sur Align Local Cursor. Si vous utilisez le logiciel AVWorks, cliquez sur Screen Refresh.
Chapitre 2 : Installation 15 4. Déplacez la barre de défilement de la vitesse du pointeur sur le point médian (cinquième graduation en partant de la gauche). 5. Désactivez la case Améliorer la précision du pointeur. 6. Assurez-vous que les cases « Position par défaut » et de visibilité ne sont pas activées. 7. Cliquez sur l’onglet Molette. 8. Désactivez la case Activer le défilement accéléré. 9.
16 Guide d’installation et d’utilisation du commutateur DSR2035/8035 6. Resynchronisez la souris dans la fenêtre du visualiseur de session vidéo en fonction du logiciel d’administration Avocent que vous utilisez. • • • Si vous utilisez une version 2.x ou antérieure du logiciel DSView, cliquez sur Mouse Align. Si vous utilisez la version 3.0 ou ultérieure du logiciel DSView, cliquez sur Align Local Cursor. Si vous utilisez le logiciel AVWorks, cliquez sur Screen Refresh.
Chapitre 2 : Installation 17 3. Passez à l’étape 8 à la page 17. 4. Cliquez sur l’icône Démarrer ici pour ouvrir la boîte de dialogue Démarrer ici. 5. Cliquez sur l’icône Préférences pour ouvrir la boîte de dialogue Centre de commandes. 6. Cliquez sur l’icône Périphériques pour ouvrir la boîte de dialogue Périphériques. 7. Cliquez sur l’icône Souris pour ouvrir la boîte de dialogue Souris. 8. Centrez la barre de défilement Accélération. 9.
18 Guide d’installation et d’utilisation du commutateur DSR2035/8035 11. Resynchronisez la souris dans la fenêtre du visualiseur de session vidéo en fonction du logiciel d’administration Avocent que vous utilisez : • • • Si vous utilisez une version 2.x ou antérieure du logiciel DSView, cliquez sur Mouse Align. Si vous utilisez la version 3.0 ou ultérieure du logiciel DSView, cliquez sur Align Local Cursor. Si vous utilisez le logiciel AVWorks, cliquez sur Screen Refresh.
Chapitre 2 : Installation 8. 9. 19 Pour régler la mise à l’échelle de la souris sur la position normale, réalisez les actions suivantes : a. Dans le menu Video Viewer (Visualiseur vidéo), sélectionnez Tools - Session Options (Outils - Options de session) pour ouvrir la boîte de dialogue Session Options. b. Cliquez sur l’onglet Mouse (Souris). c. Dans la zone Mouse Scaling (Mise à l’échelle de la souris), sélectionnez le bouton radio Default (Paramètres par défaut). d.
20 Guide d’installation et d’utilisation du commutateur DSR2035/8035 7. 8. Pour régler la mise à l’échelle de la souris sur la position normale, réalisez les actions suivantes : a. Dans le menu Video Viewer, sélectionnez Tools - Session Options pour ouvrir la boîte de dialogue Session Options. b. Cliquez sur l’onglet Mouse. c. Dans la zone Mise à l’échelle de la souris, sélectionnez le paramètres Default. d.
Chapitre 2 : Installation 21 Réglage de la vitesse de la souris et des paramètres du pointeur pour les pilotes NetWare v6.5 : 1. Tout en exécutant le logiciel d’administration DSView, cliquez sur le bouton Novell de la barre d’outils située sur la partie inférieure de la fenêtre de session du visualiseur vidéo Avocent. 2. Dans le menu contextuel, sélectionnez Paramètres - Environnement GUI. 3. Sélectionnez l’onglet Entrée dans la fenêtre Environnement GUI. 4.
22 Guide d’installation et d’utilisation du commutateur DSR2035/8035 8. Resynchronisez la souris dans la fenêtre du visualiseur de session vidéo en fonction du logiciel d’administration Avocent que vous utilisez. • • • Si vous utilisez une version 2.x ou antérieure du logiciel DSView, cliquez sur Mouse Align. Si vous utilisez la version 3.0 ou ultérieure du logiciel DSView, cliquez sur Align Local Cursor. Si vous utilisez le logiciel AVWorks, cliquez sur Screen Refresh.
23 CHAPITRE 3 Fonctionnement de la voie locale Contrôle du système par la voie locale Le commutateur DSR2035/8035 est équipé d’une voie locale à l’arrière. Cette voie vous permet de relier un clavier, un moniteur et une souris au commutateur pour un accès direct. Le commutateur DSR2035/8035 fonctionne avec OSCAR®, une interface graphique utilisateur intuitive qui vous permet de configurer votre système et de sélectionner les équipements cibles. Les noms des cibles sont personnalisables.
24 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Figure 3.1 : Boîte de dialogue Principal de l’interface OSCAR Tableau 3.1 : Fonctions de la boîte de dialogue Principal Bouton Fonction VMedia Configure les options et effectue les connexions Virtual Media. Cette option est disponible uniquement lorsque la session KVM est activée. Désactivation Déconnecte les sessions KVM et utilisateur. Suppression Supprime tous les modules DSRIQ hors ligne.
Chapitre 3 : Fonctionnement de la voie locale 25 Visualisation de l’état du système de commutation DSR2035/8035 L’état des équipements cibles du système est affiché dans les colonnes de droite de la boîte de dialogue Principal. Le tableau suivant présente les différents symboles d’état. Tableau 3.2 : Symboles d’état utilisés dans l’interface OSCAR Symbole Description (cercle vert) Serveur connecté et sous tension, module DSRIQ en ligne.
26 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Sélection de l’équipement cible précédent : Appuyez sur Impr écran, puis sur Retour arrière. Cette combinaison de touches permet de basculer entre la connexion actuelle et la connexion précédente. Déconnexion d’un équipement cible : Appuyez sur Impr écran, puis sur Alt+0 (zéro). Ceci place l’utilisateur en état libre, sans aucun équipement cible sélectionné. L’indicateur d’état du bureau affiche le message Libre.
Chapitre 3 : Fonctionnement de la voie locale 27 Navigation dans l’interface OSCAR Le tableau suivant décrit comment utiliser le clavier et la souris pour naviguer dans l’interface OSCAR. Tableau 3.3 : Concepts de base de la navigation dans OSCAR Touche Fonction Impr écran Ouvre l’interface OSCAR. Appuyez deux fois sur Impr écran pour envoyer la commande Impr écran au module DSRIQ actuellement sélectionné. F1 Permet d’afficher l’aide relative à la boîte de dialogue active.
28 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Tableau 3.3 : Concepts de base de la navigation dans OSCAR (suite) Touche Fonction Début/Fin Permet de positionner le curseur au début ou à la fin d’une liste. Retour arrière Efface les caractères d’une zone de texte. Suppr Supprime la sélection actuelle de la liste de balayage ou efface les caractères d’une zone de texte.
Chapitre 3 : Fonctionnement de la voie locale 29 Accès à la boîte de dialogue Configuration de l’interface OSCAR : 1. Appuyez sur Impr écran pour lancer l’interface OSCAR. La boîte de dialogue Principal s’affiche. 2. Cliquez sur Config. pour ouvrir la boîte de dialogue Configuration. Figure 3.
30 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Figure 3.3 : Boîte de dialogue Noms de l’interface OSCAR NOTA : La liste affichée à l’écran est automatiquement mise à jour lorsque le commutateur DSR2035/8035 détecte de nouveaux modules DSRIQ. Le curseur de la souris prend la forme d’un sablier pendant l’actualisation de la liste. Aucune opération souris ou clavier n’est acceptée tant que la mise à jour de la liste n’est pas terminée. Attribution d’un nom à l’équipement cible : 1.
Chapitre 3 : Fonctionnement de la voie locale 31 Figure 3.4 : Boite de dialogue Modifier nom de l’interface OSCAR 2. Saisissez un nom dans le champ Nouveau nom. Les noms des équipements cibles peuvent contenir tout caractère imprimable. 3. Cliquez sur OK pour transférer le nouveau nom vers la boîte de dialogue Noms. Votre sélection n’est pas sauvegardée tant que vous n’avez pas cliqué sur OK dans la boîte de dialogue Noms. 4. Répétez les étapes 1 à 3 pour chacun des équipements cibles du système.
32 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Figure 3.5 : Boîte de dialogue Équipements de l’interface OSCAR Lorsque le DSR2035/8035 détecte un commutateur en cascade, le format de numérotation change : du format voie DSR seule, il passe au format [voie DSR]-[voie du commutateur] afin de prendre en compte tous les équipements cibles reliés à ce commutateur.
Chapitre 3 : Fonctionnement de la voie locale 33 Attribution d’un type d’équipement : 1. Dans la boîte de dialogue Équipements, sélectionnez le nombre de voies voulu. 2. Cliquez sur le bouton Modifier pour ouvrir la boîte de dialogue Modif. équip. Figure 3.6 : Boîte de dialogue Modif. équip. de l’interface OSCAR 3. Choisissez le nombre de voies prises en charge par votre commutateur et cliquez sur OK. 4.
34 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Figure 3.7 : Boîte de dialogue Menu de l’interface OSCAR Détermination de l’ordre d’affichage des équipements cibles : 1. Sélectionnez Nom pour afficher les équipements cibles dans l’ordre alphabétique (par nom). -ouSélectionnez EID pour afficher les équipements dans l’ordre numérique (par numéro EID). -ouSélectionnez Voie pour afficher les équipements cibles dans l’ordre numérique (par numéro de voie). 2. Cliquez sur OK.
Chapitre 3 : Fonctionnement de la voie locale 35 Contrôle de l’indicateur d’état L’indicateur d’état s’affiche sur le bureau et indique le nom ou le numéro d’EID de l’équipement cible sélectionné ou l’état de la voie sélectionnée. La boîte de dialogue Indicateur permet de configurer l’indicateur de manière qu’il affiche le nom ou le numéro d’EID de l’équipement cible ; elle permet également de modifier la couleur, l’opacité, le temps d’affichage et l’emplacement sur le bureau de l’indicateur.
36 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Affichage de l’indicateur d’état : 1. Sélectionnez Nom ou EID pour déterminer l’information à afficher. 2. Sélectionnez Affiché pour que l’indicateur soit toujours affiché ou Temporisé pour que l’affichage ne dure que cinq secondes après une commutation. 3. Sélectionnez une couleur dans la zone Couleur d’affichage. Les couleurs d’indicateur suivantes sont disponibles : • • • • Ind. 1 : indicateur gris avec texte en noir Ind.
Chapitre 3 : Fonctionnement de la voie locale 37 Accès à la boîte de dialogue Diffusion de l’interface OSCAR : 1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran pour ouvrir la boîte de dialogue Principal. 2. Cliquez sur Config. - Diffusion pour ouvrir la boîte de dialogue Diffusion, comme indiqué à la Figure 3.10 à la page 37. Figure 3.
38 Guide d’installation et d’utilisation du commutateur DSR2035/8035 2. Cliquez sur OK pour enregistrer les paramètres et revenir à la boîte de dialogue Configuration. Cliquez sur X ou appuyez sur Echap pour revenir à la boîte de dialogue Principal. 3. Cliquez sur Commandes pour ouvrir la boîte de dialogue Commandes. 4. Cochez la case Activer la diffusion pour activer la diffusion. 5. À partir de la console utilisateur, saisissez les données et effectuez les mouvements de souris à diffuser.
Chapitre 3 : Fonctionnement de la voie locale 39 3. Déterminez l’endroit de la liste où vous souhaitez ajouter l’équipement cible. Si la liste de balayage ne contient aucun équipement cible, le curseur s’affiche sur une ligne vierge en haut de la liste. -ouPour ajouter un serveur à la fin de la liste, placez votre curseur sur la dernière entrée et appuyez sur la flèche Bas.
40 Guide d’installation et d’utilisation du commutateur DSR2035/8035 2. Cliquez sur le bouton Commandes pour ouvrir la boîte de dialogue Commandes, comme indiqué à la Figure 3.12. Figure 3.12 : Boîte de dialogue Commandes de l’interface OSCAR 3. Sélectionnez Activer le balayage dans la boîte de dialogue Commandes. 4. Cliquez sur la case de fermeture X pour fermer la boîte de dialogue Commandes. NOTA : Le balayage commence dès que vous avez sélectionné la case Activer le balayage.
Chapitre 3 : Fonctionnement de la voie locale 41 Accès à la boîte de dialogue Écon. d’écran de l’interface OSCAR : 1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran pour ouvrir la boîte de dialogue Principal. 2. Cliquez sur Config. - Écon. d’écran pour ouvrir la boîte de dialogue Écon. d’écran, comme indiqué à la Figure 3.13. Figure 3.13 : Boîte de dialogue Écon.
42 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Sortie du mode Économiseur d’écran et connexion à la voie locale : 1. Appuyez sur n’importe quelle touche du clavier ou déplacez la souris. 2. Un écran de connexion apparaît si le mode sécurisé de l’économiseur d’écran était activé dans le logiciel DSView. Saisissez votre nom d’utilisateur et votre mot de passe puis cliquez sur OK.
Chapitre 3 : Fonctionnement de la voie locale 43 Définition du paramètre régional d’entrée pour les serveurs Sun : 1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran pour ouvrir la boîte de dialogue Principal. 2. Cliquez sur Config - Clavier pour ouvrir la boîte de dialogue Clavier. Figure 3.14 : Boîte de dialogue Clavier de l’interface OSCAR 3. Sélectionnez un paramètre régional d’entrée et cliquez sur OK pour enregistrer les modifications. 4. Redémarrez les serveurs Sun.
44 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Paramétrage des options Virtual Media Au cours d’une session Virtual Media, vous pouvez définir le comportement du commutateur DSR2035/8035 grâce aux options figurant sous la boîte de dialogue Virtual Media. Le Tableau 3.6 indique les différentes options de configuration des sessions. Tableau 3.
Chapitre 3 : Fonctionnement de la voie locale 45 Figure 3.15 : Boîte de dialogue Virtual Media de l’interface OSCAR 3. Cliquez sur chacune des options pour les activer ou les désactiver. Pour plus d’informations concernant les différents paramètres, reportez-vous au Tableau 3.6 à la page 44. 4. Cliquez sur OK pour accepter les options sélectionnées et pour revenir à la boîte de dialogue Configuration.
46 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Accès à la boîte de dialogue Commandes de l’interface OSCAR : 1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran pour ouvrir la boîte de dialogue Principal. 2. Cliquez sur le bouton Commandes pour ouvrir la boîte de dialogue Commandes, comme indiqué à la Figure 3.16. Figure 3.
Chapitre 3 : Fonctionnement de la voie locale Figure 3.17 : Boîte de dialogue État utilisateur de l’interface OSCAR Déconnexion d’un utilisateur : 1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran pour ouvrir la boîte de dialogue Principal. 2. Cliquez sur Commandes - État utilisateur pour ouvrir la boîte de dialogue État utilisateur, comme indiqué à la Figure 3.17. 3. Cliquez sur la lettre correspondant à l’utilisateur à déconnecter.
48 Guide d’installation et d’utilisation du commutateur DSR2035/8035 4. Cliquez sur OK pour déconnecter l'utilisateur et retourner à la boîte de dialogue État utilisateur. -ouCliquez sur X ou appuyez sur Echap pour quitter la boîte de dialogue sans déconnecter l’utilisateur. NOTA : Si la liste État utilisateur a été modifiée depuis son dernier affichage, le curseur de la souris prend la forme d’un sablier pendant la mise à jour automatique de la liste.
Chapitre 3 : Fonctionnement de la voie locale 49 Affichage des informations relatives à la version : 1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran pour ouvrir la boîte de dialogue Principal. 2. Cliquez sur Commandes - Affichage versions pour ouvrir la boîte de dialogue Version, comme indiqué à la Figure 3.19 à la page 49. La moitié supérieure de la boîte de dialogue donne les versions des sous-systèmes du commutateur DSR2035/8035. Figure 3.
50 Guide d’installation et d’utilisation du commutateur DSR2035/8035 4. Sélectionnez le module DSRIQ que vous souhaitez visualiser et cliquez sur le bouton Version. La boîte de dialogue Version DSRIQ s’affiche. La Figure 3.21 à la page 50 donne un exemple de cette boîte de dialogue. Pour plus d’informations sur le téléchargement du firmware, reportez-vous à l’Annexe A. Figure 3.21 : Boîte de dialogue Version DSRIQ 5. Cliquez sur X pour fermer la boîte de dialogue Version DSRIQ.
51 CHAPITRE 4 Fonctionnement du serveur Web Présentation du serveur Web du DSR2035/8035 En complément de l’interface graphique OSCAR, le commutateur DSR2035/8035 intègre un serveur Web permettant de gérer toutes les tâches de commutation KVM de base. En outre, la mise à niveau vers le logiciel DSView 3 permet de bénéficier de fonctions avancées et de contrôler plusieurs équipements.
52 Guide d’installation et d’utilisation du commutateur DSR2035/8035 À propos de la fenêtre de l’explorateur du DSR La fenêtre de l’explorateur s’affiche après connexion et authentification d’un utilisateur. C’est à partir de cette fenêtre que vous pouvez visualiser le commutateur DSR2035/8035, y accéder et le gérer. Elle permet également de définir les paramètres système et de modifier les paramètres de profil. La Figure 4.
Chapitre 4 : Fonctionnement du serveur Web 53 Tableau 4.1 : Description des zones de la fenêtre de l’explorateur du DSR Lettre Description A Barre d’options supérieure : met en signet une fenêtre du serveur Web du DSR, actualise l’affichage de la fenêtre, imprime une page Web, quitte une session logicielle ou accède à la page d’aide de l’assistance technique d’Avocent. Le nom de l’utilisateur connecté apparaît dans la partie gauche de la barre d’options supérieure.
54 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Utilisation de la barre d’options supérieure Mise en signet d’une fenêtre (avec Internet Explorer uniquement) La barre d’options supérieure de la fenêtre de l’explorateur du DSR comporte une icône de mise en signet appelée bookmark (signet). La mise en signet d’une fenêtre ajoute un lien vers cette fenêtre dans le menu Favorites (Favoris). Sélectionnez ce lien à tout moment pour accéder rapidement à la fenêtre.
Chapitre 4 : Fonctionnement du serveur Web 55 Lancement d’une session KVM Lancement d’une session KVM à partir de l’explorateur du DSR : 1. Dans la barre de navigation latérale de l’explorateur du DSR, sélectionnez Target Devices (Équipements cibles). Une liste des équipements disponibles s’affiche. 2. Cliquez sur le lien KVM session (Session KVM) situé à droite du nom de l’équipement cible auquel vous souhaitez accéder. Le visualiseur vidéo s’affiche.
56 Guide d’installation et d’utilisation du commutateur DSR2035/8035 NOTA : Les dernières versions des firmwares sont disponibles sur le site www.avocent.fr. NOTA : Lors de la mise à jour du commutateur DSR2035/8035, les modules DSRIQ sont automatiquement mis à jour. Pour mettre à jour le firmware du commutateur DSR2035/8035, reportez-vous à l’Annexe A à la page 83 ou à l’aide en ligne du DSView 3. Si nécessaire, il est également possible d’effectuer une mise à jour forcée des modules.
Chapitre 4 : Fonctionnement du serveur Web 57 Les niveaux de préemption vont de 1 à 4, 4 étant le niveau le plus élevé. Par exemple, un utilisateur bénéficiant d’un niveau de préemption 4 peut préempter la session d’autres utilisateurs de niveau 4 ainsi que ceux ayant un niveau de 1, 2 ou 3. Modification du niveau de préemption par défaut (pour l’administrateur uniquement) : 1. 2. Cliquez sur Appliance - Appliance Settings - Ports - OSCAR.
58 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Tableau 4.
Chapitre 4 : Fonctionnement du serveur Web 59 Contrôle de l’alimentation des équipements cibles NOTA : La modification des paramètres du dispositif de contrôle de l’alimentation SPC exige des privilèges d’administrateur. Si un équipement cible est connecté à un dispositif de contrôle de l’alimentation SPC, vous pouvez mettre sous tension, hors tension, ou hors tension puis sous tension cet équipement par l’intermédiaire du serveur Web du DSR. Mise sous tension d’un équipement cible : 1.
60 Guide d’installation et d’utilisation du commutateur DSR2035/8035
61 CHAPITRE 5 Visualiseur vidéo À propos de la fenêtre du visualiseur vidéo Le visualiseur vidéo permet de mener une session de commutation KVM sur les équipements cibles reliés au commutateur DSR. Lors de la connexion à un équipement à l’aide du visualiseur vidéo, le bureau de l’équipement cible s’affiche dans une nouvelle fenêtre, laquelle contient le curseur local et le curseur de l’équipement cible. Le visualiseur vidéo est compatible avec une souris à 3 ou 5 boutons.
62 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Lorsqu’il est lancé depuis les navigateurs Internet Explorer, Mozilla, Netscape ou Firefox, le visualiseur vidéo client nécessite Java, version 1.4.2_04 ou ultérieure. Le serveur Web du DSR télécharge et installe automatiquement le visualiseur vidéo lors de sa première utilisation. NOTA : En revanche, il n’installe pas l’utilitaire Java Resource Engine (JRE). Celui-ci est disponible gratuitement sur le site http:\\www.sun.com.
Chapitre 5 : Visualiseur vidéo Caractéristiques de la fenêtre du visualiseur vidéo La Figure 5.1 présente les zones de la fenêtre du visualiseur vidéo et le Tableau 5.1 à la page 64 les décrit. B C D A H I Figure 5.
64 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Tableau 5.1 : Description de la fenêtre du visualiseur vidéo Lettre Description A Barre de titre : affiche le nom du serveur en cours de visualisation. En mode plein écran, la barre de titre disparaît et le nom du serveur s’affiche entre la barre de menus et la barre d’outils. B Punaise : verrouille l’affichage de la barre de menus et d’outils de manière à ce qu’elle soit toujours visible.
Chapitre 5 : Visualiseur vidéo 65 Modification de la barre d’outils Vous pouvez choisir le délai au bout duquel la barre d’outils est masquée lorsqu’elle se trouve dans l’état affichée/masquée (c’est-à-dire, non verrouillée à l’aide de la punaise). Définition d’une durée de masquage de la barre d’outils : 1. Dans la barre de menus de la fenêtre du visualiseur vidéo, sélectionnez Tools - Session Options -ouCliquez sur le bouton Session Options. La boîte de dialogue correspondante s’affiche. 2.
66 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Réglage de l’affichage Les menus et les boutons de la barre des tâches de la fenêtre du visualiseur permettent de réaliser les tâches suivantes : • Aligner les curseurs de souris • Actualiser l’écran • Activer ou désactiver le mode plein écran. En mode plein écran, l’image est réglée pour que la résolution maximale du bureau soit de 1024 x 768.
Chapitre 5 : Visualiseur vidéo 67 Activation et désactivation du mode plein écran : 1. Pour activer le mode plein écran, cliquez sur le bouton Maximize. -ouSélectionnez View – Full Screen dans la barre de menus de la fenêtre du visualiseur. La fenêtre du bureau disparaît et seul le bureau de l’équipement auquel vous avez accès est visible. L’écran est agrandi jusqu’à un maximum de 1024 x 768. Si le bureau possède une résolution supérieure, un fond noir entoure l’image en plein écran.
68 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Les paramètres d’affichage des fenêtres du visualiseur vidéo sont Best Color Available (Jeu de couleurs optimal) (actualisation plus lente), Best Compression (Compression optimale) (actualisation plus rapide) et une combinaison de Best Color et Best Compression en mode Grayscale (Nuances de gris).
Chapitre 5 : Visualiseur vidéo A B C D E F G 69 H I J K L M N Figure 5.2 : Boîte de dialogue Manual Video Adjust (Réglage vidéo manuel) Tableau 5.
70 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Largeur de la capture d’image, échantillon de pixels/réglage fin, position horizontale de la capture d’image et position verticale de la capture d’image Les commandes de réglage Image Capture Width (Largeur de la capture d’image), Pixel Sampling/ Fine Adjust (Échantillon de pixels/réglage fin), Image Capture Horizontal Position (Position horizontale de la capture d’image) et Image Capture Vertical Position (Position verticale de la captu
Chapitre 5 : Visualiseur vidéo 71 Réglage vidéo automatique NOTA : Vous avez également la possibilité de régler automatiquement les paramètres vidéo en sélectionnant Tools - Automatic Video Adjust dans la barre de menus du visualiseur ou en cliquant sur l’icône Automatic Video Adjust de la barre d’outils. Dans la plupart des cas, vous n’avez pas besoin de modifier les paramètres d’affichage vidéo par défaut. Le système ajuste et optimise automatiquement les paramètres d’affichage.
72 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Curseur distant Curseur local Figure 5.3 : Curseurs local et distant affichés dans la fenêtre du visualiseur vidéo Le mode curseur actif dans le visualiseur s’affiche dans la barre de titre, accompagné du raccourci clavier permettant de quitter le mode curseur simple. Vous pouvez définir ce raccourci clavier dans la boîte de dialogue Session Options.
Chapitre 5 : Visualiseur vidéo 73 Quitter le mode curseur simple : Appuyez sur la touche indiquée dans la barre de titre. Modification du paramètre de curseur : 1. Dans la barre de menus de la fenêtre du visualiseur vidéo, sélectionnez Tools - Session Options -ouCliquez sur le bouton Session Options. La boîte de dialogue correspondante s’affiche. 2. Cliquez sur l’onglet Mouse. 3. Sélectionnez un type de curseur dans le volet Local Cursor. 4. Cliquez sur OK pour enregistrer les paramètres.
74 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Alignement et synchronisation de la souris : Le serveur Web du DSR ne pouvant recevoir de retour d’information de la souris en permanence, il peut arriver que la souris du système relié au DSR et la souris de l’hôte ne soient plus synchrones. Si la souris ou le clavier ne répondent plus correctement, il est parfois nécessaire d’aligner la souris ou de rétablir le repérage.
Chapitre 5 : Visualiseur vidéo 3. Sélectionnez Pass-through all keystrokes in regular window mode (Transmettre toutes les frappes en mode d’affichage normal). 4. Cliquez sur OK pour enregistrer les paramètres. 75 Utilisation de macros Des macros pour les plates-formes Windows et Sun sont préconfigurées sur le serveur Web du DSR. Envoi d’une macro : Sélectionnez Macros - dans la barre de menus du visualiseur vidéo.
76 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Fermeture d’une session du visualiseur vidéo Fermeture d’une session du visualiseur vidéo : Sélectionnez File - Exit (Quitter) dans la barre de menus du visualiseur vidéo.
77 CHAPITRE 6 Utilisation de la voie terminal Menu de la console Chaque commutateur DSR2035/8035 peut être configuré au niveau du commutateur lui-même par l’interface du menu de la console, par l’intermédiaire de la voie SETUP située à l’arrière du commutateur. Toutes les commandes du terminal sont accessibles à partir d’un terminal ou d’un PC exécutant un logiciel d’émulation de terminal. NOTA : Cette méthode n’est PAS recommandée pour le paramétrage des options du commutateur DSR2035/8035.
78 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Figure 6.1 : Menu principal de la console 2. Dans le menu principal de la console, saisissez 1 et appuyez sur Entrée pour accéder à l’option de menu Network Configuration (Configuration réseau), comme indiqué à la Figure 6.2. Figure 6.
Chapitre 6 : Utilisation de la voie terminal 79 3. Saisissez 1 puis appuyez sur la touche Entrée pour régler la vitesse du réseau. Si possible, définissez la connexion manuellement, sans compter sur la fonction d’évaluation automatique. Après avoir appuyé sur la touche Entrée, vous êtes renvoyé au menu Network Configuration. 4. Saisissez 2 puis appuyez sur Entrée pour indiquer si vous utilisez une adresse IP statique ou de type DHCP.
80 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Local Users Accounts NOTA : Lorsque vous utilisez les options d’ajout, de modification ou de suppression d’un utilisateur, la liste des utilisateurs figurant déjà dans la base de données s’affiche. Saisissez N pour afficher la page suivante de la base de données ou P pour afficher la page précédente. Ajout d’un utilisateur dans la base de données du commutateur DSR2035/8035 : 1.
Chapitre 6 : Utilisation de la voie terminal 81 4. Vous êtes invité à entrer le numéro de l’utilisateur que vous voulez supprimer. Tapez le numéro de l’utilisateur puis appuyez sur Entrée. 5. Vous êtes invité à confirmer la suppression de l’utilisateur de la base de données du commutateur DSR2035/8035. Saisissez Y et appuyez sur Entrée pour supprimer l’utilisateur. 6. Saisissez 0 (zéro) pour quitter le menu.
82 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Firmware Management Ce menu comprend la commande FLASH Download (Téléchargement Flash). Pour plus d’informations, reportez-vous à l’Annexe A. Enable Debug Messages Ce menu active l’émission de messages d’état de la console. Il est déconseillé d’utiliser cette commande sans y avoir été invité par l’assistance technique car elle peut réduire de manière significative les performances.
83 A NNEXES Annexes Annexe A : Mises à jour Flash L’option de mise à jour Flash du commutateur DSR2035/8035 vous permet de mettre à jour votre matériel à l’aide des derniers firmwares disponibles. Cette mise à jour peut être effectuée à l’aide du logiciel DSView ou d’un serveur TFTP (Trivial File Transfer Protocol). Une fois la mémoire Flash mise à jour, le commutateur DSR2035/8035 redémarre à chaud, ce qui interrompt toutes les sessions des modules DSRIQ.
84 Guide d’installation et d’utilisation du commutateur DSR2035/8035 6. Saisissez 1 puis appuyez sur la touche Entrée afin d’accéder à la commande FLASH Download. 7. Saisissez l’adresse IP de votre serveur TFTP, puis appuyez sur Entrée. 8. Saisissez le nom du fichier que vous avez téléchargé à partir du site d’Avocent. 9. Confirmez le téléchargement du TFTP en saisissant y ou yes puis en appuyant sur Entrée. 10. Le commutateur DSR2035/8035 lance le processus de mise à jour Flash.
Annexes 85 Annexe B : Utilisation du logiciel DSView via une connexion modem Il est possible de brancher un modem externe sur le commutateur DSR2035/8035. Ce modem peut être utilisé pour accéder au commutateur lorsqu’une connexion Ethernet n’est pas disponible. La connexion par modem ou PPP doit être établie préalablement à toute opération à distance. Elle doit être configurée comme suit : 115200 bit/s, 8 bits, 1 bit d’arrêt, pas de parité ni de contrôle de flux.
86 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Annexe C : Utilisation des modules DSRIQ-SRL Le module DSRIQ-SRL est un convertisseur série/VGA permettant aux équipements compatibles avec VT100 d’être visualisés par la voie locale du commutateur DSR2035/8035 ou à l’aide du logiciel DSView. Les données série proprement dites ne sont pas disponibles mais uniquement visibles.
Annexes 87 • DSR/CD Mode (Mode DSR/CD) : contrôle le mode de fonctionnement des lignes de détection de la porteuse et du commutateur DSR2035/8035. Les options disponibles sont les suivantes : Always on (Toujours activé) et Toggle (Basculer). En mode Toggle, les lignes de détection de la porteuse et le DSR sont désactivés pendant trente secondes puis activés chaque fois qu’un module est sélectionné ou désélectionné. La valeur par défaut est Always on.
88 Guide d’installation et d’utilisation du commutateur DSR2035/8035 • Help Key Sequence (Raccourci de l’écran d’aide) : permet de définir la combinaison de touches affichant le système d’aide en ligne. La combinaison de touches par défaut est Ctrl-F1. • History Key Sequence (Raccourci du mode historique) : permet de définir la combinaison de touches activant le mode History (Historique). La combinaison de touches par défaut est Ctrl-F9.
Annexes 89 Utilisation du mode History Le mode History vous permet d’examiner le tampon de l’historique, qui contient les événements survenus. Le module DSRIQ-SRL dispose d’un tampon de sortie de 240 lignes au minimum (équivalant à 10 écrans). Lorsque le tampon de l’historique arrive à saturation, il insère les nouvelles lignes à la fin et supprime les lignes les plus anciennes situées au début.
90 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Brochage du module DSRIQ-SRL Le Tableau C.1 dresse la liste des broches du module DSRIQ-SRL. Tableau C.
Annexes 91 Annexe D : Câblage UTP Cette annexe explique les différents aspects des supports de connexion. Les performances d’un système de commutation DSR2035/8035 sont tributaires de la qualité des connexions. En effet, un câblage de mauvaise qualité, mal installé ou mal entretenu peut réduire les performances du système DSR. NOTA : Les informations contenues dans cette annexe sont données à titre de référence uniquement.
92 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Installation, maintenance et conseils de sécurité relatifs au câblage La liste suivante détaille des points de sécurité importants à prendre en compte avant toute installation ou maintenance de câbles : • Veillez à ne pas utiliser des câbles CAT 5 de plus de 10 m de long.
Annexes 93 Annexe E : Spécifications techniques Le Tableau E.1 dresse la liste des spécifications technique du commutateur DSR2035/8035. Tableau E.
94 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Tableau E.1 : Spécifications produit du commutateur DSR2035/8035 (suite) Voie pour équipement USB Nombre 5 Type USB 2,0 Hauteur x Largeur x Profondeur 4,37 x 43,18 x 35,75cm ; facteur de forme 1 U Poids 4,5 kg sans les câbles Dimensions Source d’alimentation Puissance d’alimentation en courant alternatif 40 W maximum Tension d’alimentation en courant alternatif 100 à 240 V c.a. Courant nominal d’alimentation (c.a.
Annexes 95 Annexe F : Émulation des touches avancées du clavier Sun Il est possible d’émuler certaines touches d’un clavier Sun (US) de type 5 standard en utilisant des combinaisons de touches sur un clavier PS/2. Pour activer le mode d’émulation de touches avancées du clavier Sun et utiliser ces raccourcis clavier, maintenez les touches Ctrl+Maj+Alt enfoncées, puis appuyez sur la touche Arrêt défil. Le voyant Arrêt défil se met à clignoter. Utilisez la touche indiquée dans le Tableau F.
96 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Par exemple : Pour Stop + A, maintenez les touches Ctrl+Maj+Alt enfoncées et appuyez sur Arrêt défil, puis sur F1 + A. Ces combinaisons de touches fonctionnent avec le module DSRIQ-USB (si votre système Sun est équipé d’une voie USB) ainsi qu’avec les modules DSRIQ-VSN et DSRIQ-WSN Sun. À l’exception de la touche F12, ces raccourcis clavier ne sont pas reconnus sous Microsoft Windows.
Annexes 97 Annexe G : Assistance technique Notre équipe d’assistance technique se tient à votre disposition en cas de problème d’installation ou de fonctionnement susceptible de se produire avec un produit Avocent. Si vous rencontrez une difficulté, suivez la procédure ci-après afin de bénéficier d’une aide le plus rapidement possible. Remédier à un problème : 1. Vérifiez la section correspondante du manuel pour voir si le problème peut être résolu à l’aide des procédures indiquées. 2.
98 Guide d’installation et d’utilisation du commutateur DSR2035/8035
99 INDEX A interface OSCAR 28 mode 38, 39 Accès à distance sécurisé 1 Base de données du commutateur DSR ajouter un utilisateur 80 direct 23 modifier un utilisateur 80 équipement cible 3 supprimer un utilisateur 80 équipements cibles 1 interface OSCAR boîte de dialogue Commandes 46 boîte de dialogue Configuration 29 boîte de dialogue Diffusion 37 boîte de dialogue Écon.
100 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Commutateur DSR 1 Dispositifs SPC contrôle de l’alimentation à partir du visualiseur vidéo 59 caractéristiques 1 configuration réseau 3 éléments fournis 8 DSRIQ installation 5 boîte de dialogue Sélection 49 spécifications produit 93 boîte de dialogue Version 49, 50 voie 32 module 7, 8, 9, 10, 55, 83, 86, 93 connexion 10 Commutateur en cascade 28, 32 Configuration de votre réseau 8 Configuration requise visualiseur vidéo 61 Con
Index I 101 menus 28 modification de l’ordre d’affichage 33 Impr écran 27 navigation 27 interface OSCAR 28 retard d’affichage 26 Indicateur simple clic, Entrée 27 boîte de dialogue 35 accès 35 couleur 36 interface OSCAR 28 K KVM 5 commutateur 1 opaque 36 illustration 7 transparent 36 volume du câblage 2 Installation 5 Interface OSCAR Alt 27 boîte de dialogue Balayage 38 L Logiciel DSView 2, 3, 5, 6, 8, 10, 40, 41, 42, 77, 79, 81, 82, 83, 85, 86 boîte de dialogue Clavier 43 base de données
102 Guide d’installation et d’utilisation du commutateur DSR2035/8035 Mode sécurisé 81 Modem 1, 2, 5, 6, 8, 9, 85 illustration 3 voie 1, 85 Modification d’un utilisateur dans la base de données du commutateur DSR 80 Modification de l’affichage 33 Module DSRIQ-SRL 2, 8, 10, 86, 93 brochage 90 configuration 86, 88 accès à la boîte de dialogue Menu de l’interface OSCAR 33 accès à la boîte de dialogue Noms de l’interface OSCAR 29 activation immédiate de l’économiseur d’écran 42 affichage des informations rel
Index diffusion vers les équipements cibles sélectionnés 37 interruption du mode de balayage 40 lancement du mode de balayage 39 103 S Session KVM voir Visualiseur vidéo Sessions expiration de session du visualiseur vidéo 62 mise à jour du firmware du commutateur DSR via le logiciel DSView 83 Supports de montage en rack 8 mise à jour du firmware du commutateur DSR via le menu de la console 83 Suppression d’un utilisateur dans la base de données du commutateur DSR 80 modification d’un utilisateur dan
104 Guide d’installation et d’utilisation du commutateur DSR2035/8035 expiration de session 62 réglage des options de la souris 71 fermeture d’une session 76 sélection du type de curseur 71 lancement d’une session KVM 62 transmission des frappes au clavier 74 macros 75 Vitesse du réseau 79 modification de la résolution de la fenêtre 65 Voie DSRIQ 7 réglage de l’affichage 66, 68 Voie SPC 1, 9, 93 réglage de la profondeur d’échantillonnage 67
INSTRUCTIONS This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. DANGEROUS VOLTAGE This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
DS R® Switch Installer/User Guide For Technical Support: www.avocent.com/support For models: DSR2035 DSR8035 Avocent Corporation 4991 Corporate Drive Huntsville, Alabama 35805-6201 USA Tel: +1 256 430 4000 Fax: +1 256 430 4031 Avocent International Ltd.