Operating instructions
9-22
FITTED EQUIPMENT
Failure: The refrigerator does not work on 230V (continued)
Possible cause Action you can take
b) No connection to supply voltage. b) Establish power connection.
c) AES: gas operation despite c) Appliance switches to gas
connection to the supply voltage? operation due to insufficient supply voltage
 (automatically switches back to 230V
operation).
Failure: The refrigerator does not cool sufficiently.
Possible cause Action you can take
a) Inadequate ventilation to a) Check that the ventilation
the unit. grilles are not covered.
b) The thermostat setting is b) Turn the thermostat to a
too low. higher setting.
c) There is too much ice on c) Check that the refrigerator
the condenser. door seals when shut.
d) Too much warm food put d) Let food cool down first.
inside.
e) Appliance running for a e) Wait several hours, check
short time. again.
Maintenance
•Works on gas components and electrical installation may only be carried out by authorised
personnel. We recommend to contact your Dometic Service Centre.
• EN 1949 stipulates that the appliance’s gas equipment and its associated fume system must
be inspected after installation and a certificate issued.
Afterwards a qualified technician must inspect according to EN 1949 every two years and a
certificate issued.
It is the user’s responsibility to arrange for inspections after purchase.
• It is recommended that the gas burner be inspected and cleaned as necessary at least once
a year.
We recommend maintenance following an extended shutdown of the vehicle.
FURTHER DETAILS
Consult the accompanying literature to obtain
the full benefit of your refrigerator.
In the event of failure, contact the Refrigerator
Service Department, details of which can be
found in your Yellow Pages Directory.