Operating instructions

9-17
FITTED EQUIPMENT
Mains Power
This option should only be selected where the
supply voltage of the connection for power
supply corresponds to the value specified on
the data plate. Any difference in values may
result in damage to the appliance.
Gas Operation
The ignition process is activated automatically,
accompanied by a ticking sound approx. 30
sec. Upon successful ignition, the display LED
(C) “Gas” lights yellow. The refrigerator is in
function. Use rotary switch (B) to regulate the
temperature in the main refrigerator
compartment.
1. Set energy selector switch (A) to 230V.
2. Operating display "C" , 230V lights
"green". Appliance is in function.
3. Use rotary switch (B) to regulate
the temperature in the main
refrigerator compartment.
Gas Faults
Remedies:
Set the energy selector switch (A) to position
“OFF”.
1. Is there any gas in the gas bottle?
2. Is the gas bottle valve open?
3. Is the on-board shut-off valve open?
4. Set the main switch (A) to “on”. The
reignition starts again.
If after about 30 seconds the operating
display (C) starts flashing red again, the gas
fault has not been cleared (e.g. air in the gas
pipe).
1. Open the valve of the gas cylinder.
2. Open the shut-off valve to the gas
supply.
3. Set energy selector switch (A) to gas.
4. Set rotary switch (B) to "MAX"
position.
In the event of a gas fault (e.g. gas
cylinder empty), the operating display (C)
flashes yellow.