User guide

NOTE: If the DB9 adaptor is used, select the ACS console server pinouts.
ACS console server port pinouts
The following table lists the ACSconsole server serial port pinouts for the MPUIQ-SRL
module.
Pin No. Signal Name Input/Output
1 RTS - Request to Send OUT
2 DTR - Data Terminal Ready OUT
3 TXD - Transmit Data OUT
4 GND - Signal Ground N/A
5 CTS - Clear to Send IN
6 RXD - Receive Data IN
7 DCD/DSR - Data Set Ready IN
8 N/C - Not Connected N/A
Table B.2: ACS Console Server Serial Port Pinouts
Cisco port pinouts
The following table lists the Cisco serial port pinouts for the MPUIQ-SRL module.
Pin No. Signal Name Input/Output
1 CTS - Clear to Send IN
2 DCD/DSR - Data Set Ready IN
3 RXD - Receive Data IN
4 GND - Signal Ground N/A
5 N/C - Not Connected N/A
6 TXD - Transmit Data OUT
7 DTR - Data Terminal Ready OUT
8 RTS - Request to Send OUT
Table B.3: Cisco Serial Port Pinouts
74 MergePoint Unity® Switch Installer/User Guide